Multidetector Row Computed Tomography Parameters Associated With Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation

被引:18
|
作者
Katsanos, Spyridon [1 ]
Ewe, See Hooi [1 ]
Debonnaire, Philippe [1 ]
van der Kley, Frank [1 ]
de Weger, Arend [2 ]
Palmen, Meindert [2 ]
Scholte, Arthur J. H. A. [1 ]
Schalij, Martin J. [1 ]
Bax, Jeroen J. [1 ]
Marsan, Nina Ajmone [1 ]
Delgado, Victoria [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Cardiothorac Surg, Leiden, Netherlands
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2013年 / 112卷 / 11期
关键词
EAE/ASE RECOMMENDATIONS; EUROPEAN-ASSOCIATION; REPLACEMENT; STENOSIS; OUTCOMES; IMPACT; ECHOCARDIOGRAPHY; INTERVENTIONS; METAANALYSIS; PREDICTORS;
D O I
10.1016/j.amjcard.2013.07.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multidetector row computed tomographic (MDCT) assessment of aortic annulus dimensions and frame position and deployment have been associated with paravalvular aortic regurgitation (PAVR) after transcatheter aortic valve implantation (TAVI). The present evaluation investigated the (pre- and postprocedure) MDCT associates of PAVR >= 2+. In total, 123 patients referred for TAVI underwent clinical evaluation, transthoracic echocardiography, and pre- and post-TAVI MDCT. Pre-TAVI MDCT measurements of the aortic annular dimensions and post-TAVI MDCT evaluation of the position and deployment of the prosthesis in the native annulus were performed. At 1-month follow-up, PAVR +/- 2+ was observed in 25 patients (20%). The difference between the MDCT-derived maximum aortic annulus and the nominal diameters of the implanted prosthesis (odds ratio 1.912, p = 0.002) and shallow position of the frame in the left ventricular outflow tract (<2 mm) (odds ratio 4.865, p = 0.017) were independently related to significant PAVR. A maximum annulus diameter >= 2 mm larger than the nominal frame diameter had 72% sensitivity and 61% specificity to predict PAVR. In conclusion, in patients undergoing TAVI, >= 2-mm difference between maximum aortic annulus and nominal prosthesis diameters and depth of the frame into the left ventricular outflow tract of <2 mm are independently associated with PAVR >= 2+. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1800 / 1806
页数:7
相关论文
共 50 条
  • [41] Predictive Value of Calcium Volume Measurement Determined by Computed Tomography for Paravalvular Leakage After Transcatheter Aortic Valve Implantation
    Isomatsu, Daisuke
    Sato, Akihiko
    Muto, Yuki
    Abe, Satoshi
    Misaka, Tomofumi
    Oikawa, Masayoshi
    Kobayashi, Atsushi
    Yoshihisa, Akiomi
    Nakazato, Kazuhiko
    Ishida, Takafumi
    Sekino, Hirofumi
    Fukushima, Kenji
    Ito, Hiroshi
    Takeishi, Yasuchika
    CIRCULATION, 2022, 146
  • [42] Iodine contrast volume reduction in preoperative transcatheter aortic valve implantation computed tomography: Comparison with 64and 256-multidetector row computed tomography
    Yoshiura, T.
    Masuda, T.
    Kobayashi, Y.
    Kikuhara, Y.
    Ishibashi, T.
    Nonaka, H.
    Oku, T.
    Sato, T.
    Funama, Y.
    RADIOGRAPHY, 2024, 30 (01) : 408 - 415
  • [43] Impact of paravalvular regurgitation in morbimortality of patients undergoing transcatheter aortic valve implantation
    Alzira Nunes, A.
    Torres, S.
    Braga, M.
    Maia Araujo, P.
    Rodrigues, J.
    Pinto, R.
    Andre Rodrigues, R.
    Bernardo Almeida, P.
    Magalhaes, D.
    Campelo, M. Belchior
    Carlos Silva, J.
    Julia Maciel, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 491 - 491
  • [44] Correlates on MSCT of Paravalvular Aortic Regurgitation After Transcatheter Aortic Valve Implantation Using the Medtronic CoreValve Prosthesis
    Schultz, Carl J.
    Tzikas, Apostolos
    Moelker, Adriaan
    Rossi, Alexia
    Nuis, Rutger-Jan
    Geleijnse, Marcel M.
    van Mieghem, Nicolas
    Krestin, Gabriel P.
    de Feyter, Pim
    Serruys, Patrick W.
    de Jaegere, Peter P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (03) : 446 - 455
  • [45] Percutaneous paravalvular leak closure for aortic regurgitation after transcatheter aortic valve
    Castro, M. Mariana
    Abecasis, J. P.
    Teles, R. C.
    Ribeiras, R.
    Freitas, P.
    Neto, M.
    Almeida, M.
    Andrade, M. J.
    Mendes, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 : 182 - 182
  • [46] Evaluation and Management of Paravalvular Aortic Regurgitation After Transcatheter Aortic Valve Replacement
    Sinning, Jan-Malte
    Vasa-Nicotera, Mariuca
    Chin, Derek
    Hammerstingl, Christoph
    Ghanem, Alexander
    Bence, Johan
    Kovac, Jan
    Grube, Eberhard
    Nickenig, Georg
    Werner, Nikos
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (01) : 11 - 20
  • [47] Prediction of paravalvular leakage after transcatheter aortic valve implantation
    Luigi F. M. Di Martino
    Wim B. Vletter
    Ben Ren
    Carl Schultz
    Nicolas M. Van Mieghem
    Osama I. I. Soliman
    Matteo Di Biase
    Peter P. de Jaegere
    Marcel L. Geleijnse
    The International Journal of Cardiovascular Imaging, 2015, 31 : 1461 - 1468
  • [48] Prediction of paravalvular leakage after transcatheter aortic valve implantation
    Di Martino, Luigi F. M.
    Vletter, Wim B.
    Ren, Ben
    Schultz, Carl
    Van Mieghem, Nicolas M.
    Soliman, Osama I. I.
    Di Biase, Matteo
    de Jaegere, Peter P.
    Geleijnse, Marcel L.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (07): : 1461 - 1468
  • [49] Paravalvular leak after transcatheter aortic valve implantation Reply
    Karaduman, Bilge Duran
    Ayhan, Huseyin
    Keles, Telat
    Bozkurt, Engin
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2020, 24 (03): : 211 - 212
  • [50] Challenges in transcatheter valve treatment: aortic regurgitation after transcatheter aortic valve implantation
    Sinning, Jan-Malte
    Werner, Nikos
    Nickenig, Georg
    Grube, Eberhard
    EUROINTERVENTION, 2013, 9 : S72 - S76