A five-station hip joint simulator

被引:16
|
作者
Smith, SL [1 ]
Unsworth, A [1 ]
机构
[1] Univ Durham, Sch Engn, Ctr Biomed Engn, Sci Labs, Durham DH1 3LE, England
关键词
wear; hip simulators; zirconia ceramic; ultra-high molecular weight polyethylene; (UHMWPE);
D O I
10.1243/0954411011533535
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A five-station hip joint wear simulator was designed and built which featured simplified motion and loading. An elliptical wear path was produced using approximately sinusoidal motion in the flexion/extension and internal/external rotation axes and the dynamic loading approximated to a square wave. Five 28 mm diameter zirconia femoral heads articulated against ultra-high molecular weight polyethylene acetabular cups in 25 per cent bovine serum for 5 x 10(6) cycles. Gravimetric wear measurement was used with moisture absorption compensation using a dynamically loaded soak control. With motion of physiological magnitude, the mean acetabular cup wear rate was 52.2 mm(3)/10(6) cycles which is comparable with a number of clinical studies.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 50 条
  • [1] A 12-station anatomic hip joint simulator
    Saikko, V
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H6) : 437 - 448
  • [2] Psychometric testing and cost of a five-station OSCE for newly graduated nurses
    Goh, Hongli Sam
    Ng, Elaine
    Tang, Mun Leong
    Zhang, Hui
    Liaw, Sok Ying
    NURSE EDUCATION TODAY, 2022, 112
  • [3] A multi-station hip joint simulator study and wear characterization of commercial hip endoprostheses
    Jono, K
    Takigawa, Y
    Takadama, H
    Mizuno, M
    Nakamura, T
    27TH INTERNATIONAL COCOA BEACH CONFERENCE ON ADVANCED CERAMICS AND COMPOSITES: A, 2003, 24 (03): : 255 - 260
  • [4] Development of a ten-station, multi-axis hip joint simulator
    Goldsmith, AAJ
    Dowson, D
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H4) : 311 - 316
  • [5] Evaluation of a hip joint simulator
    Smith, SL
    Burgess, IC
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) : 469 - 473
  • [6] Discussion on the design of a hip joint simulator
    Viceconti, M
    Cavallotti, G
    Andrisano, AO
    Toni, A
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (03) : 234 - 240
  • [7] Reliability and acceptability of a five-station multiple mini-interview model for residency program recruitment
    Fraga, Julian Diaz
    Oluwasanjo, Adetokunbo
    Wasser, Thomas
    Donato, Anthony
    Alweis, Richard
    JOURNAL OF COMMUNITY HOSPITAL INTERNAL MEDICINE PERSPECTIVES, 2013, 3 (3-4):
  • [8] Ant colony optimization for power plant maintenance scheduling optimization - a five-station hydropower system
    Foong, Wai Kuan
    Simpson, Angus R.
    Maier, Holger R.
    Stolp, Stephen
    ANNALS OF OPERATIONS RESEARCH, 2008, 159 (01) : 433 - 450
  • [9] Ant colony optimization for power plant maintenance scheduling optimization—a five-station hydropower system
    Wai Kuan Foong
    Angus R. Simpson
    Holger R. Maier
    Stephen Stolp
    Annals of Operations Research, 2008, 159 : 433 - 450
  • [10] NEW JOINT SIMULATOR FOR TOTAL HIP-JOINT PROSTHESIS
    SASADA, T
    MABUCHI, K
    MAEZAWA, H
    JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1976, 21 (03): : 184 - 189