Predictive dose accumulation for HN adaptive radiotherapy

被引:6
|
作者
Lee, Donghoon [1 ]
Zhang, Pengpeng [1 ]
Nadeem, Saad [1 ]
Alam, Sadegh [1 ]
Jiang, Jue [1 ]
Caringi, Amanda [1 ]
Allgood, Natasha [1 ]
Aristophanous, Michalis [1 ]
Mechalakos, James [1 ]
Hu, Yu-Chi [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 23期
关键词
parotid gland; displacement field; adaptive radiotherapy; RADIATION-THERAPY; DEFORMABLE REGISTRATION; NECK-CANCER; PAROTID-GLANDS; HEAD; STRATEGIES; VOLUME;
D O I
10.1088/1361-6560/abbdb8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During radiation therapy (RT) of head and neck (HN) cancer, the shape and volume of the parotid glands (PG) may change significantly, resulting in clinically relevant deviations of delivered dose from the planning dose. Early and accurate longitudinal prediction of PG anatomical changes during the RT can be valuable to inform decisions on plan adaptation. We developed a deep neural network for longitudinal predictions using the displacement fields (DFs) between the planning computed tomography (pCT) and weekly cone beam computed tomography (CBCT). Sixty-three HN patients treated with volumetric modulated arc were retrospectively studied. We calculated DFs between pCT and week 1-3 CBCT by B-spline and Demon deformable image registration (DIR). The resultant DFs were subsequently used as input to our novel network to predict the week 4 to 6 DFs for generating predicted weekly PG contours and weekly dose distributions. For evaluation, we measured dice similarity (DICE), and the uncertainty of accumulated dose. Moreover, we compared the detection accuracies of candidates for adaptive radiotherapy (ART) when the trigger criteria were mean dose difference more than 10%, 7.5%, and 5%, respectively. The DICE of ipsilateral/contralateral PG at week 4 to 6 using the prediction model trained with B-spline were 0.81 +/- 0.07/0.81 +/- 0.04 (week 4), 0.79 +/- 0.06/0.81 +/- 0.05 (week 5) and 0.78 +/- 0.06/0.82 +/- 0.02 (week 6). The DICE with the Demons model were 0.78 +/- 0.08/0.82 +/- 0.03 (week 4), 0.77 +/- 0.07/0.82 +/- 0.04 (week 5) and 0.75 +/- 0.07/0.82 +/- 0.02 (week 6). The dose volume histogram (DVH) analysis with the predicted accumulated dose showed the feasibility of predicting dose uncertainty due to the PG anatomical changes. The AUC of ART candidate detection with our predictive model was over 0.90. In conclusion, the proposed network was able to predict future anatomical changes and dose uncertainty of PGs with clinically acceptable accuracy, and hence can be readily integrated into the ART workflow.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Dose Deformation and Accumulation for Adaptive Radiotherapy in Nasopharyngeal Carcinoma
    Zhou, Lu
    Zhang, Shuxu
    Yuan, Kehong
    Wang, Linjing
    Peng, Yingying
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 397 - 401
  • [2] Commissioning and clinical implementation of dose accumulation and adaptive radiotherapy
    Brock, K.
    McCulloch, M.
    Cazoulat, G.
    Ohrt, A.
    Balter, P.
    Bahig, H.
    Ping, S.
    Mohamed, A.
    Elhalawani, H.
    Elgohari, B.
    Frank, S.
    Wang, J.
    Rosenthal, D.
    Fuller, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1108 - S1108
  • [3] Clinical Implementation of Daily Dose Accumulation and Adaptive Radiotherapy
    Brock, K. K.
    Ohrt, A. N.
    Gryshkevych, S.
    McCulloch, M. M.
    Cazoulat, G.
    Mohamed, A. S.
    He, R.
    Balter, P.
    Ohrt, J.
    Svensson, S.
    Fuller, C. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E371 - E372
  • [4] Deformable dose accumulation is required for adaptive radiotherapy practice
    Zhong, Hualiang
    Pursley, Jennifer M.
    Rong, Yi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08):
  • [5] Toward Predictive Dose Accumulation - Predicting Displacement Fields of Anatomical Change in Head-And-Neck Adaptive Radiotherapy
    Hu, Y.
    Zhang, P.
    Wang, C.
    Mechalakos, J.
    Mageras, G.
    Lee, N.
    Deasy, J.
    Hunt, M.
    MEDICAL PHYSICS, 2019, 46 (06) : E423 - E423
  • [6] Automated Dose Accumulation for Online Adaptive Radiotherapy of Head and Neck Cancers
    Gros, S.
    Santhanam, A.
    Elliott, D.
    Roeske, J.
    Patel, R.
    Kang, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E582 - E582
  • [7] Impact of CT Selection on Dose Accumulation in Adaptive Radiotherapy for Head and Neck Patients
    Choulilitsa, Evangelia
    Smolders, Andreas Johan
    Bachtiary, Barbara
    Weber, Damien Charles
    Lomax, Antony John
    Albertini, Francesca
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4308 - S4311
  • [8] Development of a deformable dosimetric phantom to verify dose accumulation algorithms for adaptive radiotherapy
    Zhong, Hualiang
    Adams, Jeffrey
    Glide-Hurst, Carri
    Zhang, Hualin
    Li, Haisen
    Chetty, Indrin J.
    JOURNAL OF MEDICAL PHYSICS, 2016, 41 (02) : 106 - 114
  • [9] ADAPTIVE RADIOTHERAPY BY PREDICTIVE BIOLOGICAL MARKERS
    Roedel, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S34 - S34
  • [10] CBCT Padding for Full Field of View Daily Dose Accumulation and Head and Neck Adaptive Radiotherapy
    Brock, K.
    Ohrt, A.
    Cazoulat, G.
    McCulloch, M.
    Balter, P.
    Ohrt, J.
    Svensson, S.
    Nilsson, R.
    Andersson, S.
    Mohamed, A.
    Bahig, H.
    Ding, Y.
    Wang, J.
    McDonald, B.
    Yang, J.
    Vedam, S.
    Elgohari, B.
    Sen, A.
    Fuller, C.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S900 - S901