Chapman, David [1 ]
Barnett, Rob [1 ]
Yartsev, Slav [1 ]
机构
[1] London Hlth Sci Ctr, London Reg Canc Program, London, ON, Canada
关键词
Helical tomotherapy; Quality assurance; ArcCHECK; QA; UNIT;
D O I
10.1016/j.meddos.2013.12.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an AlSL ion chamber inserted in the central holder. The ArcCHECK was positioned 10 cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquid and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by similar to 2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient. (c) 2014 American Association of Medical Dosimetrists.
引用
收藏
页码:159 / 162
页数:4
相关论文
共 50 条
  • [1] Performance of ArcCHECK based quality assurance in helical tomotherapy with TomoEdge technology
    Yang, B.
    Geng, H.
    Lam, W. W.
    Cheung, K. Y.
    Yu, S. K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S941 - S941
  • [2] Filmless methods for quality assurance of Tomotherapy using ArcCHECK
    Yang, B.
    Wong, W. K. R.
    Geng, H.
    Lam, W. W.
    Ho, Y. W.
    Kwok, W. M.
    Cheung, K. Y.
    Yu, S. K.
    [J]. MEDICAL PHYSICS, 2017, 44 (01) : 7 - 16
  • [3] Quality Assurance on Helical Tomotherapy Treatments with small target and high modulation factor using ArcCHECK
    Kong, C. W.
    Ho, Y. W.
    Geng, H.
    Lam, W. W.
    Chiu, T. L.
    Wong, W. K.
    Yu, S. K.
    Cheung, K. Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S759 - S759
  • [4] Helical tomotherapy quality assurance
    Balog, John
    Soisson, Emilie
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S113 - S117
  • [5] Helical tomotherapy dynamic quality assurance
    Balog, John
    Holmes, Tim
    Vaden, Richard
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3939 - 3950
  • [6] Quality Assurance Procedures for Helical Tomotherapy
    Haaren, P.
    Althof, V.
    Kramer, D.
    Westendorp, H.
    Minken, A.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [7] Quality assurance of a helical tomotherapy machine
    Fenwick, JD
    Tomé, WA
    Jaradat, HA
    Hui, SK
    James, JA
    Balog, JP
    DeSouza, CN
    Lucas, DB
    Olivera, GH
    Mackie, TR
    Paliwal, BR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13): : 2933 - 2953
  • [8] Mechanical and dosimetric quality assurance for helical tomotherapy
    Ramsey, C. R.
    Gibbons, J.
    Holmes, T.
    Jeong, K.
    Langen, K.
    Low, D.
    Meeks, S.
    Papanikolaou, N.
    Schubert, K.
    Tomsej, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S699 - S699
  • [9] Enhanced efficacy in helical tomotherapy quality assurance
    Goddu, S.
    Mutic, S.
    Chaudhari, S.
    Grigsby, J.
    Low, D.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2248 - 2248
  • [10] Simplified clinical quality assurance for helical tomotherapy
    Grant, W.
    McGary, J.
    Childress, N.
    CravenS, R.
    Krumbach, T.
    Olivera, G.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2561 - 2561