Complications Associated with Locking Plate of Proximal Humerus Fractures

被引:0
|
作者
Venkat Kavuri
Blake Bowden
Neil Kumar
Doug Cerynik
机构
[1] Drexel University College of Medicine,Department of Orthopaedic Surgery
[2] Hahnemann University Hospital,undefined
来源
关键词
Fracture; proximal humerus; locking plate; complications; Bone plates; humeral fractures; proximal; surgical complications;
D O I
暂无
中图分类号
学科分类号
摘要
Proximal humerus fractures constitute a significant percentage of fragility fractures. The growing use of locking plate has helped treat this problem, but at the same time has brought about complications. Past systematic reviews have documented these complications, however a large number of recent studies have been published since, reporting their own complication rates with different techniques. This study reviews the current complications associated with locking plate of proximal humerus fractures as well as methods to reduce them. A systematic review, following the PRISMA guidelines, was conducted in November 2013 and repeated in March 2015, using PubMed, Scopus, and Cochrane databases, to evaluate locking plate fixation (and complications) of traumatic proximal humerus fractures. Inclusion criteria included adults (>18 years), minimum of 12-month postoperative followup, articles within the last 5 years, and studies with >10 participants. Exclusion criteria included pathologic fractures, cadaveric studies, and nonhuman subjects. Eligible studies were graded using a quality scoring system. Articles with a minimum of 7/10 score were included and assessed regarding their level of evidence per the Journal of Bone and Joint Surgery and Centre for Evidence-Based Medicine guidelines. The initial query identified 51,206 articles from multiple databases. These records were thoroughly screened and resulted in 57 articles, consisting of seven Level 1, three Level 2, 10 Level 3, and 37 Level 4 studies, totaling 3422 proximal humerus fractures treated with locking plates. Intraarticular screw penetration was the most reported complication (9.5%), followed by varus collapse (6.8%), subacromial impingement (5.0%), avascular necrosis (4.6%), adhesive capsulitis (4.0%), nonunion (1.5%), and deep infection (1.4%). Reoperation occurred at a rate of 13.8%. Collapse at the fracture site contributed to a majority of the implant-related complications, which in turn were the main reasons for reoperation. The authors of these studies discussed different techniques that could be used to address these issues. Expanding use of locking plate in the proximal humerus fractures leads to improvements and advancements in surgical technique. Further research is necessary to outline indications to decrease complications, further.
引用
收藏
页码:108 / 116
页数:8
相关论文
共 50 条
  • [1] Complications Associated with Locking Plate of Proximal Humerus Fractures
    Kavuri, Venkat
    Bowden, Blake
    Kumar, Neil
    Cerynik, Doug
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (02) : 108 - 116
  • [2] Complications after Locking Plate Fixation of Fractures of the Proximal Humerus
    Gerber, Christian
    Spross, Christian
    Gren, Holger
    Jost, Bernhard
    SWISS MEDICAL WEEKLY, 2011, 141 : 29S - 29S
  • [3] Functional Outcome and Complications in Management of Proximal Humerus Fractures Operated with Proximal Humerus Locking Plate
    George, P. K.
    Dasgupta, B.
    Bhaladhare, S. M.
    Reddy, B. P., V
    Jain, A.
    Jogani, A. D.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (02) : 47 - 54
  • [4] Complications encountered in proximal humerus fractures treated with locking plate fixation
    Aksu, Neslihan
    Gogus, Abdullah
    Kara, Ayhan Nedim
    Isiklar, Zekeriya Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2010, 44 (02) : 89 - 96
  • [5] Locking Plate Fixation of Proximal Humerus Fractures
    Strohm, Peter C.
    Koestler, Wolfgang
    Suedkamp, Norbert P.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2005, 6 (01): : 8 - 13
  • [6] Locking Plate Fixation for Proximal Humerus Fractures
    Burke, Neil G.
    Kennedy, Jim
    Green, Connor
    Dodds, Michael K.
    Mullett, Hannan
    ORTHOPEDICS, 2012, 35 (02) : E250 - E254
  • [7] Locking plate osteosynthesis for fractures of the proximal humerus
    Lungershausen, W
    Bach, O
    Lorenz, CO
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (01): : 28 - 33
  • [8] Factors associated with failure of locking plate fixation in proximal humerus fractures
    Cosic, Filip
    Kirzner, Nathan
    Edwards, Elton
    Page, Richard
    Kimmel, Lara
    Gabbe, Belinda
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2025, 56 (02):
  • [9] To Detect the Outcome of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Ahmed, Nasir
    Khan, Tarique Ali
    Anwar, Muhammad Absar
    Ali, Ahmed
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (01): : 281 - 285
  • [10] A new locking plate for unstable fractures of the proximal humerus
    Fankhauser, F
    Boldin, C
    Schippinger, G
    Haunschmid, C
    Szyszkowitz, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 176 - 181