Development of Coriolis mass flowmeter with digital drive and signal processing technology

被引:36
|
作者
Hou, Qi-Li [1 ]
Xu, Ke-Jun [1 ,2 ]
Fang, Min [1 ]
Liu, Cui [1 ]
Xiong, Wen-Jun [1 ]
机构
[1] Hefei Univ Technol, Sch Elect & Automat Engn, Hefei 230009, Peoples R China
[2] Engn Technol Res Ctr Ind Automat, Hefei 230009, Peoples R China
关键词
Coriolis mass flowmeter; Digital signal processing; Flow measurement; Industrial measurement; Digital drive method; Transmitter development;
D O I
10.1016/j.isatra.2013.05.001
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Coriolis mass flowmeter (CMF) often suffers from two-phase flowrate which may cause flowtube stalling. To solve this problem, a digital drive method and a digital signal processing method of CMF is studied and implemented in this paper. A positive-negative step signal is used to initiate the flowtube oscillation without knowing the natural frequency of the flowtube. A digital zero-crossing detection method based on Lagrange interpolation is adopted to calculate the frequency and phase difference of the sensor output signals in order to synthesize the digital drive signal. The digital drive approach is implemented by a multiplying digital to analog converter (MDAC) and a direct digital synthesizer (DDS). A digital Coriolis mass flow transmitter is developed with a digital signal processor (DSP) to control the digital drive, and realize the signal processing. Water flow calibrations and gas-liquid two-phase flowrate experiments are conducted to examine the performance of the transmitter. The experimental results show that the transmitter shortens the start-up time and can maintain the oscillation of flowtube in two-phase flowrate condition. (C) 2013 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:692 / 700
页数:9
相关论文
共 50 条
  • [21] Analysis of Phase Difference Tracking Methods for Signal of Coriolis Mass Flowmeter
    Yi, Peng
    Tu, Yaqing
    Xie, Min
    Shen, Ting'ao
    PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 4368 - 4373
  • [22] Application of novel method of digital to frequency conversion in Coriolis mass flowmeter
    Zheng, Dezhi
    Fan, Shangchun
    Xing, Weiwei
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2006, 32 (01): : 50 - 52
  • [23] Developing a Long Short-Term Memory-based signal processing method for Coriolis mass flowmeter
    Zhang, Yanjin
    Liu, Yajun
    Liu, Zhendong
    Liang, Weiping
    MEASUREMENT, 2019, 148
  • [24] Research on signal processing of coriolis mass flowmeters
    Xu, KJ
    Yu, CX
    Jiang, HK
    Su, JH
    Chen, RB
    Liu, JJ
    ICEMI'99: FOURTH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 1999, : 835 - 841
  • [25] Startup method of digital Coriolis mass flowmeter using alternating exciting of positive-negative step signal
    Li, Miao
    Xu, Kejun
    Hou, Qili
    Zhu, Yongqiang
    Li, Ye
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (01): : 172 - 177
  • [26] Analysis of Signal Processing Algorithms of Coriolis Mass Flowmeters
    Ruoff, Juergen
    Gauchel, Wolfgang
    Kuech, Heinz
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS III, 2014, 605 : 408 - 411
  • [27] Implementation of measuring signal sampling and teal-time algorithm in coriolis mass flowmeter
    Shi, Fuyuan
    Huazhong Ligong Daxue Xuebao/Journal Huazhong (Central China) University of Science and Technology, 1998, 26 (07): : 77 - 79
  • [28] Direct viscosity measurement with a Coriolis mass flowmeter
    Fuchs, M
    Drahm, W
    Bjönnes, H
    Sprich, HJ
    SENSORS AND MEASURING SYSTEMS 2004, 2004, 1829 : 273 - 279
  • [29] CORIOLIS MASS FLOWMETER IS READY FOR THE TOUGH JOBS
    CHIN, W
    I&CS-INSTRUMENTATION & CONTROL SYSTEMS, 1992, 65 (02): : 25 - 27
  • [30] A Novel Drive Scheme of Coriolis Mass Flowmeter Based on Adaptive Fuzzy Sliding Mode Control
    Ren, Jianxin
    Zhang, Rui
    Zang, Tian
    Yang, Xinghui
    Tang, Xiaodong
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION ENGINEERING (ECAE 2017), 2017, 140 : 133 - 137