Evaluation and Management of Paravalvular Aortic Regurgitation After Transcatheter Aortic Valve Replacement

被引:154
|
作者
Sinning, Jan-Malte [1 ]
Vasa-Nicotera, Mariuca [1 ]
Chin, Derek [2 ]
Hammerstingl, Christoph [1 ]
Ghanem, Alexander [1 ]
Bence, Johan [2 ]
Kovac, Jan [2 ]
Grube, Eberhard [1 ]
Nickenig, Georg [1 ]
Werner, Nikos [1 ]
机构
[1] Univ Klinikum Bonn, Med Klin & Poliklin 2, D-53105 Bonn, Germany
[2] Glenfield Univ Hosp, Dept Cardiol, Leicester, Leics, England
关键词
ARI; paravalvular aortic regurgitation; periprosthetic regurgitation; TAVI; TAVR; HIGH-RISK PATIENTS; IN-VALVE; COMPUTED-TOMOGRAPHY; COREVALVE PROSTHESIS; IMPLANTATION; STENOSIS; OUTCOMES; REGISTRY; IMPACT; ECHOCARDIOGRAPHY;
D O I
10.1016/j.jacc.2013.02.088
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Paravalvular aortic regurgitation (PAR) negatively affects the prognosis after transcatheter aortic valve replacement (TAVR) with dramatically increased morbidity and mortality in patients with more than mild PAR. Because transcatheter heart valves are implanted in a sutureless fashion using oversizing to anchor the prosthesis stent frame at the level of the virtual aortic annulus, stent frame underexpansion due to heavily calcified cusps, suboptimal placement of the prosthesis, and/or annulus-prosthesis-size mismatch due to malsizing can contribute to paravalvular leakage. In contrast to open heart surgery, TAVR does not offer the opportunity to measure the aortic annulus under direct vision during the procedure. Therefore, the dilemma before each TAVR procedure is the appropriate sizing of the dimensions of the aortic annulus and to choose not only the size but also the transcatheter heart valve type (self-expanding vs. balloon-expandable) that fits the given anatomy best. Because precise echocardiographic quantification of PAR in patients with TAVR remains challenging especially in the acute implantation situation, a multimodal approach for the evaluation of PAR with the use of hemodynamic measurements and imaging modalities is imperative to precisely quantify the severity of aortic regurgitation immediately after valve implantation and to identify patients who will benefit from corrective measures such as post-dilation or valve-in-valve implantation. Every measure has to be taken to prevent or reduce PAR to provide a satisfying long-term clinical outcome. (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [1] Paravalvular aortic regurgitation after transcatheter aortic valve replacement
    Bugan, Baris
    Tuzcu, Emin Murat
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2014, 42 (01): : 83 - 93
  • [2] Transseptal Approach for the Management of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement
    Martinez, Claudia A.
    O'Neill, Brian
    Singh, Vikas
    O'Neill, William W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (04) : E587 - E591
  • [3] Management of Paravalvular Regurgitation After Edwards SAPIEN Transcatheter Aortic Valve Replacement
    Martinez, Claudia A.
    Singh, Vikas
    O'Neill, Brian P.
    Alfonso, Carlos E.
    Bilsker, Martin S.
    Clark, Pedro Martinez
    Williams, Donald
    Cohen, Mauricio G.
    Heldman, Alan W.
    O'Neill, William W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (02) : 300 - 311
  • [4] CARDIAC MRI IN ASSESSMENT OF PARAVALVULAR AORTIC REGURGITATION AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT
    Aman, Wahaj
    Zhan, Yang
    Shah, Dipan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2996 - 2996
  • [5] AORTIC VALVE CALCIFICATION PREDICTS PARAVALVULAR AORTIC REGURGITATION AFTER SELF-EXPANDING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Agha, Ahmad
    Ali, Nisreen
    Memon, Shermeen
    Bakhos, Lara
    Dajani, Khaled
    Rabbat, Mark
    Leya, Ferdinand
    Syed, Mushabbar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1506 - 1506
  • [6] Prevention and management of paravalvular regurgitation after transcatheter aortic valve implantation
    Chung, Christine J.
    Otto, Catherine M.
    EUROPEAN HEART JOURNAL, 2023, 44 (15) : 1340 - 1342
  • [7] TRANSCATHETER AORTIC VALVE REPLACEMENT CUSTOMIZATION BASED ON PARAVALVULAR AORTIC REGURGITATION LOCATION
    Gilbert, Olivia N.
    Hermann, Daniel D.
    Alvarez, Lucia
    Deutsch, Christian
    Aldrich, Alex
    Sacrinty, Matthew
    Pu, Min
    Stacey, Richard
    Applegate, Robert
    Gandhi, Sanjay
    Zhao, David
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1791 - A1791
  • [8] Quantifying Paravalvular Aortic Regurgitation in Transcatheter Aortic Valve Replacement The Pursuit of Perfection
    Kapadia, Samir R.
    Harb, Serge C.
    Krishnaswamy, Amar
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (03) : 298 - 300
  • [9] Transcatheter Aortic Valve Replacement, Paravalvular Regurgitation, and the Cardiac Sonographer
    Rampoldi, James
    Kallstrom, Eric
    Despino, Jason
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (04) : CP12 - 680
  • [10] Paravalvular leak after transcatheter aortic valve replacement
    Genereux, P.
    Kodali, S.
    Hahn, R.
    Nazif, T.
    Williams, M. R.
    Leon, M. B.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (05): : 529 - 537