Modeling temperature effects on a Coriolis mass flowmeter

被引:6
|
作者
Costa, Fabio Ouverney [1 ]
Pope, Jodie G. [2 ]
Gillis, Keith A. [2 ]
机构
[1] Inst Nacl Metrol, Directory Sci & Ind Metrol, Fluid Dynam Metrol Div, Duque De Caxias, RJ, Brazil
[2] NIST, Fluid Metrol Grp, Gaithersburg, MD 20899 USA
关键词
Coriolis meter; Temperature-effects; Physical model; Flowmeter; Cryogenic; ELASTIC-CONSTANTS;
D O I
10.1016/j.flowmeasinst.2020.101811
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Coriolis mass flowmeters are used for many applications, including as transfer standards for proficiency testing and liquified natural gas (LNG) custody transfer. We developed a model to explain the temperature dependence of a Coriolis meter down to cryogenic temperatures. As a first step, we tested our model over the narrow temperature range of 285 K to 318 K in this work. The temperature dependence predicted by the model agrees with experimental data within +/- 0.08 %; the model uncertainty is 0.16 % (95 % confidence level) over the temperature range of this work. Here, basic concepts of Coriolis flowmeters will be presented, and correction coefficients will be proposed that are valid down to 5 K based on literature values of material properties.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Coriolis mass flowmeter with a single straight tube and electronical correction of vibrations
    Rieder, A
    TECHNISCHES MESSEN, 1999, 66 (04): : 156 - 162
  • [42] On the performance of a Coriolis Mass Flowmeter (CMF): Experimental measurement and FSI simulation
    Gace D.A.
    International Journal of Metrology and Quality Engineering, 2022, 13
  • [43] The monolithic coupling of straight tube Coriolis mass flowmeter with liquid hydrogen
    Pei, Xiangxiang
    Chen, Qiangfeng
    Sun, Shien
    Song, Yucai
    Qiu, Limin
    Zhang, Xiaobin
    CRYOGENICS, 2023, 129
  • [44] Structural Influence on the Performance Based on Uncertainty Analysis for Coriolis Mass Flowmeter
    Feng, D.
    Fan, S.
    Zheng, D.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2018, 33 (01): : 15 - 27
  • [45] Structural Influence on the Performance Based on Uncertainty Analysis for Coriolis Mass Flowmeter
    Dan Feng
    Shangchun Fan
    Dezhi Zheng
    MAPAN, 2018, 33 : 15 - 27
  • [46] Effects of boundary conditions on phase shift of a dual-tube conveying fluid in the Coriolis mass flowmeter
    Javan, M. Vesaghati
    Navazi, H. M.
    JOURNAL OF FLUIDS AND STRUCTURES, 2023, 118
  • [47] Coriolis flowmeter demand grows
    Sharke, P
    MECHANICAL ENGINEERING, 2004, 126 (04) : 20 - 21
  • [48] Metrological properties of Coriolis flowmeter
    Wedrychowicz, Wieslaw
    Andruszkiewicz, Artur
    Synowiec, Piotr
    Piechota, Piotr
    PRZEGLAD ELEKTROTECHNICZNY, 2018, 94 (09): : 68 - 70
  • [49] Ap-Hilbert method for phase difference estimation of Coriolis mass flowmeter
    Yang H.
    Tu Y.
    Mao Y.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (01): : 35 - 42
  • [50] Research and application of the zero-point model of the sensor in Coriolis mass flowmeter
    Luo F.
    Gan R.
    Zhao P.
    Chen Q.
    Xiong M.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (08): : 15 - 23