Helical tomotherapy dynamic quality assurance

被引:29
|
作者
Balog, John [1 ]
Holmes, Tim
Vaden, Richard
机构
[1] Mohawk Valley Med Phys, Rome, NY 13440 USA
[2] St Agnes HealthCare, Baltimore, MD 21229 USA
[3] EC Rost Oncol LLC, Tallahassee, FL USA
关键词
D O I
10.1118/1.2351952
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multifaceted tomotherapy quality assurance procedure has been developed. This procedure tests most of the features inherent in the tomotherapy Hi-Art device. This includes the megavoltage imaging quality, spatial and temporal accuracy of the dynamic delivery properties, as well as more traditional beam output characteristics. This is accomplished with a specialized multichannel electrometer that measures collected charge every 100 ms and a Virtual Water cylindrical phantom that holds many ion chambers and differing density insert plugs. Both devices are offered with the Hi-Art product. These tests are presented as well as their sensitivity to beam and delivery variations. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3939 / 3950
页数:12
相关论文
共 50 条
  • [1] Helical tomotherapy quality assurance
    Balog, John
    Soisson, Emilie
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S113 - S117
  • [2] Helical tomotherapy quality assurance with ArcCHECK
    Chapman, David
    Barnett, Rob
    Yartsev, Slav
    [J]. MEDICAL DOSIMETRY, 2014, 39 (02) : 159 - 162
  • [3] Quality Assurance Procedures for Helical Tomotherapy
    Haaren, P.
    Althof, V.
    Kramer, D.
    Westendorp, H.
    Minken, A.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [4] Quality assurance of a helical tomotherapy machine
    Fenwick, JD
    Tomé, WA
    Jaradat, HA
    Hui, SK
    James, JA
    Balog, JP
    DeSouza, CN
    Lucas, DB
    Olivera, GH
    Mackie, TR
    Paliwal, BR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13): : 2933 - 2953
  • [5] Mechanical and dosimetric quality assurance for helical tomotherapy
    Ramsey, C. R.
    Gibbons, J.
    Holmes, T.
    Jeong, K.
    Langen, K.
    Low, D.
    Meeks, S.
    Papanikolaou, N.
    Schubert, K.
    Tomsej, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S699 - S699
  • [6] Enhanced efficacy in helical tomotherapy quality assurance
    Goddu, S.
    Mutic, S.
    Chaudhari, S.
    Grigsby, J.
    Low, D.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2248 - 2248
  • [7] Simplified clinical quality assurance for helical tomotherapy
    Grant, W.
    McGary, J.
    Childress, N.
    CravenS, R.
    Krumbach, T.
    Olivera, G.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2561 - 2561
  • [8] Dose reconstruction quality assurance for helical tomotherapy
    Chase, D.
    Ramsey, C.
    Seibert, R.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2256 - 2256
  • [9] Computed radiography for helical tomotherapy quality assurance
    Ramsey, C.
    Harris, C.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2193 - 2193
  • [10] Patient specific quality assurance for helical tomotherapy
    Thomas, S
    MacKenzie, M
    Field, G
    Syme, A
    Fallone, B
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2414 - 2414