摘要
The need for continuous monitoring of polychlorinated biphenyls (PCBs) has necessitated the development of analytical techniques that are sensitive and selective with minimal reagent requirement. In light of this, we developed a column for clean-up of soil and sediment extracts, which is less demanding in terms of the amount of solvent and sorbent. The dual-layer column consists of acidified silica gel and molecularly imprinted polymers (MIPs). MIPs were synthesized via aqueous suspension polymerization using PCB 15 as the dummy template, 4-vinylpyridine as the functional monomer and ethylene glycol dimethacrylate as the cross-linker and the obtained particles characterized via SEM, BET, and batch rebinding assays. Pre-concentration of the spiked real-world water sample using MISPE gave recoveries between 85.2 and 104.4% (RSD < 8.69). On the other hand, the specific dual-layer column designed for clean-up of extracts from complex matrices provided recoveries of 91.6-102.5% (RSD < 4%) for spiked soil, which was comparable to clean-up using acidified silica (70.4-90.5%; RSD < 3.72%) and sulfoxide modified silica (89.7-103.0%; RSD < 13.0%). However, the polymers were reusable maintaining recoveries of 79.8-111.8% after 30 cycles of regeneration and re-use, thereby availing a cost-effective clean-up procedure for continuous monitoring of PCBs. Method detection limits were 0.01-0.08 ng g(-1) and 0.002-0.01 ng mL(-1) for solid matrices and water, respectively.
引用
收藏
页码:2101 / 2109
页数:9
相关论文
共 50 条
  • [21] Determination of indicator polychlorinated biphenyls in vegetable oils by double clean-up- gas chromatography
    Ding Liping
    Cai Chunping
    Wang Danhong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (11) : 1266 - 1270
  • [22] Determination of ochratoxin A in wheat after clean-up through a DNA aptamer-based solid phase extraction column
    De Girolamo, Annalisa
    McKeague, Maureen
    Miller, J. David
    DeRosa, Maria C.
    Visconti, Angelo
    FOOD CHEMISTRY, 2011, 127 (03) : 1378 - 1384
  • [23] Simultaneous extraction and clean-up of polychlorinated biphenyls and their metabolites from small tissue samples using pressurized liquid extraction
    Kania-Korwel, Izabela
    Zhao, Hongxia
    Norstrom, Karin
    Li, Xueshu
    Hornbuckle, Keri C.
    Lehmler, Hans-Joachim
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1214 (1-2) : 37 - 46
  • [24] Immunoaffinity column clean-up and thin layer chromatography for determination of ochratoxin A in green coffee
    Santos, EA
    Vargas, EA
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2002, 19 (05): : 447 - 458
  • [25] Immunoaffinity column as clean-up tool for determination of trace amounts of microcystins in tap water
    Tsutsumi, T
    Nagata, S
    Hasegawa, A
    Ueno, Y
    FOOD AND CHEMICAL TOXICOLOGY, 2000, 38 (07) : 593 - 597
  • [26] Dounreay pulsed column clean-up now completed
    不详
    PROFESSIONAL ENGINEERING, 2009, 22 (07) : 48 - 48
  • [27] Validation of an HPLC Analytical Method Coupled to a Multifunctional Clean-up Column for the Determination of Deoxynivalenol
    Yoshiko Sugita-Konsihi
    Toshitsugu Tanaka
    Setsuko Tabata
    Masahiro Nakajima
    Masanori Nouno
    Yoko Nakaie
    Takao Chonan
    Mitsutoshi Aoyagi
    Nobuyuki Kibune
    Kazutoshi Mizuno
    Eiichi Ishikuro
    Naoki Kanamaru
    Masatoshi Minamisawa
    Norio Aita
    Masayo Kushiro
    Kenji Tanaka
    Kosuke Takatori
    Mycopathologia, 2006, 161 : 239 - 243
  • [28] Determination of moniliformin using SAX column clean-up and HPLC/DAD-detection
    A. Parich
    L. Schuch Boeira
    S. Perez Castro
    R. Krska
    Mycotoxin Research, 2003, 19 (2) : 203 - 206
  • [29] Validation of an HPLC analytical method coupled to a multifunctional clean-up column for the determination of deoxynivalenol
    Sugita-Konsihi, Y
    Tanaka, T
    Tabata, S
    Nakajima, M
    Nouno, M
    Nakaie, Y
    Chonan, T
    Aoyagi, M
    Kibune, N
    Mizuno, K
    Ishikuro, E
    Kanamaru, N
    Minamisawa, M
    Aita, N
    Kushiro, M
    Tanaka, K
    Takatori, K
    MYCOPATHOLOGIA, 2006, 161 (04) : 239 - 243
  • [30] An improved clean-up strategy for simultaneous analysis of polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF), and polychlorinated biphenyls (PCB) in fatty food samples
    Catherine Pirard
    Jean-François Focant
    Edwin De Pauw
    Analytical and Bioanalytical Chemistry, 2002, 372 : 373 - 381