Direct injection versus liquid-liquid extraction for plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry

被引:0
|
作者
Jemal, M [1 ]
Huang, M [1 ]
Jiang, XH [1 ]
Mao, Y [1 ]
Powell, ML [1 ]
机构
[1] Bristol Myers Squibb Pharmaceut Res Inst, Bioanalyt Res Metab & Pharmacokinet, New Brunswick, NJ 08903 USA
关键词
D O I
10.1002/(SICI)1097-0231(19991115)13:21<2125::AID-RCM763>3.0.CO;2-H
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Direct injection versus liquid-liquid extraction for post-dose human plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry (LC/MS/MS) have been studied using a drug candidate compound. For the direct-injection method, an Oasis(R) HLB column (1 x 50 mm, 30 mu m) was used as the on-line extraction column and a conventional Waters symmetry C18 column (3.9 x 50 mm, 5 mu m) was used as the analytical column. Each plasma sample (100 mu L) was mixed with 100 mu L of a working solution of the internal standard in aqueous 0.05 M ammonium acetate (pH 6.9), and portions (10 mu L) of these samples were then injected into the LC/MS/MS system. For the liquid-liquid extraction method, a YMC Basic C18 column (2.0 x 50 mm, 5 mu m) was used as the analytical column. Each sample (0.5 mL) was extracted with methyl tert-butyl ether and the extract was reconstituted and injected into the LC/MS/MS system. The total analysis time for both methods was 2.0 min per sample. The accuracy, inter-day precision and intra-day precision obtained from the quality control samples were within 8% for both methods. The analysis results of post-dose human plasma samples showed that the deviations of 91% of the concentrations obtained using the direct-injection method were within +/-20% from the concentrations obtained using the liquid-liquid extraction method, and the overall average percentage deviation was -1.5%. The results showed that the two methods were equivalent in terms of total chromatographic run time, accuracy and precision, However, for a batch of 100 samples, the sample preparation time for the direct-injection method was only about 25% of the time required for liquid-liquid extraction, This decrease in sample preparation time resulted in the doubling of the overall sample analysis throughput, Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:2125 / 2132
页数:8
相关论文
共 50 条
  • [31] A simple liquid-liquid extraction with hexane for low-picogram determination of drugs and their metabolites in plasma by high-performance liquid chromatography with positive ion electrospray tandem mass spectrometry
    Bioanalyt. Res., Metab. Pharmacokin., Bristol-Myers Squibb P., P.O. Box 191, New Brunswick, NJ 08903-0191, United States
    Rapid Commun. Mass Spectrom., 15 (1611-1621):
  • [32] Liquid-liquid extraction of strongly protein bound BMS-299897 from human plasma and cerebrospinal fluid, followed by high-performance liquid chromatography/tandem mass spectrometry
    Xue, Y. J.
    Pursley, Janice
    Arnold, Mark
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1728 - 1736
  • [33] Analysis of cannabinoids by liquid chromatography— Thermospray mass spectrometry and liquid chromatography— Tandem mass spectrometry
    K. Ndjoko
    J. -L. Wolfender
    K. Hostettmann
    Chromatographia, 1998, 47 : 72 - 76
  • [34] A simple liquid-liquid extraction with hexane for low-picogram determination of drugs and their metabolites in plasma by high-performance liquid chromatography with positive ion electrospray tandem mass spectrometry
    Xia, YQ
    Whigan, DB
    Jemal, M
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (15) : 1611 - 1621
  • [35] Analysis of hydrazine in drinldng water by isotope dilution gas chromatography/tandem, mass spectrometry with derivatization and liquid-liquid extraction
    Davis, William E., II
    Li, Yongtao
    ANALYTICAL CHEMISTRY, 2008, 80 (14) : 5449 - 5453
  • [36] Analysis of cannabinoids by liquid chromatography - Thermospray mass spectrometry and liquid chromatography - Tandem mass spectrometry
    Ndjoko, K
    Wolfender, JL
    Hostettmann, K
    CHROMATOGRAPHIA, 1998, 47 (1-2) : 72 - 76
  • [37] Development and Validation of a Liquid-Liquid Extraction and Gas Chromatography/Mass Spectrometry Methodology for Cannabidiol Analysis in Human Plasma
    Camargo, Stefania P. S.
    Queiroz, Regina H. C.
    Malfara, Wilson R.
    de Souza Crippa, Jose A.
    Zuardi, Antonio W.
    Hallak, Jaime E. C.
    De Martinis, Bruno S.
    CURRENT PHARMACEUTICAL ANALYSIS, 2011, 7 (04) : 228 - 234
  • [38] Determination of Eight Coccidiostats in Eggs by Liquid-Liquid Extraction-Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry
    Wang, Bo
    Liu, Jianyu
    Zhao, Xia
    Xie, Kaizhou
    Diao, Zhixiang
    Zhang, Genxi
    Zhang, Tao
    Dai, Guojun
    MOLECULES, 2020, 25 (04):
  • [39] Determination of various wine constituents using direct injection, automated off-line solid phase extraction, and liquid-liquid extraction in combination with liquid chromatography-tandem mass spectrometry
    Dumont, Emmie
    Georges, Michael
    Fulchic, Remy
    Vanhoenacker, Geed
    David, Frank
    Sandra, Pat
    AGRO FOOD INDUSTRY HI-TECH, 2010, 21 (03): : 13 - 16
  • [40] Speciation Analysis of Arsenics in Commercial Hijiki by High Performance Liquid Chromatography-tandem-mass Spectrometry and High Performance Liquid Chromatography-inductively Coupled Plasma Mass Spectrometry
    Shimoda, Yasuyo
    Suzuki, Yoshihiro
    Endo, Yoko
    Kato, Koichi
    Tachikawa, Mariko
    Endo, Ginji
    Yamanaka, Kenzo
    JOURNAL OF HEALTH SCIENCE, 2010, 56 (01) : 47 - 56