Short-term mechanical circulatory support with the Impella 5.0 device for cardiogenic shock at La Pitie-Salpetriere

被引:37
|
作者
Mastroianni, Ciro [1 ,2 ,3 ]
Bouabdallaoui, Nadia [1 ,2 ,3 ]
Leprince, Pascal [1 ,2 ,3 ]
Lebreton, Guillaume [1 ,2 ,3 ]
机构
[1] Univ Paris 06, Dept Thorac & Cardiovasc Surg, F-75252 Paris 05, France
[2] La Pitie Salpetriere Hosp, AP HP, Paris, France
[3] La Pitie Salpetriere Hosp, Dept Thorac & Cardiovasc Surg, 47-83 Blvd Hop, Paris, France
关键词
Cardiogenic shock; Impella LP 5.0; right axillary artery insertion; device related complications; VENTRICULAR ASSIST DEVICE; AXILLARY ARTERY; HEART-FAILURE;
D O I
10.1177/2048872616633877
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Cardiogenic shock carries a high mortality rate despite aggressive medical treatment. The Impella (R) Recover (R) LP 5.0 Support System is a microaxial minimally invasive ventricular assist device designed for short-term mechanical circulatory support in low cardiac output states. The aim of this study is to assess the safety of the Impella 5.0 device, using the right axillary artery approach, in cardiogenic shock managed at La Pitie-Salpetriere Hospital. Methods: Since December 2010 and during a period of 14 months, 14 highly selected patients underwent surgical implantation of an Impella 5.0 device for cardiogenic shock. Demographics, preoperative and postoperative data were retrospectively collected from La Pitie-Salpetriere computerized medical charts. Responders to Impella support were defined as patients with rapid improvement in haemodynamic condition and biological profile. Patients who had no signs of cardiac recovery after two weeks of mechanical support were considered for heart transplantation or long-term left ventricular assist device implantation. Results: Patients were predominantly male (78.5%) with a mean age of 6415. Short-term circulatory support was indicated for cardiogenic shock in the setting of acute coronary syndromes (n=7; 50%), postcardiotomy cardiac dysfunctions (n=6; 43%) and anthracycline-induced dilated cardiomyopathy (n=1; 7%). After a mean support time of 8.5 days, six patients (42.8%) were successfully weaned and four (28.5%) were switched to a long-term left ventricular assist device. No major bleeding, arm ischaemia, ventricular arrhythmia or severe haemolysis was noted. We report two cases (14%) of pump thrombosis, four cases of device displacement with the need of pump repositioning and one case (7%) of infection at the insertion site. Thirty-day mortality was 35.7%. Long-term overall mortality rate at six months, one year and two years was 42.8, 42.8 and 42.8%, respectively. Conclusions: The Impella 5.0 device surgically inserted through the axillary artery is a valuable minimally invasive short-term circulatory support in cardiogenic shock of various aetiologies.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [41] Clinical Impact of Advances of Short-Term Mechanical Circulatory Support Devices and Therapeutic Strategies in Patients With Cardiogenic Shock
    Watanabe, Takuya
    Seguchi, Osamu
    Fukushima, Satsuki
    Fujita, Tomoyuki
    Tsukamoto, Yasumasa
    CIRCULATION, 2022, 146
  • [42] Palliative Care Consultation in Cardiogenic Shock Requiring Short-Term Mechanical Circulatory Support: A Retrospective Cohort Study
    Nakagawa, Shunichi
    Garan, Arthur R.
    Takeda, Koji
    Takayama, Hiroo
    Topkara, Veli K.
    Yuzefpolskaya, Melana
    Yuill, Lauren
    Lin, Susan X.
    Colombo, Paolo C.
    Naka, Yoshifumi
    Blinderman, Craig D.
    JOURNAL OF PALLIATIVE MEDICINE, 2019, 22 (04) : 432 - 436
  • [43] SHORT-TERM MORTALITY AND USE OF MECHANICAL CIRCULATORY SUPPORT IN WOMEN WITH CARDIOGENIC SHOCK: SEX-RELATED DIFFERENCES
    Mubasher, Mahmood
    Syed, Tausif
    Hanafi, Amir
    Salama, Amr
    Nadkarni, Ninad
    Alotaki, Erfan
    Hall, Cameron
    Rao, Mohan
    Abdullah, Abdullah Sayied
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 772 - 772
  • [44] Use of short-term mechanical circulatory support and predictors of outcome in patients with cardiogenic shock secondary to fulminant myocarditis
    Couto-Mallon, D.
    Nicolas Manito-Lorite, N. M. L.
    Josep Roca-Elias, J. R. E.
    Carlos Sanchez-Salado, J. C. S. S. Jose
    Albert Ariza-Sole, A. A. S.
    Joel Salazar-Mendiguchia, J. S. M.
    Albert Miralles-Cassina, A. M. C.
    Fabrizio Sbraga, F. S.
    Angel Cequier-Fillat, A. C. F.
    Jose Gonzalez-Costello, J. G. C.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 132 - 133
  • [45] The North American perspective on short-term mechanical circulatory support for cardiogenic shock: could differences in policy be driving differences in temporary mechanical circulatory support use?
    van Diepen, Sean
    Arias-Mendoza, Alexandra
    Sinha, Shashank S.
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2023, 12 (07) : 486 - 489
  • [46] The Impella 5.5 as a Short Term Mechanical Circulatory Support Device in High Risk Cardiac Surgery
    Patel, N. D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2021, 40 (04): : S407 - S407
  • [47] Short-term mechanical management of cardiogenic shock
    Brown J.L.
    Bogaev R.C.
    O'Connell J.
    Current Treatment Options in Cardiovascular Medicine, 2011, 13 (4) : 343 - 353
  • [48] Predictors of survival and ability to wean from short-term mechanical circulatory support device following acute myocardial infarction complicated by cardiogenic shock
    Garan, A. Reshad
    Eckhardt, Christina
    Takeda, Koji
    Topkara, Veli K.
    Clerkin, Kevin
    Fried, Justin
    Masoumi, Amirali
    Demmer, Ryan T.
    Trinh, Pauline
    Yuzefpolskaya, Melana
    Naka, Yoshifumi
    Burkhoff, Dan
    Kirtane, Ajay
    Colombo, Paolo C.
    Takayama, Hiroo
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2018, 7 (08) : 755 - 765
  • [49] IMPACT OF CARDIOGENIC SHOCK WITH OR WITHOUT MECHANICAL CIRCULATORY SUPPORT ON SHORT-TERM AND LONG-TERM SURVIVAL IN HEART FAILURE HOSPITALIZATIONS
    Smith, Lavone
    Peters, Anthony
    Corotto, Paul
    Moss, Travis
    Bilchick, Kenneth
    Mazimba, Sula
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 866 - 866
  • [50] High-output mechanical circulatory support devices for cardiogenic shock after myocardial infarction: ECMO versus Impella CP/5.0
    Karami, M.
    Den Uil, C. A.
    Ouweneel, D. M.
    Scholte, N. T. B.
    Engstrom, A. E.
    Henriques, J. P. Simao
    EUROPEAN HEART JOURNAL, 2018, 39 : 11 - 12