Complications Associated with Locking Plate of Proximal Humerus Fractures

被引:0
|
作者
Venkat Kavuri
Blake Bowden
Neil Kumar
Doug Cerynik
机构
[1] Drexel University College of Medicine,Department of Orthopaedic Surgery
[2] Hahnemann University Hospital,undefined
来源
关键词
Fracture; proximal humerus; locking plate; complications; Bone plates; humeral fractures; proximal; surgical complications;
D O I
暂无
中图分类号
学科分类号
摘要
Proximal humerus fractures constitute a significant percentage of fragility fractures. The growing use of locking plate has helped treat this problem, but at the same time has brought about complications. Past systematic reviews have documented these complications, however a large number of recent studies have been published since, reporting their own complication rates with different techniques. This study reviews the current complications associated with locking plate of proximal humerus fractures as well as methods to reduce them. A systematic review, following the PRISMA guidelines, was conducted in November 2013 and repeated in March 2015, using PubMed, Scopus, and Cochrane databases, to evaluate locking plate fixation (and complications) of traumatic proximal humerus fractures. Inclusion criteria included adults (>18 years), minimum of 12-month postoperative followup, articles within the last 5 years, and studies with >10 participants. Exclusion criteria included pathologic fractures, cadaveric studies, and nonhuman subjects. Eligible studies were graded using a quality scoring system. Articles with a minimum of 7/10 score were included and assessed regarding their level of evidence per the Journal of Bone and Joint Surgery and Centre for Evidence-Based Medicine guidelines. The initial query identified 51,206 articles from multiple databases. These records were thoroughly screened and resulted in 57 articles, consisting of seven Level 1, three Level 2, 10 Level 3, and 37 Level 4 studies, totaling 3422 proximal humerus fractures treated with locking plates. Intraarticular screw penetration was the most reported complication (9.5%), followed by varus collapse (6.8%), subacromial impingement (5.0%), avascular necrosis (4.6%), adhesive capsulitis (4.0%), nonunion (1.5%), and deep infection (1.4%). Reoperation occurred at a rate of 13.8%. Collapse at the fracture site contributed to a majority of the implant-related complications, which in turn were the main reasons for reoperation. The authors of these studies discussed different techniques that could be used to address these issues. Expanding use of locking plate in the proximal humerus fractures leads to improvements and advancements in surgical technique. Further research is necessary to outline indications to decrease complications, further.
引用
收藏
页码:108 / 116
页数:8
相关论文
共 50 条
  • [41] Fibular Autograft as Medial Support with Proximal Humerus Locking Plate Construct in Comminuted Proximal Humerus Fractures: A Retrospective Analysis
    Sameer Panchal
    Sangeet Gawhale
    Amit Kumar Yadav
    Devanshu Gupta
    K. S. Akshay
    Indian Journal of Orthopaedics, 2023, 57 : 1443 - 1451
  • [42] Fibular Autograft as Medial Support with Proximal Humerus Locking Plate Construct in Comminuted Proximal Humerus Fractures: A Retrospective Analysis
    Panchal, Sameer
    Gawhale, Sangeet
    Yadav, Amit Kumar
    Gupta, Devanshu
    Akshay, K. S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (09) : 1443 - 1451
  • [43] Management of complications after angularly stable locking proximal humerus plate fixation
    Voigt, C.
    Woltmann, A.
    Partenheimer, A.
    Lill, H.
    CHIRURG, 2007, 78 (01): : 40 - 46
  • [44] Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?
    Koenigshausen, M.
    Kuebler, L.
    Godry, H.
    Citak, M.
    Schildhauer, T. A.
    Seybold, D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 223 - 231
  • [45] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Jabran, Ali
    Peach, Chris
    Zou, Zhenmin
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [46] Computational optimisation of screw orientations for improved locking plate fixation of proximal humerus fractures
    Mischler, Dominic
    Windolf, Markus
    Gueorguiev, Boyko
    Nijs, Stefaan
    Varga, Peter
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 25 : 96 - 104
  • [47] Osteoporosis is a risk factor for locking-plate implant failure of proximal humerus fractures
    Haasters, F.
    Kindsvater, J.
    Siebenbuerger, G.
    Mutschler, W.
    Ockert, B.
    OSTEOLOGIE, 2014, 23 (01) : 16 - 21
  • [48] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Ali Jabran
    Chris Peach
    Zhenmin Zou
    Lei Ren
    BioMedical Engineering OnLine, 17
  • [49] Clinical efficacy of locking plate combined with suture anchors for the treatment of proximal humerus fractures
    Li, Yiping
    Wu, Zonghong
    Yang, Jinsong
    Zheng, Jinwen
    Xiang, Ming
    MINERVA SURGERY, 2024,
  • [50] Anterolateral acromial approach in locking plate fixation of proximal humerus fractures in elderly patients
    Cai, Jun-Feng
    Yuan, Feng
    Ma, Min
    Zhou, Wei
    Luo, Shu-Lin
    Yin, Feng
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (05): : 502 - 508