Multidetector Row Computed Tomography Parameters Associated With Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation

被引:18
|
作者
Katsanos, Spyridon [1 ]
Ewe, See Hooi [1 ]
Debonnaire, Philippe [1 ]
van der Kley, Frank [1 ]
de Weger, Arend [2 ]
Palmen, Meindert [2 ]
Scholte, Arthur J. H. A. [1 ]
Schalij, Martin J. [1 ]
Bax, Jeroen J. [1 ]
Marsan, Nina Ajmone [1 ]
Delgado, Victoria [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Cardiothorac Surg, Leiden, Netherlands
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2013年 / 112卷 / 11期
关键词
EAE/ASE RECOMMENDATIONS; EUROPEAN-ASSOCIATION; REPLACEMENT; STENOSIS; OUTCOMES; IMPACT; ECHOCARDIOGRAPHY; INTERVENTIONS; METAANALYSIS; PREDICTORS;
D O I
10.1016/j.amjcard.2013.07.049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multidetector row computed tomographic (MDCT) assessment of aortic annulus dimensions and frame position and deployment have been associated with paravalvular aortic regurgitation (PAVR) after transcatheter aortic valve implantation (TAVI). The present evaluation investigated the (pre- and postprocedure) MDCT associates of PAVR >= 2+. In total, 123 patients referred for TAVI underwent clinical evaluation, transthoracic echocardiography, and pre- and post-TAVI MDCT. Pre-TAVI MDCT measurements of the aortic annular dimensions and post-TAVI MDCT evaluation of the position and deployment of the prosthesis in the native annulus were performed. At 1-month follow-up, PAVR +/- 2+ was observed in 25 patients (20%). The difference between the MDCT-derived maximum aortic annulus and the nominal diameters of the implanted prosthesis (odds ratio 1.912, p = 0.002) and shallow position of the frame in the left ventricular outflow tract (<2 mm) (odds ratio 4.865, p = 0.017) were independently related to significant PAVR. A maximum annulus diameter >= 2 mm larger than the nominal frame diameter had 72% sensitivity and 61% specificity to predict PAVR. In conclusion, in patients undergoing TAVI, >= 2-mm difference between maximum aortic annulus and nominal prosthesis diameters and depth of the frame into the left ventricular outflow tract of <2 mm are independently associated with PAVR >= 2+. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1800 / 1806
页数:7
相关论文
共 50 条
  • [31] Implications of aortic valve calcification for paravalvular aortic regurgitation post-transcatheter aortic valve implantation
    Ewe, S. H.
    Ng, A. C. T.
    Schuijf, J. D.
    Van der Kley, F.
    Colli, A.
    De Weger, A.
    Marsan, N. A.
    Schalij, M. J.
    Bax, J. J.
    Delgado, V.
    EUROPEAN HEART JOURNAL, 2011, 32 : 889 - 889
  • [32] Aortic regurgitation after transcatheter aortic valve implantation
    Costopoulos, Charis
    Naganuma, Toru
    Latib, Azeem
    Colombo, Antonio
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (09) : 1089 - 1092
  • [33] Impact of tricuspid annular shape on late worsening tricuspid regurgitation after transcatheter aortic implantation: insight from multidetector row computed tomography assessment
    Hirasawa, K.
    Fortuni, F.
    Rosendael, P. J.
    Marsan, N. Ajmone
    Delgado, V.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2021, 42 : 175 - 175
  • [34] THREE-DIMENSIONAL AORTIC ANNULAR ASSESSMENT BY MULTIDETECTOR COMPUTED TOMOGRAPHY PREDICTS MODERATE OR SEVERE PARAVALVULAR REGURGITATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT: A MULTICENTER RETROSPECTIVE ANALYSIS
    Willson, Alex
    Webb, John
    LaBounty, Troy
    Achenbach, Stephan
    Moss, Robert
    Wheeler, Miriam
    Thompson, Christopher
    Min, James
    Gurvitch, Ronen
    Norgard, Bjarne
    Toggweiler, Stefan
    Binder, Ronald K.
    Hague, Cameron
    Freeman, Melanie
    Poulter, Steen H.
    Poulter, Rohen
    Wood, David
    Jonathon, Leipsic
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E325 - E325
  • [35] 3-Dimensional Aortic Annular Assessment by Multidetector Computed Tomography Predicts Moderate or Severe Paravalvular Regurgitation After Transcatheter Aortic Valve Replacement A Multicenter Retrospective Analysis
    Willson, Alexander B.
    Webb, John G.
    LaBounty, Troy M.
    Achenbach, Stephan
    Moss, Robert
    Wheeler, Miriam
    Thompson, Christopher
    Min, James K.
    Gurvitch, Ronen
    Norgaard, Bjarne L.
    Hague, Cameron J.
    Toggweiler, Stefan
    Binder, Ronald
    Freeman, Melanie
    Poulter, Rohan
    Poulsen, Steen
    Wood, David A.
    Leipsic, Jonathon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) : 1287 - 1294
  • [36] Impact of Different Iterations of Devices and Degree of Aortic Valve Calcium on Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
    Kong, William K. F.
    van Rosendael, Philippe J.
    van der Kley, Frank
    de Weger, Arend
    Kamperidis, Vasileios
    Regeer, Madelien V.
    Marsan, Nina Ajmone
    Box, Jeroen J.
    Delgado, Victoria
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 118 (04): : 567 - 571
  • [37] Trace To mild paravalvular regurgitation after transcatheter aortic valve implantation (TAVI): a multivariante analysis
    Stelzmueller, M. -E.
    Mirschinka, K.
    Sandner, S.
    Mora, B.
    Laufer, G.
    Wisser, W.
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 : S60 - S61
  • [38] Combined percutaneous closure of paravalvular leaks and intraprosthetic regurgitation after transcatheter aortic valve implantation
    Citro, Rodolfo
    Attisano, Tiziana
    Vigorito, Francesco
    Cavallo, Armando Ugo
    Vitale, Giovanni
    Coccia, Michela
    Santoro, Giuseppe
    Giudice, Pietro
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 175 (03) : E48 - E51
  • [39] Five-year outcomes of mild paravalvular regurgitation after transcatheter aortic valve implantation
    Okuno, Taishi
    Tomii, Daijiro
    Heg, Dik
    Lanz, Jonas
    Praz, Fabien
    Stortecky, Stefan
    Reineke, David
    Windecker, Stephan
    Pilgrim, Thomas
    EUROINTERVENTION, 2022, 18 (01) : 33 - +
  • [40] New methodology for paravalvular aortic regurgitation assessment in the era of transcatheter aortic valve implantation
    Goncalves, A.
    Almeria, C.
    Marcos-Alberca, P.
    Feltes, G.
    Hernandez-Antolin, R.
    Rodriguez, E.
    Garcia, E.
    Silva Cardoso, J.
    Macaya, C.
    Zamorano, J.
    EUROPEAN HEART JOURNAL, 2011, 32 : 186 - 186