Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose

被引:49
|
作者
Sui, Xin [1 ]
Meinel, Felix G. [2 ,3 ]
Song, Wei [1 ]
Xu, Xiaoli [1 ]
Wang, Zixing [4 ,5 ]
Wang, Yuyan [4 ,5 ]
Jin, Zhengyu [1 ]
Chen, Jiuhong [6 ]
Vliegenthart, Rozemarijn [2 ,7 ]
Schoepf, U. Joseph [2 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China
[2] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[3] Univ Munich, Dept Clin Radiol, Munich, Germany
[4] Chinese Acad Med Sci, Inst Basic Med Sci, Dept Epidemiol & Biostat, Beijing 100730, Peoples R China
[5] Peking Union Med Coll, Sch Basic Med, Beijing, Peoples R China
[6] Siemens China, Beijing, Peoples R China
[7] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging North East Netherlands, Dept Radiol, Groningen, Netherlands
关键词
Imaging; Three-Dimensional; Solitary Pulmonary Nodule; Computed Tomography; radiation dosage; LUNG-CANCER; CHEST; OBSERVER; TOMOSYNTHESIS; RADIOGRAPHY; VOLUMETRY; TIME;
D O I
10.1016/j.ejrad.2015.12.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In this study, the accuracy of ultra-low-dose computed tomography (CT) with iterative reconstruction (IR) for detection and measurement of pulmonary nodules was evaluated. Methods: Eighty-four individuals referred for lung cancer screening (mean age: 54.5 +/- 10.8 years) underwent low-dose computed tomography (LDCT) and ultra-low-dose CT. CT examinations were performed with attenuation-based tube current modulation. Reference tube voltage and current were set to 120 kV/25 mAs for LDCT and 80 kV/4 mAs for ultra-low-dose CT. CT images were reconstructed with filtered back projection (FBP) for LDCT, and with FBP and IR for ultra-low-dose CT datasets. A reference standard was established by a consensus panel of 2 different radiologists on LDCT. Volume and diameter of the solid nodules were measured on LDCT with FBP and ultra-low dose CT with FBP and IR. Interobserver and interscan variability were analyzed and compared by the Bland-Altman method. Results: A total of 127 nodules were identified, including 105 solid nodules, 15 part solid nodules, 7 ground glass nodules. On ultra-low-dose CT scans, the effective radiation dose was 0.13 +/- 0.11 mSv. A total of 113 (88.9%) and 110 (86.6%) true-positive nodules with FBP versus 117 (92.1%) and 118(92.9%) with IR were detected by two observers, respectively. The volume and size of the 105 solid nodules were measured, with mean volume/diameter of 46.5 +/- 46.6 mm(3) /5.1 +/- 1.6 mm. There was no significant difference in nodule volume or diameter measurements between ultra-low-dose CT and LDCT protocols for solid nodules. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [21] Adaptive Statistical Iterative Reconstruction-Applied Ultra-Low-Dose CT with Radiography-Comparable Radiation Dose: Usefulness for Lung Nodule Detection
    Yoon, Hyun Jung
    Chung, Myung Jin
    Hwang, Hye Sun
    Moon, Jung Won
    Lee, Kyung Soo
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1132 - 1141
  • [22] Diagnostic accuracy of low-dose and ultra-low-dose CT in detection of chest pathology: a systematic review
    Taekker, Maria
    Kristjansdottir, Bjorg
    Graumann, Ole
    Laursen, Christian B.
    Pietersen, Pia, I
    CLINICAL IMAGING, 2021, 74 : 139 - 148
  • [23] Lung nodules are reliably detectable on ultra-low-dose CT utilising model-based iterative reconstruction with radiation equivalent to plain radiography
    Miller, A. R.
    Jackson, D.
    Hui, C.
    Deshpande, S.
    Kuo, E.
    Hamilton, G. S.
    Lau, K. K.
    CLINICAL RADIOLOGY, 2019, 74 (05) : 409.e17 - 409.e22
  • [24] Value of deep learning reconstruction at ultra-low-dose CT for evaluation of urolithiasis
    Zhang, Gumuyang
    Zhang, Xiaoxiao
    Xu, Lili
    Bai, Xin
    Jin, Ru
    Xu, Min
    Yan, Jing
    Jin, Zhengyu
    Sun, Hao
    EUROPEAN RADIOLOGY, 2022, 32 (09) : 5954 - 5963
  • [25] Value of deep learning reconstruction at ultra-low-dose CT for evaluation of urolithiasis
    Gumuyang Zhang
    Xiaoxiao Zhang
    Lili Xu
    Xin Bai
    Ru Jin
    Min Xu
    Jing Yan
    Zhengyu Jin
    Hao Sun
    European Radiology, 2022, 32 : 5954 - 5963
  • [26] Ultra-low-dose cone-beam CT compared to standard dose in the assessment for acute fractures
    M. C. Murphy
    B. Gibney
    J. Walsh
    G. Orpen
    E. Kenny
    F. Bolster
    P. J. MacMahon
    Skeletal Radiology, 2022, 51 : 153 - 159
  • [27] Value of ultra-low-dose chest CT with iterative reconstruction for selected emergency room patients with acute dyspnea
    Macri, Francesco
    Greffier, Joel
    Pereira, Fabricio
    Rosa, Alina Chica
    Khasanova, Elina
    Claret, Pierre-Geraut
    Larbi, Ahmed
    Gualdi, Gianfranco
    Beregi, Jean Paul
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (09) : 1637 - 1644
  • [28] Ultra-low-dose cone-beam CT compared to standard dose in the assessment for acute fractures
    Murphy, M. C.
    Gibney, B.
    Walsh, J.
    Orpen, G.
    Kenny, E.
    Bolster, F.
    MacMahon, P. J.
    SKELETAL RADIOLOGY, 2022, 51 (01) : 153 - 159
  • [29] Ultra-low-dose CT for left atrium and pulmonary veins imaging using new model-based iterative reconstruction algorithm
    Annoni, A. D.
    Andreini, D.
    Pontone, G.
    Formenti, A.
    Petulla, M.
    Consiglio, E.
    Nobili, E.
    Baggiano, A.
    Conte, E.
    Mushtaq, S.
    Bertella, E.
    Billi, F.
    Bartorelli, A. L.
    Montorsi, P.
    Pepi, M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (12) : 1366 - 1373
  • [30] ULTRA-LOW-DOSE HEPARIN
    不详
    LANCET, 1980, 1 (8174): : 907 - 908