Modeling temperature effects on a Coriolis mass flowmeter

被引:6
|
作者
Costa, Fabio Ouverney [1 ]
Pope, Jodie G. [2 ]
Gillis, Keith A. [2 ]
机构
[1] Inst Nacl Metrol, Directory Sci & Ind Metrol, Fluid Dynam Metrol Div, Duque De Caxias, RJ, Brazil
[2] NIST, Fluid Metrol Grp, Gaithersburg, MD 20899 USA
关键词
Coriolis meter; Temperature-effects; Physical model; Flowmeter; Cryogenic; ELASTIC-CONSTANTS;
D O I
10.1016/j.flowmeasinst.2020.101811
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Coriolis mass flowmeters are used for many applications, including as transfer standards for proficiency testing and liquified natural gas (LNG) custody transfer. We developed a model to explain the temperature dependence of a Coriolis meter down to cryogenic temperatures. As a first step, we tested our model over the narrow temperature range of 285 K to 318 K in this work. The temperature dependence predicted by the model agrees with experimental data within +/- 0.08 %; the model uncertainty is 0.16 % (95 % confidence level) over the temperature range of this work. Here, basic concepts of Coriolis flowmeters will be presented, and correction coefficients will be proposed that are valid down to 5 K based on literature values of material properties.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Research for theoretical model of straight tube Coriolis mass flowmeter
    Zhou, Yongquan
    Zheng, Ronggen
    Zhao, Xueduan
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 1995, 16 (03): : 243 - 248
  • [32] Coriolis flowmeter calibration
    Buttler, Marc
    InTech, 2020, 67 (5-6):
  • [33] DSP-based signal processing system of Coriolis mass flowmeter
    Xu, Kejun
    Yu, Cuixin
    Su, Jianhui
    Chen, Rongbao
    Liu, Jiajun
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2002, 23 (02):
  • [34] Calculation of the sensitivity of a straight tube Coriolis mass flowmeter with free ends
    Hemp, J
    FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 12 (5-6) : 411 - 420
  • [35] A novel time varying signal processing method for Coriolis mass flowmeter
    Shen, Ting-Ao
    Tu, Ya-Qing
    Zhang, Hai-Tao
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (06):
  • [36] Analysis of Phase Difference Tracking Methods for Signal of Coriolis Mass Flowmeter
    Yi, Peng
    Tu, Yaqing
    Xie, Min
    Shen, Ting'ao
    PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 4368 - 4373
  • [37] Measuring tube structure optimization of coriolis mass flowmeter with liquid hydrogen
    Pei, Xiangxiang
    Yu, Lianyan
    Li, Xiang
    Xu, Haohao
    Zhang, Xiaobin
    FLOW MEASUREMENT AND INSTRUMENTATION, 2024, 97
  • [38] Development of Coriolis mass flowmeter with digital drive and signal processing technology
    Hou, Qi-Li
    Xu, Ke-Jun
    Fang, Min
    Liu, Cui
    Xiong, Wen-Jun
    ISA TRANSACTIONS, 2013, 52 (05) : 692 - 700
  • [39] Application of novel method of digital to frequency conversion in Coriolis mass flowmeter
    Zheng, Dezhi
    Fan, Shangchun
    Xing, Weiwei
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2006, 32 (01): : 50 - 52
  • [40] Coriolis mass flowmeter works under two-phase flow
    不详
    HYDROCARBON PROCESSING, 2003, 82 (01): : 25 - +