Evaluation and Management of Paravalvular Aortic Regurgitation After Transcatheter Aortic Valve Replacement

被引:154
|
作者
Sinning, Jan-Malte [1 ]
Vasa-Nicotera, Mariuca [1 ]
Chin, Derek [2 ]
Hammerstingl, Christoph [1 ]
Ghanem, Alexander [1 ]
Bence, Johan [2 ]
Kovac, Jan [2 ]
Grube, Eberhard [1 ]
Nickenig, Georg [1 ]
Werner, Nikos [1 ]
机构
[1] Univ Klinikum Bonn, Med Klin & Poliklin 2, D-53105 Bonn, Germany
[2] Glenfield Univ Hosp, Dept Cardiol, Leicester, Leics, England
关键词
ARI; paravalvular aortic regurgitation; periprosthetic regurgitation; TAVI; TAVR; HIGH-RISK PATIENTS; IN-VALVE; COMPUTED-TOMOGRAPHY; COREVALVE PROSTHESIS; IMPLANTATION; STENOSIS; OUTCOMES; REGISTRY; IMPACT; ECHOCARDIOGRAPHY;
D O I
10.1016/j.jacc.2013.02.088
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Paravalvular aortic regurgitation (PAR) negatively affects the prognosis after transcatheter aortic valve replacement (TAVR) with dramatically increased morbidity and mortality in patients with more than mild PAR. Because transcatheter heart valves are implanted in a sutureless fashion using oversizing to anchor the prosthesis stent frame at the level of the virtual aortic annulus, stent frame underexpansion due to heavily calcified cusps, suboptimal placement of the prosthesis, and/or annulus-prosthesis-size mismatch due to malsizing can contribute to paravalvular leakage. In contrast to open heart surgery, TAVR does not offer the opportunity to measure the aortic annulus under direct vision during the procedure. Therefore, the dilemma before each TAVR procedure is the appropriate sizing of the dimensions of the aortic annulus and to choose not only the size but also the transcatheter heart valve type (self-expanding vs. balloon-expandable) that fits the given anatomy best. Because precise echocardiographic quantification of PAR in patients with TAVR remains challenging especially in the acute implantation situation, a multimodal approach for the evaluation of PAR with the use of hemodynamic measurements and imaging modalities is imperative to precisely quantify the severity of aortic regurgitation immediately after valve implantation and to identify patients who will benefit from corrective measures such as post-dilation or valve-in-valve implantation. Every measure has to be taken to prevent or reduce PAR to provide a satisfying long-term clinical outcome. (C) 2013 by the American College of Cardiology Foundation
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [21] Paravalvular Regurgitation After Transcatheter Aortic Valve Replacement Striving to Perfect its Prognostic Evaluation With Hemodynamic Data
    Jilaihawi, Hasan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07) : 712 - 714
  • [22] 3-Dimensional printing to predict paravalvular regurgitation after transcatheter aortic valve replacement
    Reiff, Christopher
    Zhingre Sanchez, Jorge D.
    Mattison, Lars M.
    Iaizzo, Paul A.
    Garcia, Santiago
    Raveendran, Ganesh
    Gurevich, Sergey
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (07) : E703 - E710
  • [23] Percutaneous Closure of Paravalvular Regurgitation After Third-Generation Transcatheter Aortic Valve Replacement
    Onorato, Eustaquio Maria
    Vercellino, Matteo
    Costante, Anna Maria
    Cioppa, Angelo
    Sada, Lidia
    Santoro, Alessandro
    Popusoi, Gregory
    Tesorio, Tullio
    INTERNATIONAL HEART JOURNAL, 2021, 62 (06) : 1403 - 1410
  • [24] Assessment of the Severity of Paravalvular Regurgitation and its Role on Survival After Transcatheter Aortic Valve Replacement
    Sannino, Anna
    Stoler, Robert C.
    Vallabhan, Ravi
    Potluri, Srinivasa
    Pollock, Benjamin
    Filardo, Giovanni
    Mack, Michael J.
    Grayburn, Paul A.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (01): : 24 - 30
  • [25] Alteration of von Willebrand Factor after Transcatheter Aortic Valve Replacement in the Absence of Paravalvular Regurgitation
    Pawlitschek, Felix
    Keyl, Cornelius
    Zieger, Barbara
    Budde, Ulrich
    Beyersdorf, Friedhelm
    Neumann, Franz-Josef
    Stratz, Christian
    Nuehrenberg, Thomas G.
    Trenk, Dietmar
    THROMBOSIS AND HAEMOSTASIS, 2018, 118 (01) : 103 - 111
  • [26] Outcomes of Mild Aortic Regurgitation After Transcatheter Aortic Valve Replacement
    Chahine, Johnny
    Kadri, Amer N.
    Gajulapalli, Rama Dilip
    Lak, Hassan
    Krishnaswamy, Amar
    Reed, Grant
    Perez, Oscar
    Puri, Rishi
    Popovic, Zoran
    Verma, Beni Rai
    Kaur, Manpreet
    Gad, Mohamed M.
    Nair, Raunak M.
    Jaber, Wael
    Yun, James
    Schoenhagen, Paul
    Harb, Serge C.
    Tuzcu, E. Murat
    Svensson, Lars G.
    Kapadia, Samir R.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2021, 5 (02): : 201 - 207
  • [27] Management of mitral regurgitation and transcatheter aortic valve replacement
    Unger, Philippe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 288 : 59 - 60
  • [28] Progression and Prognosis of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
    Meneguz-Moreno, Rafael Alexandre
    de Castro-Filho, Antonio
    de Oliveira Ramos, Auristela Isabel
    Zumarraga, Mayra
    Le Bihan, David
    Barretto, Rodrigo
    de Alvim Siqueira, Dimytri Alexandre
    Cunha Abizaid, Alexandre Antonio
    de Moraes Rego Sousa, Amanda Guerra
    Eduardo Sousa, J.
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2017, 109 (06) : 590 - 598
  • [29] Paravalvular Regurgitation Following Transcatheter Aortic Valve Replacement: Is it Still an Issue in 2018?
    Pibarot, Philippe
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (01): : 31 - 33
  • [30] Mitral regurgitation after transcatheter aortic valve replacement
    Nappi, Francesco
    Nenna, Antonio
    Timofeeva, Irina
    Mihos, Christos
    Gentile, Federico
    Chello, Massimo
    JOURNAL OF THORACIC DISEASE, 2020, 12 (05) : 2926 - 2935