PIXE and RIXRF comparison for applications to biological sample analysis

被引:12
|
作者
Ali, M [1 ]
机构
[1] Atom Energy Ctr, Div Chem, Dhaka 1000, Bangladesh
关键词
D O I
10.1016/j.nimb.2004.02.033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The different excitation methods of X-ray spectral analysis with proton induced X-ray emission (PIXE) and radioisotope (Cd-109) induced X-ray fluorescence (RIXRF) are evaluated and compared with regard to sensitivity, detection limit, precision, accuracy and cost, using NIST orchard leaves and pine needles standard reference materials. The accuracy and precision of both the methods for biological analysis using appropriate standards are shown to be better than 5%. The comparison of sensitivity results indicates that PIXE is comparatively more sensitive for light elements (K to Zn) and RIXRF for heavier elements (Z > 33), the crossing points being at Z = 33. Based on the present findings, PIXE is recommended for the analysis of bio-environmental samples containing low level biologically important trace elements in the range of Z = 19-30. PIXE techniques have been applied here to the analysis of 10-15 elements in some biological samples and standards with good accuracy and precision without prior pre-concentration except oven or freeze drying; a combination of PIXE and RIXRF represents a complete investigation tool for the analysis of 15-20 light and heavy elements. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:567 / 576
页数:10
相关论文
共 50 条
  • [31] Sample preparation procedure for PIXE elemental analysis on soft tissues
    B. Kubica
    W. M. Kwiatek
    E. M. Dutkiewicz
    M. Lekka
    Journal of Radioanalytical and Nuclear Chemistry, 1997, 223 : 247 - 249
  • [32] New in-air micro-PIXE system for biological applications
    Sakai, T
    Oikawa, M
    Sato, T
    Nagamine, T
    Moon, HD
    Nakazato, K
    Suzuki, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 231 : 112 - 116
  • [33] Sample preparation procedure for PIXE elemental analysis on soft tissues
    Kubica, B
    Kwiatek, WM
    Dutkiewicz, EM
    Lekka, M
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 223 (1-2) : 247 - 249
  • [34] TSPIXE. A program for quantitative PIXE analysis of thick sample
    Dai, Zhongning
    Ren, Chigang
    Liu, Nianqing
    Chinese journal of nuclear physics, 1993, 15 (02): : 133 - 135
  • [35] XRF INDUCED BY PIXE - COMPARISON WITH PIXE
    SALEH, NS
    ALSALEH, KA
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1987, 108 (06): : 363 - 373
  • [36] Comparison of fluorine determination in biological and environmental samples by NAA, PAA and PIXE
    Havránek, V
    Kucera, J
    Randa, Z
    Vosecek, V
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2004, 259 (02) : 325 - 329
  • [37] Comparison of fluorine determination in biological and environmental samples by NAA, PAA and PIXE
    V. Havránek
    J. Kučera
    Z. Řanda
    V. Voseček
    Journal of Radioanalytical and Nuclear Chemistry, 2004, 259 : 325 - 329
  • [38] A COMPLETELY AUTOMATED PIXE ANALYSIS SYSTEM AND ITS APPLICATIONS
    LI, MC
    SHENG, KL
    CHIN, PK
    CHEN, ZX
    WANG, XP
    CHIN, JF
    RONG, TW
    TAN, MG
    XU, YL
    NUCLEAR INSTRUMENTS & METHODS, 1981, 181 (1-3): : 37 - 41
  • [39] QUANTITATIVE-ANALYSIS OF PIXE SPECTRA IN GEOSCIENCE APPLICATIONS
    RYAN, CG
    COUSENS, DR
    SIE, SH
    GRIFFIN, WL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 49 (1-4): : 271 - 276
  • [40] Continuous flow electrophoretic separation - Recent developments and applications to biological sample analysis
    Stastna, Miroslava
    ELECTROPHORESIS, 2020, 41 (1-2) : 36 - 55