Helical tomotherapy dynamic quality assurance

被引:29
|
作者
Balog, John [1 ]
Holmes, Tim
Vaden, Richard
机构
[1] Mohawk Valley Med Phys, Rome, NY 13440 USA
[2] St Agnes HealthCare, Baltimore, MD 21229 USA
[3] EC Rost Oncol LLC, Tallahassee, FL USA
关键词
D O I
10.1118/1.2351952
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multifaceted tomotherapy quality assurance procedure has been developed. This procedure tests most of the features inherent in the tomotherapy Hi-Art device. This includes the megavoltage imaging quality, spatial and temporal accuracy of the dynamic delivery properties, as well as more traditional beam output characteristics. This is accomplished with a specialized multichannel electrometer that measures collected charge every 100 ms and a Virtual Water cylindrical phantom that holds many ion chambers and differing density insert plugs. Both devices are offered with the Hi-Art product. These tests are presented as well as their sensitivity to beam and delivery variations. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:3939 / 3950
页数:12
相关论文
共 50 条
  • [41] TomoEQA: Dose verification for patient-specific quality assurance in helical tomotherapy using an exit detector
    Han, Min Cheol
    Chang, Kyung Hwan
    Kim, Jihun
    Han, Su Chul
    Park, Kwangwoo
    Kim, Dong Wook
    Kim, Hojin
    Kim, Jin Sung
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 1 - 6
  • [42] Experience with Helical TomoTherapy Commissioning and Quality Assurance of Twin Peaks Linac vs. Earlier Models
    Movahed, A.
    Rabbani, B.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [43] Quality Assurance of Helical Tomotherapy Stereotactic Radiosurgery Treatment Using 4D Detector Array
    Lam, W.
    Geng, H.
    Kong, C.
    Cheung, K.
    Yu, S.
    Chiu, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S577 - S578
  • [44] Film-free quality assurance in tomotherapy
    Jakob, S.
    Boettcher, M.
    Yango, A.
    Muedder, T.
    Schoroth, F.
    Schueller, H.
    Holz, D.
    Garbe, S.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 138 - 138
  • [45] MOSFET detectors in quality assurance of tomotherapy treatments
    Cherpak, Amanda
    Studinski, Ryan C. N.
    Cygler, Joanna E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 86 (02) : 242 - 250
  • [46] Quality Assurance Check on Tomotherapy and Precalculation of Time
    Sriramulu, H. Erra
    Sharma, A.
    Muruganandham, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3394 - +
  • [47] A comparison of tools for Delivery Quality Assurance in TomoTherapy
    Santos, T.
    Ventura, T.
    Mateus, J.
    Capela, M.
    Lopes, M. D. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S964 - S964
  • [48] Daily quality assurance tool and procedures for tomotherapy
    Jursinic, P. A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S702 - S703
  • [49] Mosfet detectors in quality assurance of tomotherapy treatments
    Cherpak, A. J.
    Studinski, R. C. N.
    Cygler, J. E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S55 - S55
  • [50] Dynamic Delivery Techniques for Helical Tomotherapy Treatment
    Chen, Y.
    Lu, W.
    Chen, M.
    Chen, Q.
    Schnarr, E.
    Reitz, G.
    Henderson, D.
    Ruchala, K. J.
    Olivera, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S122 - S122