The different excitation methods of X-ray spectral analysis with proton induced X-ray emission (PIXE) and radioisotope (Cd-109) induced X-ray fluorescence (RIXRF) are evaluated and compared with regard to sensitivity, detection limit, precision, accuracy and cost, using NIST orchard leaves and pine needles standard reference materials. The accuracy and precision of both the methods for biological analysis using appropriate standards are shown to be better than 5%. The comparison of sensitivity results indicates that PIXE is comparatively more sensitive for light elements (K to Zn) and RIXRF for heavier elements (Z > 33), the crossing points being at Z = 33. Based on the present findings, PIXE is recommended for the analysis of bio-environmental samples containing low level biologically important trace elements in the range of Z = 19-30. PIXE techniques have been applied here to the analysis of 10-15 elements in some biological samples and standards with good accuracy and precision without prior pre-concentration except oven or freeze drying; a combination of PIXE and RIXRF represents a complete investigation tool for the analysis of 15-20 light and heavy elements. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:567 / 576
页数:10
相关论文
共 50 条
  • [1] COMPARISON OF DIFFERENT SAMPLE AND TARGET PREPARATION PROCEDURES FOR PIXE ANALYSIS OF BIOLOGICAL-MATERIALS
    MAENHAUT, W
    DEREU, L
    VANDENHAUTE, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 135 - 140
  • [2] SAMPLE PREPARATION IN PIXE ANALYSIS OF BIOLOGICAL-MATERIALS
    MAENHAUT, W
    DEREU, L
    VANDENHAUTE, J
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 41 : 212 - 214
  • [3] PIXE and XRF comparison for applications to sediments analysis
    Benyaich, F
    Makhtari, A
    Torrisi, L
    Foti, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 132 (03): : 481 - 488
  • [4] PIXE APPLICATIONS IN ELEMENTAL ANALYSIS OF BIOLOGICAL AND METALLURGICAL SAMPLES
    Popescu, I. V.
    Ene, A.
    Stihi, C.
    Gheboianu, A.
    Badica, T.
    JOURNAL OF SCIENCE AND ARTS, 2007, 7 : 7 - 12
  • [5] PROGRESS IN BIOLOGICAL APPLICATIONS OF PIXE
    CAMPBELL, JL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 1362 - 1367
  • [6] PROGRESS IN BIOLOGICAL APPLICATIONS OF PIXE
    CAMPBELL, JL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1036 - 1036
  • [7] Micro-PIXE analysis: importance of biological sample preparation techniques
    Budka, D
    Mesjasz-Przybylowicz, J
    Przybylowicz, WJ
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 785 - 786
  • [8] On the applications of IBA techniques to biological samples analysis:: PIXE and RBS
    Falcon-Gonzalez, J. M.
    Bernal-Alvarado, J.
    Garcia-Leon, M.
    Garcia-Tenorio, R.
    Garcia, Y. Morilla
    Sosa, M.
    MEDICAL PHYSICS, 2008, 1032 : 179 - +
  • [9] SAMPLE INHOMOGENEITY IN PIXE ANALYSIS
    KAJFOSZ, J
    SZYMCZYK, S
    KORNAS, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 147 - 150
  • [10] PIXE AT RUTGERS-UNIVERSITY - BIOLOGICAL APPLICATIONS
    HALL, GS
    ROACH, N
    NAUMANN, M
    SIMMONS, U
    CONG, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 332 - 336