Validation of an HPLC analytical method coupled to a multifunctional clean-up column for the determination of deoxynivalenol

被引:40
|
作者
Sugita-Konsihi, Y
Tanaka, T
Tabata, S
Nakajima, M
Nouno, M
Nakaie, Y
Chonan, T
Aoyagi, M
Kibune, N
Mizuno, K
Ishikuro, E
Kanamaru, N
Minamisawa, M
Aita, N
Kushiro, M
Tanaka, K
Takatori, K
机构
[1] Natl Inst Hlth Sci, Setagaya Ku, Tokyo 1588501, Japan
[2] Tokyo Metropolitan Inst Publ Hlth, Tokyo, Japan
[3] Kobe Inst Hlth, Kobe, Hyogo, Japan
[4] Nagoya City Publ Hlth Res Inst, Nagoya, Aichi, Japan
[5] Yokohama Quarantine Stn, Yokohama, Kanagawa, Japan
[6] Kobe Quarantine Stn, Kobe, Hyogo, Japan
[7] Hokkaido Inst Publ Hlth, Hokkaido, Japan
[8] Japan Food Res Labs, Osaka Branch, Osaka, Japan
[9] Fertilizer & Feed Instpect Serv, Tokyo, Japan
[10] Japan Grain Inspect Assoc, Tokyo, Japan
[11] Fertilizer & Feed Inspect Serv, Sendai Branch, Sendai, Miyagi, Japan
[12] Natl Food Res Inst, Tokyo, Japan
关键词
deoxynivalenol (DON); HPLC; inter-laboratory study; multifunctional clean-up column; validation; wheat;
D O I
10.1007/s11046-006-0260-1
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
To evaluate a method using a multifunctional clean-up column coupled with high performance liquid chromatography as an official analytical method for the determination of deoxynivalenol in wheat used as food or feed, an inter-laboratory study was performed in 12 laboratories using four naturally contaminated wheat samples and one spiked sample. The relative standard deviations for repeatability (RSDr) and reproducibility (RSDR) of naturally contaminated wheat were in the range 5.8-11.3% and 12.0-20.7%, respectively. The HORRAT was less than 1.0 in each sample. From the spiking test, the recovery rate, RSDr, RSDR and HORRAT value were 100.0%, 11.2%, 10.3% and 0.5, respectively. The limit of quantification is 0.10 mg/kg from the range obtained in a linear calibration. Thus, it should be useful as a sensitive and validated analytical method for the determination of deoxynivalenol in wheat intended for use in food and feed.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 50 条
  • [1] Validation of an HPLC Analytical Method Coupled to a Multifunctional Clean-up Column for the Determination of Deoxynivalenol
    Yoshiko Sugita-Konsihi
    Toshitsugu Tanaka
    Setsuko Tabata
    Masahiro Nakajima
    Masanori Nouno
    Yoko Nakaie
    Takao Chonan
    Mitsutoshi Aoyagi
    Nobuyuki Kibune
    Kazutoshi Mizuno
    Eiichi Ishikuro
    Naoki Kanamaru
    Masatoshi Minamisawa
    Norio Aita
    Masayo Kushiro
    Kenji Tanaka
    Kosuke Takatori
    Mycopathologia, 2006, 161 : 239 - 243
  • [2] Determination of aflatoxins in animal feeds by HPLC with multifunctional column clean-up
    Khayoon, Wejdan Shakir
    Saad, Bahruddin
    Yan, Chew Bee
    Hashim, Nor Hasani
    Ali, Abdussalam Salhin Mohamed
    Salleh, Muhammad Idiris
    Salleh, Baharuddin
    FOOD CHEMISTRY, 2010, 118 (03) : 882 - 886
  • [3] New method of citrinin determination by HPLC after polyamide column clean-up
    Meister, U
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2004, 218 (04) : 394 - 399
  • [4] New method of citrinin determination by HPLC after polyamide column clean-up
    Ute Meister
    European Food Research and Technology, 2004, 218 : 394 - 399
  • [5] Optimisation of the determination of deoxynivalenol in wheat flour by HPLC and a comparison of four clean-up procedures
    Moazami, E. F.
    Jinap, S.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (09): : 1290 - 1297
  • [6] A collaborative study of an HPLC method for determination of ochratoxin A in wheat using immunoaffinity column clean-up
    Scudamore, KA
    MacDonald, SJ
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 1998, 15 (04): : 401 - 410
  • [7] Validation and robustness testing of a HPLC method for the determination of avermectins and moxidectin in animal liver samples using an alumina column clean-up
    Danaher, M
    O'Keeffe, M
    Glennon, JD
    ANALYST, 2000, 125 (10) : 1741 - 1744
  • [8] Comparison of different clean-up procedures for the analysis of deoxynivalenol in cereal-based food and validation of a reliable HPLC method
    Klötzel, M
    Schmidt, S
    Lauber, U
    Thielert, G
    Humpf, HU
    CHROMATOGRAPHIA, 2005, 62 (1-2) : 41 - 48
  • [9] Comparison of Different Clean-Up Procedures for the Analysis of Deoxynivalenol in Cereal-Based Food and Validation of a Reliable HPLC Method
    M. Klötzel
    S. Schmidt
    U. Lauber
    G. Thielert
    H. -U. Humpf
    Chromatographia, 2005, 62 : 41 - 48
  • [10] The comparison of two clean-up procedures, multifunctional column and immunoaffinity column, for HPLC determination of ochratoxin A in cereals, raisins and green coffee beans
    Sugita-Konishi, Yoshiko
    Tanaka, Toshitugu
    Nakajima, Masahiro
    Fujita, Kazuhiro
    Norizuki, Hiroko
    Mochizuki, Naoki
    Takatori, Kosuke
    TALANTA, 2006, 69 (03) : 650 - 655