Development of Coriolis mass flowmeter with digital drive and signal processing technology

被引:36
|
作者
Hou, Qi-Li [1 ]
Xu, Ke-Jun [1 ,2 ]
Fang, Min [1 ]
Liu, Cui [1 ]
Xiong, Wen-Jun [1 ]
机构
[1] Hefei Univ Technol, Sch Elect & Automat Engn, Hefei 230009, Peoples R China
[2] Engn Technol Res Ctr Ind Automat, Hefei 230009, Peoples R China
关键词
Coriolis mass flowmeter; Digital signal processing; Flow measurement; Industrial measurement; Digital drive method; Transmitter development;
D O I
10.1016/j.isatra.2013.05.001
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Coriolis mass flowmeter (CMF) often suffers from two-phase flowrate which may cause flowtube stalling. To solve this problem, a digital drive method and a digital signal processing method of CMF is studied and implemented in this paper. A positive-negative step signal is used to initiate the flowtube oscillation without knowing the natural frequency of the flowtube. A digital zero-crossing detection method based on Lagrange interpolation is adopted to calculate the frequency and phase difference of the sensor output signals in order to synthesize the digital drive signal. The digital drive approach is implemented by a multiplying digital to analog converter (MDAC) and a direct digital synthesizer (DDS). A digital Coriolis mass flow transmitter is developed with a digital signal processor (DSP) to control the digital drive, and realize the signal processing. Water flow calibrations and gas-liquid two-phase flowrate experiments are conducted to examine the performance of the transmitter. The experimental results show that the transmitter shortens the start-up time and can maintain the oscillation of flowtube in two-phase flowrate condition. (C) 2013 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:692 / 700
页数:9
相关论文
共 50 条
  • [1] Digital signal processing method of Coriolis mass flowmeter
    Zhang Haitao
    Tu Yaqing
    Niu Penghui
    [J]. Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 466 - 470
  • [2] A new signal processing method for Coriolis mass flowmeter
    Xu, K.
    Ni, W.
    [J]. Jiliang Xuebao/Acta Metrologica Sinica, 2001, 22 (04): : 254 - 258
  • [3] A novel time varying signal processing method for Coriolis mass flowmeter
    Shen, Ting-Ao
    Tu, Ya-Qing
    Zhang, Hai-Tao
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (06):
  • [4] DSP-based signal processing system of Coriolis mass flowmeter
    Xu, Kejun
    Yu, Cuixin
    Su, Jianhui
    Chen, Rongbao
    Liu, Jiajun
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2002, 23 (02):
  • [5] A Novel Method Based on Hilbert Transform for Signal Processing of Coriolis Mass Flowmeter
    Lin, Wei
    Zhao, Jing-Lei
    [J]. INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2018, 32 (02)
  • [6] Coriolis mass flowmeter signal processing system based on time-varying signal model
    Chen, Nan
    Xiao, Ying
    Liu, Zhijun
    [J]. JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2023, 23 (02) : 837 - 853
  • [7] Study and implementation of processing method for time-varying signal of Coriolis mass flowmeter
    Li, Ye
    Xu, Kejun
    Zhu, Zhihai
    Zhu, Yongqiang
    Hou, Qili
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (01): : 8 - 14
  • [8] A Novel Signal Processing Method for Coriolis Mass Flowmeter Based on Time-varying Signal Model
    Zhang, Haitao
    Tu, Yaqing
    Liu, Liangbing
    Niu, Penghui
    [J]. 2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 6887 - +
  • [9] Digital closed loop system of Coriolis mass flowmeter
    Xing, Weiwei
    Fan, Shangchun
    Zheng, Dezhi
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2006, 27 (05): : 461 - 465
  • [10] Development of Small Size Coriolis Mass Flowmeter
    Ki-Won, Lim
    Jueng-Keun, Ji
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (06) : 497 - 504