PIXE and RIXRF comparison for applications to biological sample analysis

被引:12
|
作者
Ali, M [1 ]
机构
[1] Atom Energy Ctr, Div Chem, Dhaka 1000, Bangladesh
关键词
D O I
10.1016/j.nimb.2004.02.033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The different excitation methods of X-ray spectral analysis with proton induced X-ray emission (PIXE) and radioisotope (Cd-109) induced X-ray fluorescence (RIXRF) are evaluated and compared with regard to sensitivity, detection limit, precision, accuracy and cost, using NIST orchard leaves and pine needles standard reference materials. The accuracy and precision of both the methods for biological analysis using appropriate standards are shown to be better than 5%. The comparison of sensitivity results indicates that PIXE is comparatively more sensitive for light elements (K to Zn) and RIXRF for heavier elements (Z > 33), the crossing points being at Z = 33. Based on the present findings, PIXE is recommended for the analysis of bio-environmental samples containing low level biologically important trace elements in the range of Z = 19-30. PIXE techniques have been applied here to the analysis of 10-15 elements in some biological samples and standards with good accuracy and precision without prior pre-concentration except oven or freeze drying; a combination of PIXE and RIXRF represents a complete investigation tool for the analysis of 15-20 light and heavy elements. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:567 / 576
页数:10
相关论文
共 50 条
  • [41] APPLICATION OF PIXE TO TRACE-ELEMENT ANALYSIS IN BIOLOGICAL TISSUES
    HASSELMANN, I
    KOENIG, W
    RICHTER, FW
    STEINER, U
    WATJEN, U
    BODE, JC
    OHTA, W
    NUCLEAR INSTRUMENTS & METHODS, 1977, 142 (1-2): : 163 - 169
  • [42] Optimisation of Pt sensitivity in PIXE analysis of thin biological samples
    Tiourina, TB
    Mutsaers, PHA
    de Voigt, MJA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 139 (1-4): : 186 - 191
  • [43] EVALUATION OF PIXE-INDUCED XRF FOR THE ANALYSIS OF STEELS AND BIOLOGICAL SAMPLES - COMPARISON WITH TUBE-EXCITED XRF
    PEISACH, M
    MAENHAUT, W
    VANESPEN, P
    DEREU, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 253 - 258
  • [44] BIOMEDICAL APPLICATIONS OF PIXE
    LINDH, U
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 197 : 35 - NUCL
  • [45] COMPARISON OF EDXRF AND PIXE IN THE ANALYSIS OF ANCIENT GOLD COINS
    ARAUJO, MF
    ALVES, LC
    CABRAL, JMP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1993, 75 (1-4): : 450 - 453
  • [46] Effects of sample position on external beam PIXE analysis of porcelain samples
    Analytical and Testing Center, Beijing Normal University, Beijing 100875, China
    不详
    He Jishu/Nuclear Techniques, 2007, 30 (05): : 432 - 437
  • [47] APPLICATIONS OF PIXE IN DENDROCHRONOLOGY
    REVESZ, P
    MAYER, JW
    VIZKELETHY, G
    KUNIHOLM, PI
    GRIGGS, CB
    KUNIHOLM, HE
    NEWTON, MW
    TARTER, SL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 81 - NUCL
  • [48] COMPLETELY AUTOMATED PIXE ANALYSIS SYSTEM AND ITS APPLICATIONS.
    Li Ming-chien
    Sheng Kang-long
    Chin Po-kang
    Chen Zhi-xiang
    Wang Xue-peng
    Chin Jun-fa
    Rong Ting-wen
    Tan Ming-guang
    Xu Yao-liong
    Nuclear instruments and methods, 1980, 181 (1-3): : 37 - 41
  • [49] THE VALIDATION OF A PIXE SYSTEM FOR TRACE-ELEMENT ANALYSIS OF BIOLOGICAL SAMPLES
    SAIED, SO
    CRUMPTON, D
    FRANCOIS, PE
    NUCLEAR INSTRUMENTS & METHODS, 1981, 181 (1-3): : 53 - 57
  • [50] THE INFLUENCE OF TARGET PREPARATION AND MODE OF IRRADIATION ON PIXE ANALYSIS OF BIOLOGICAL SAMPLES
    GALUSZKA, J
    JARCZYK, L
    ROKITA, E
    STRZALKOWSKI, A
    SYCH, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 3 (1-3): : 141 - 146