Multichannel Raman microspectrometry of UHMWPE hip cups run on joint simulator

被引:0
|
作者
Bertoluzza, A [1 ]
Fagnano, C [1 ]
Rossi, M [1 ]
Tinti, A [1 ]
机构
[1] Univ Bologna, Dept Biochem, Ctr Studio Interfac Spettroscopia Raman, I-40126 Bologna, Italy
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
引用
收藏
页码:519 / 520
页数:2
相关论文
共 50 条
  • [31] Effect of lubricant on wear behavior of ultrahigh-molecular-weight polyethylene cups against zirconia head in hip joint simulator
    Japan Fine Ceramics Center, Nagoya, Japan
    不详
    不详
    Nano Biomed., 2009, 1 (41-50):
  • [32] A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator
    Smith, SL
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) : 475 - 483
  • [33] Fatigue test of hip-joint cups with ceramic inserts
    Soltész, U
    Richter, HG
    Schäfer, R
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2002, 33 (08) : 470 - 473
  • [34] Bio-tribological studies of Structalit/UHMWPE composites as an alternative to UHMWPE for hip joint application
    Hirwani, Jaswant Kumar
    Sinha, Sujeet K.
    WEAR, 2023, 518
  • [35] NEW JOINT SIMULATOR FOR TOTAL HIP-JOINT PROSTHESIS
    SASADA, T
    MABUCHI, K
    MAEZAWA, H
    JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1976, 21 (03): : 184 - 189
  • [36] Prediction of lubricating film thickness in UHMWPE hip joint replacements
    Jalali-Vahid, D
    Jagatia, M
    Jin, ZM
    Dowson, D
    JOURNAL OF BIOMECHANICS, 2001, 34 (02) : 261 - 266
  • [37] Prediction of lubricating film thickness in UHMWPE hip joint replacements
    Jin, ZM
    Jagatia, M
    Jalali-Vahid, D
    FRICTION, LUBRICATION, AND WEAR OF ARTIFICIAL JOINTS, 2003, : 75 - 87
  • [38] A five-station hip joint simulator
    Smith, SL
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H1) : 61 - 64
  • [39] Wear characterization of clinically used hip joint prostheses by a hip simulator
    Takigawa, Y
    Jono, K
    Takadama, H
    Mizuno, M
    Nakamura, T
    27TH INTERNATIONAL COCOA BEACH CONFERENCE ON ADVANCED CERAMICS AND COMPOSITES: A, 2003, 24 (03): : 197 - 202
  • [40] Wear rate and surface morphology of UHMWPE cups are affected by the serum lubricant concentration in a hip simulation test
    Liao, YS
    McNulty, D
    Hanes, M
    WEAR, 2003, 255 (7-12) : 1051 - 1056