Ultra-low-dose CT for left atrium and pulmonary veins imaging using new model-based iterative reconstruction algorithm

被引:24
|
作者
Annoni, A. D. [1 ]
Andreini, D. [1 ,2 ]
Pontone, G. [1 ]
Formenti, A. [1 ]
Petulla, M. [1 ]
Consiglio, E. [1 ]
Nobili, E. [1 ]
Baggiano, A. [1 ]
Conte, E. [1 ]
Mushtaq, S. [1 ]
Bertella, E. [1 ]
Billi, F. [1 ]
Bartorelli, A. L. [1 ,2 ]
Montorsi, P. [1 ,2 ]
Pepi, M. [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, I-20138 Milan, Italy
[2] Univ Milan, Dept Cardiovasc Sci & Community Hlth, Milan, Italy
关键词
computed tomography imaging; left atrium; atrial fibrillation; dose-reducing software; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; FILTERED BACK-PROJECTION; MULTIDETECTOR ROW CT; DIAGNOSTIC-ACCURACY; REDUCTION; QUALITY; MANAGEMENT; ABLATION;
D O I
10.1093/ehjci/jev103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To evaluate the feasibility of ultra-low-dose CT for left atrium and pulmonary veins using new model-based iterative reconstruction (MBIR) algorithm. Methods and results Two hundred patients scheduled for catheter ablation were randomized into two groups: Group 1 (100 patients, Multidetector row CT (MDCT) with MBIR, no ECG triggering, tube voltage and tube current of 100 kV and 60 mA, respectively) and Group 2 [100 patients, MDCT with adaptive statistical iterative reconstruction algorithm (ASIR), no ECG triggering, and kV and mA tailored on patient BMI]. Image quality, CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) of left atrium (LA) and pulmonary veins, and effective dose (ED) were evaluated for each exam and compared between two groups. No significant differences between groups in terms of population characteristics, cardiovascular risk factors, anatomical features, prevalence of persistent atrial fibrillation and image quality score. Statistically significant differences were found between Group 1 and Group 2 in mean attenuation, SNR, and CNR of LA. Significantly, lower values of noise were found in Group 1 versus Group 2. Group 1 showed a significantly lower mean ED in comparison with Group 2 (0.41 +/- 0.04 versus 4.17 +/- 2.7 mSv). Conclusion The CT for LA and pulmonary veins imaging using MBIR is feasible and allows examinations with very low-radiation exposure without loss of image quality.
引用
收藏
页码:1366 / 1373
页数:8
相关论文
共 50 条
  • [1] Feasibility of an ultra low dose CT for left atrium and pulmonary veins imaging using a new model-based iterative reconstruction
    Annoni, A.
    Andreini, D.
    Formenti, A.
    Pontone, G.
    Mushtaq, S.
    Bertella, E.
    Petulla, M.
    Nobili, E.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 200 - 200
  • [2] Ultra low dose CT for left atrium and pulmonary veins imaging using VEO (model-based iterative reconstruction)
    Annoni, A.
    Formenti, A.
    Andreini, D.
    Pontone, G.
    Petulla', M.
    Ballerini, G.
    Nobili, E.
    Baggiano, A.
    Mushtaq, S.
    Pepi, M.
    EUROPEAN HEART JOURNAL, 2013, 34 : 845 - 845
  • [3] Ultra-Low-Dose Fetal CT With Model-Based Iterative Reconstruction: A Prospective Pilot Study
    Imai, Rumi
    Miyazaki, Osamu
    Horiuchi, Tetsuya
    Asano, Keisuke
    Nishimura, Gen
    Sago, Haruhiko
    Nosaka, Shunsuke
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (06) : 1358 - 1365
  • [4] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [5] Evaluation of an iterative model-based CT reconstruction algorithm by intra-patient comparison of standard and ultra-low-dose examinations
    Noel, Peter B.
    Engels, Stephan
    Koehler, Thomas
    Muenzel, Daniela
    Franz, Daniela
    Rasper, Michael
    Rummeny, Ernst J.
    Dobritz, Martin
    Fingerle, Alexander A.
    ACTA RADIOLOGICA, 2018, 59 (10) : 1225 - 1231
  • [6] Pulmonary Emphysema Quantification on Ultra-Low-Dose Computed Tomography Using Model-Based Iterative Reconstruction With or Without Lung Setting
    Hata, Akinori
    Yanagawa, Masahiro
    Kikuchi, Noriko
    Honda, Osamu
    Tomiyama, Noriyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (05) : 760 - 766
  • [7] Ultra-low-dose lung screening CT with model-based iterative reconstruction: an assessment of image quality and lesion conspicuity
    Ju, Yun Hye
    Lee, Geewon
    Lee, Jiwon
    Hong, Seung Baek
    Suh, Young Ju
    Jeong, Yeon Joo
    ACTA RADIOLOGICA, 2018, 59 (05) : 553 - 559
  • [8] Hybrid and Model-Based Iterative Reconstruction Influences the Volumetry of Visceral and Subcutaneous Adipose Tissue on Ultra-Low-Dose CT
    Lambert, Lukas
    Novak, Matej
    Siklova, Michaela
    Krauzova, Eva
    Stich, Vladimir
    Burgetova, Andrea
    OBESITY, 2020, 28 (11) : 2083 - 2089
  • [9] Application of a full model-based iterative reconstruction (MBIR) in 80 kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients
    Jihang Sun
    Qifeng Zhang
    Xiaomin Duan
    Chengyue Zhang
    Pengpeng Wang
    Chenguang Jia
    Yong Liu
    Yun Peng
    La radiologia medica, 2018, 123 : 117 - 124
  • [10] Application of a full model-based iterative reconstruction (MBIR) in 80 kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients
    Sun, Jihang
    Zhang, Qifeng
    Duan, Xiaomin
    Zhang, Chengyue
    Wang, Pengpeng
    Jia, Chenguang
    Liu, Yong
    Peng, Yun
    RADIOLOGIA MEDICA, 2018, 123 (02): : 117 - 124