Direct injection versus liquid-liquid extraction for plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry

被引:0
|
作者
Jemal, M [1 ]
Huang, M [1 ]
Jiang, XH [1 ]
Mao, Y [1 ]
Powell, ML [1 ]
机构
[1] Bristol Myers Squibb Pharmaceut Res Inst, Bioanalyt Res Metab & Pharmacokinet, New Brunswick, NJ 08903 USA
关键词
D O I
10.1002/(SICI)1097-0231(19991115)13:21<2125::AID-RCM763>3.0.CO;2-H
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Direct injection versus liquid-liquid extraction for post-dose human plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry (LC/MS/MS) have been studied using a drug candidate compound. For the direct-injection method, an Oasis(R) HLB column (1 x 50 mm, 30 mu m) was used as the on-line extraction column and a conventional Waters symmetry C18 column (3.9 x 50 mm, 5 mu m) was used as the analytical column. Each plasma sample (100 mu L) was mixed with 100 mu L of a working solution of the internal standard in aqueous 0.05 M ammonium acetate (pH 6.9), and portions (10 mu L) of these samples were then injected into the LC/MS/MS system. For the liquid-liquid extraction method, a YMC Basic C18 column (2.0 x 50 mm, 5 mu m) was used as the analytical column. Each sample (0.5 mL) was extracted with methyl tert-butyl ether and the extract was reconstituted and injected into the LC/MS/MS system. The total analysis time for both methods was 2.0 min per sample. The accuracy, inter-day precision and intra-day precision obtained from the quality control samples were within 8% for both methods. The analysis results of post-dose human plasma samples showed that the deviations of 91% of the concentrations obtained using the direct-injection method were within +/-20% from the concentrations obtained using the liquid-liquid extraction method, and the overall average percentage deviation was -1.5%. The results showed that the two methods were equivalent in terms of total chromatographic run time, accuracy and precision, However, for a batch of 100 samples, the sample preparation time for the direct-injection method was only about 25% of the time required for liquid-liquid extraction, This decrease in sample preparation time resulted in the doubling of the overall sample analysis throughput, Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:2125 / 2132
页数:8
相关论文
共 50 条
  • [41] Direct liquid chromatography tandem mass spectrometry analysis of amino acids in human plasma
    Desmons, Aurore
    Thioulouse, Elizabeth
    Hautem, Jean-Yves
    Saintier, Anne
    Baudin, Bruno
    Lamaziere, Antonin
    Netter, Claude
    Moussa, Fathi
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1622 (1622)
  • [42] Determination of pesticide residues in ginseng by dispersive liquid-liquid microextraction and ultra high performance liquid chromatography-tandem mass spectrometry
    Chen, Lina
    Yin, Lihua
    Song, Fengrui
    Liu, Zhiqiang
    Zheng, Zhong
    Xing, Junpeng
    Liu, Shuying
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 917 : 71 - 77
  • [43] Application of Dispersive Liquid-Liquid Microextraction Followed by High-Performance Liquid Chromatography/Tandem Mass Spectrometry Analysis to Determine Tetrabromobisphenol A in Complex Matrices
    Macedo, Williane Vieira
    Bernegossi, Aline Christine
    Sabatini, Carolina Aparecida
    Corbi, Juliano Jose
    Zaiat, Marcelo
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2020, 39 (11) : 2147 - 2157
  • [44] Supercritical fluid chromatography tandem mass spectrometry employed with evaporation-free liquid-liquid extraction for the rapid analysis of cinnarizine in rat plasma
    Zhang, Jiaming
    Zhang, Yu
    Liu, Xiaoyu
    Xu, Xiaolan
    Li, Yingchao
    Zhang, Tianhong
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (04) : 968 - 975
  • [45] Determination of serum aldosterone by liquid chromatography and tandem mass spectrometry: a liquid-liquid extraction method for the ABSCIEX API-5000 mass spectrometry system
    Van der Gugten, Jessica Grace
    Dubland, Joshua
    Liu, Hua-Fen
    Wang, Alex
    Joseph, Christine
    Holmes, Daniel T.
    JOURNAL OF CLINICAL PATHOLOGY, 2012, 65 (05) : 457 - 462
  • [46] High-throughput salting-out assisted liquid-liquid extraction with acetonitrile for the determination of anandamide in plasma of hemodialysis patients with liquid chromatography tandem mass spectrometry
    Xiong, Xin
    Zhang, Lei
    Cheng, Litao
    Mao, Wei
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (09) : 1317 - 1324
  • [47] Application of dispersive liquid-liquid extraction followed by rapid and direct mass spectrometry analysis to evaluate parabens in high salinity water sample
    Jiang, Yanxiao
    Bian, Xiaoyuan
    Zhang, Meng
    Zhang, Hong
    Yu, Kai
    Kan, Guangfeng
    Feng, Yu
    Wang, Xiaofei
    Song, Daqian
    Jiang, Jie
    MICROCHEMICAL JOURNAL, 2023, 194
  • [48] Assessment of perfluoroalkyl substances in placenta by coupling salt assisted liquid-liquid extraction with dispersive liquid-liquid microextraction prior to liquid chromatography-tandem mass spectrometry
    Vela-Soria, F.
    Garcia-Villanova, J.
    Mustieles, V
    de Haro, T.
    Antignac, J. P.
    Fernandez, M. F.
    TALANTA, 2021, 221
  • [49] Assessment of perfluoroalkyl substances in placenta by coupling salt assisted liquid-liquid extraction with dispersive liquid-liquid microextraction prior to liquid chromatography-tandem mass spectrometry
    Vela-Soria, F.
    García-Villanova, J.
    Mustieles, V.
    de Haro, T.
    Antignac, J.P.
    Fernandez, M.F.
    Talanta, 2021, 221
  • [50] Sensitive liquid chromatography tandem mass spectrometry method for the quantification of sitagliptin, a DPP-4 inhibitor, in human plasma using liquid-liquid extraction
    Nirogi, Ramakrishna
    Kandikere, Vishwottarn
    Mudigonda, Koteshwara
    Komarneni, Prashanth
    Aleti, Raghupathi
    Boggavarapu, Rajeshkumar
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (02) : 214 - 222