Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review

被引:45
|
作者
Jabran, Ali [1 ]
Peach, Chris [1 ,2 ]
Ren, Lei [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester, Lancs, England
[2] Univ Hosp South Manchester, Dept Shoulder & Elbow Surg, Manchester, Lancs, England
来源
基金
英国工程与自然科学研究理事会;
关键词
Proximal humerus fractures; Locking plates; Open reduction internal fixation; Biomechanical testing; SURGICAL NECK FRACTURES; INTRAMEDULLARY FIBULAR ALLOGRAFT; CALCIUM-PHOSPHATE CEMENT; HUMAN SHOULDER SPECIMENS; MEDIAL CORTICAL SUPPORT; FINITE-ELEMENT-ANALYSIS; ANGULAR STABLE PLATE; ROTATOR CUFF SUTURES; IN-VITRO ASSESSMENT; LOCKING PLATE;
D O I
10.1186/s12938-018-0479-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use. A comprehensive review of in vitro biomechanical studies is needed for the comparison of plates' mechanical performance and the testing methodologies. This will not only guide clinicians with plate selection but also with the design of future in vitro biomechanical studies. This review was aimed to systematically categorise and review the in vitro biomechanical studies of these plates based on their protocols and discuss their results. The technologies and techniques investigated in these studies were categorised and compared to reach a census where possible. Methods and results: Web of Science and Scopus database search yielded 62 studies. Out of these, 51 performed axial loading, torsion, bending and/or combined bending and axial loading while 11 simulated complex glenohumeral movements by using tendons. Loading conditions and set-up, failure criteria and performance parameters, as well as results for each study, were reviewed. Only two studies tested four-part fracture model while the rest investigated two-and three-part fractures. In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load-displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. Conclusions: Overall, PHILOS was the most tested plate and locking plates demonstrated better mechanical performance than non-locking ones. Conflicting results have been published for their comparison with non-locking blade plates and polyaxial locking screws. Augmentation with cement [calcium phosphate or poly(methyl methacrylate)] or allografts (fibular and femoral head) was found to improve bone-plate constructs' mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.
引用
收藏
页数:30
相关论文
共 50 条
  • [41] Dual plate fixation of proximal humerus fractures: Retrospective review and surgical technique
    Alqahtani, Saad M.
    Aljamaan, Yousef
    Abusultan, Ammar
    Alzahrani, Mohammad M.
    SHOULDER & ELBOW, 2023, 15 (06) : 641 - 646
  • [42] Proximal Humerus Fractures In The Older Adult: A Retrospective Review Of Proximal Humerus Fractures In The Emergency Department
    Connolly, Kieron
    Green, Natasha Li
    Mohamed, Behnazir
    Coughlan, Tara
    McCabe, Aileen
    AGE AND AGEING, 2024, 53
  • [43] Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model
    Walsh, Stephen
    Reindl, Rudy
    Harvey, Edward
    Berry, Gregory
    Beckman, Lorne
    Steffen, Thomas
    CLINICAL BIOMECHANICS, 2006, 21 (10) : 1027 - 1031
  • [44] Fibular Autograft as Medial Support with Proximal Humerus Locking Plate Construct in Comminuted Proximal Humerus Fractures: A Retrospective Analysis
    Sameer Panchal
    Sangeet Gawhale
    Amit Kumar Yadav
    Devanshu Gupta
    K. S. Akshay
    Indian Journal of Orthopaedics, 2023, 57 : 1443 - 1451
  • [45] Fibular Autograft as Medial Support with Proximal Humerus Locking Plate Construct in Comminuted Proximal Humerus Fractures: A Retrospective Analysis
    Panchal, Sameer
    Gawhale, Sangeet
    Yadav, Amit Kumar
    Gupta, Devanshu
    Akshay, K. S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (09) : 1443 - 1451
  • [46] Biomechanical comparison of screw-based zones of a spatial subchondral support plate for proximal humerus fractures
    Jabran, Ali
    Peach, Chris
    Zou, Zhenmin
    Ren, Lei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (03) : 372 - 382
  • [48] A new locking plate for unstable fractures of the proximal humerus
    Fankhauser, F
    Boldin, C
    Schippinger, G
    Haunschmid, C
    Szyszkowitz, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 176 - 181
  • [49] Complications Associated with Locking Plate of Proximal Humerus Fractures
    Venkat Kavuri
    Blake Bowden
    Neil Kumar
    Doug Cerynik
    Indian Journal of Orthopaedics, 2018, 52 : 108 - 116
  • [50] Fixation of proximal humerus fractures using the PHILOS plate
    Koukakis, Athanasios
    Apostolou, Constantinos D.
    Taneja, Tarun
    Korres, Dimitrios S.
    Amini, Alexander
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (442) : 115 - 120