Direct liquid chromatography tandem mass spectrometry analysis of amino acids in human plasma

被引:16
|
作者
Desmons, Aurore [1 ]
Thioulouse, Elizabeth [1 ]
Hautem, Jean-Yves [1 ]
Saintier, Anne [1 ]
Baudin, Bruno [1 ]
Lamaziere, Antonin [2 ]
Netter, Claude [3 ]
Moussa, Fathi [4 ,5 ]
机构
[1] Hop A Trousseau, AP HP, Serv Biochim, F-75012 Paris, France
[2] Hop St Antoine, Lab Metabolom Clin, F-75012 Paris, France
[3] Thermo Fisher Sci, F-91000 Courtaboeuf, France
[4] Univ Paris Saclay, Inst Chim Phys, CNRS, UMR 8000, F-91400 Plateau De Moulon, France
[5] Univ Paris Saclay, IUT Orsay, F-91400 Plateau De Moulon, France
关键词
Amino acid profiling; Human plasma; LC-MS/MS; Mixed-mode stationary phases; INHERITED DISORDERS; DERIVATIZATION; DIAGNOSIS; EXCHANGE;
D O I
10.1016/j.chroma.2020.461135
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here we describe a new HPLC-MS/MS method using a mixed mode stationary phase and a binary gradient of elution for the rapid separation and quantification of AAs in human plasma without derivatization or ion pairing reagent addition. The sample preparation procedure consists in a single dilution step after protein precipitation with sulfosalicylic acid. The proposed method allows for the unambiguous identification and analysis of 52 AAs and related compounds including the separation of isomers and isobars in an 18 min chromatographic run including the conditioning and the equilibration times. AAs were detected by selective reaction monitoring. Internal calibration was used for the quantification of 37 AAs, including 25 using the corresponding isotopically labeled internal standards. External calibration (no internal standard) was used for five additional analytes. Qualitative detection was achieved for the remaining compounds. Validation studies evaluated accuracy, linearity, within- and between-run precision, lower limits of detection and quantification for 37 amino acids present in commonly used quality control samples. For within-run precision CVs averaged 3.8 % (n=30) for all compounds. For between-run precision, CVs averaged 8.6 % for all compounds (n= 20). Correlation with the common standard ion-exchange chromatography with post-column derivatization method was also performed for 32 plasma samples. While the proposed method is at least 50 times more sensitive, the data showed good correlation with slopes equal or higher than 0.9 and correlation coefficients mostly higher than 0.90. The method was successfully applied for analysis of plasma samples for detection of inherited disorders of amino acid metabolism. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Determination of underivatized amino acids in human plasma using ion pair liquid chromatography/tandem mass spectrometry
    Turner, Cheryl
    Refsum, Helga
    Bastani, Nasser E.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1229
  • [2] Analysis of Lovastatin in Human Plasma by Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Yu, X. R.
    Song, M.
    Hang, T. J.
    Wen, A. D.
    [J]. ACTA CHROMATOGRAPHICA, 2008, 20 (03) : 399 - 410
  • [3] Direct analysis of free amino acids by mixed-mode chromatography with tandem mass spectrometry
    Vilches, Ana Paola
    Norstrom, Sara H.
    Bylund, Dan
    [J]. JOURNAL OF SEPARATION SCIENCE, 2017, 40 (07) : 1482 - 1492
  • [4] Challenging the status quo: A comparison of ion exchange chromatography with liquid chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods for the measurement of amino acids in human plasma
    Carling, Rachel S.
    McDonald, Benjamin A. C.
    Austin, Donna
    Burden, Deborah
    Correia, Joana
    Leung, Jenny
    Mayers, Beverley
    John, Catharine
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2020, 57 (04) : 277 - 290
  • [5] Analysis of free amino acids in natural waters by liquid chromatography-tandem mass spectrometry
    How, Zuo Tong
    Busetti, Francesco
    Linge, Kathryn L.
    Kristiana, Ina
    Joll, Cynthia A.
    Charrois, Jeffrey W. A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1370 : 135 - 146
  • [6] Determination of amino acids in tobacco flavors by liquid chromatography tandem mass spectrometry
    Deng, Qixin
    Xie, Wei
    Huang, Chaozhang
    Su, Mingliang
    Zhang, Jianping
    Wu, Qinghui
    Huang, Huafa
    Xu, Hanchun
    Liu, Zechun
    [J]. Tobacco Science and Technology, 2014, (03): : 56 - 59
  • [7] Study of sample preparation for quantitative analysis of amino acids in human sweat by liquid chromatography-tandem mass spectrometry
    Delgado-Povedano, M. M.
    Calderon-Santiago, M.
    Priego-Capote, F.
    Luque de Castro, M. D.
    [J]. TALANTA, 2016, 146 : 310 - 317
  • [8] Determination of Amino Acids in Human Pancreas Tissue Sections Using Liquid Chromatography Tandem Mass Spectrometry
    Okamoto, Chisato
    Yoshida, Hiroo
    Nakayama, Akira
    Kikuchi, Shinya
    Ono, Nobukazu
    Miyano, Hiroshi
    Ino, Yoshinori
    Hiraoka, Nobuyoshi
    Mizukoshi, Toshimi
    [J]. CHROMATOGRAPHY, 2016, 37 (03) : 125 - 132
  • [9] Analysis of urinary aromatic acids by liquid chromatography tandem mass spectrometry
    Crow, Brian
    Bishop, Michael
    Paliakov, Ekaterina
    Norton, Dean
    George, Joe
    Bralley, J. Alexander
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (12) : 1346 - 1353
  • [10] Quantitation of bergenin in human plasma by liquid chromatography/tandem mass spectrometry
    Yu, Weisong
    Wang, Yingwu
    Zhang, Yunhui
    Lan, Jing
    Liu, Zeyuan
    Gu, Jingkai
    Fawcett, J. Paul
    Zhang, Dan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (1-2): : 33 - 36