Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review

被引:45
|
作者
Jabran, Ali [1 ]
Peach, Chris [1 ,2 ]
Ren, Lei [1 ]
机构
[1] Univ Manchester, Sch Mech Aerosp & Civil Engn, Manchester, Lancs, England
[2] Univ Hosp South Manchester, Dept Shoulder & Elbow Surg, Manchester, Lancs, England
来源
基金
英国工程与自然科学研究理事会;
关键词
Proximal humerus fractures; Locking plates; Open reduction internal fixation; Biomechanical testing; SURGICAL NECK FRACTURES; INTRAMEDULLARY FIBULAR ALLOGRAFT; CALCIUM-PHOSPHATE CEMENT; HUMAN SHOULDER SPECIMENS; MEDIAL CORTICAL SUPPORT; FINITE-ELEMENT-ANALYSIS; ANGULAR STABLE PLATE; ROTATOR CUFF SUTURES; IN-VITRO ASSESSMENT; LOCKING PLATE;
D O I
10.1186/s12938-018-0479-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use. A comprehensive review of in vitro biomechanical studies is needed for the comparison of plates' mechanical performance and the testing methodologies. This will not only guide clinicians with plate selection but also with the design of future in vitro biomechanical studies. This review was aimed to systematically categorise and review the in vitro biomechanical studies of these plates based on their protocols and discuss their results. The technologies and techniques investigated in these studies were categorised and compared to reach a census where possible. Methods and results: Web of Science and Scopus database search yielded 62 studies. Out of these, 51 performed axial loading, torsion, bending and/or combined bending and axial loading while 11 simulated complex glenohumeral movements by using tendons. Loading conditions and set-up, failure criteria and performance parameters, as well as results for each study, were reviewed. Only two studies tested four-part fracture model while the rest investigated two-and three-part fractures. In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load-displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. Conclusions: Overall, PHILOS was the most tested plate and locking plates demonstrated better mechanical performance than non-locking ones. Conflicting results have been published for their comparison with non-locking blade plates and polyaxial locking screws. Augmentation with cement [calcium phosphate or poly(methyl methacrylate)] or allografts (fibular and femoral head) was found to improve bone-plate constructs' mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.
引用
收藏
页数:30
相关论文
共 50 条
  • [31] A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Yang, Huiguang
    Li, Zhongze
    Zhou, Feng
    Wang, Daoyuan
    Zhong, Baoliang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (01) : 11 - 17
  • [32] A Prospective Clinical Study of Proximal Humerus Fractures Treated With a Locking Proximal Humerus Plate
    Bali, Kamal
    Krishnan, Vibhu
    Aggarwal, Sameer
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (04) : E42 - E42
  • [33] Reverse shoulder arthroplasty in acute fractures of the proximal humerus: A systematic review
    Brorson, Stig
    Rasmussen, Jeppe V.
    Olsen, Bo S.
    Frich, Lars H.
    Jensen, Steen L.
    Hrobjartsson, Asbjorn
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2013, 7 (02): : 70 - 78
  • [34] Treatment of proximal humerus fractures in the elderly A systematic review of 409 patients
    Launonen, Antti P.
    Lepola, Vesa
    Flinkkila, Tapio
    Laitinen, Minna
    Paavola, Mika
    Malmivaara, Antti
    ACTA ORTHOPAEDICA, 2015, 86 (03) : 280 - 285
  • [35] Reverse shoulder arthroplasty for acute proximal humerus fractures: a systematic review
    Anakwenze, Oke A.
    Zoller, Stephen
    Ahmad, Christopher S.
    Levine, William N.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (04) : E73 - E80
  • [36] Predictors of outcomes of proximal humerus fractures in children and adolescents: A systematic review
    Abbot, Samuel
    Proudman, Susanna
    Ravichandran, Bhuvanesh
    Williams, Nicole
    JOURNAL OF CHILDRENS ORTHOPAEDICS, 2022, 16 (05) : 347 - 354
  • [37] A biomechanical comparison of plate configuration in distal humerus fractures
    Arnander, Magnus W. T.
    Reeves, Alexander
    MacLeod, Iain A. R.
    Pinto, Thomas M.
    Khaleel, Arshad
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) : 332 - 336
  • [38] Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review
    Brorson, Stig
    Rasmussen, Jeppe Vejlgaard
    Frich, Lars Henrik
    Olsen, Bo Sanderhoff
    Hrobjartsson, Asbjorn
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07): : 999 - 1005
  • [39] Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus A systematic review of benefits and harms
    Brorson, Stig
    Frich, Lars H.
    Winther, Annika
    Hrobjartsson, Asbjorn
    ACTA ORTHOPAEDICA, 2011, 82 (04) : 475 - 481
  • [40] Outcomes of intramedullary nailing for acute proximal humerus fractures: a systematic review
    Wong J.
    Newman J.M.
    Gruson K.I.
    Journal of Orthopaedics and Traumatology, 2016, 17 (2) : 113 - 122