Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose

被引:49
|
作者
Sui, Xin [1 ]
Meinel, Felix G. [2 ,3 ]
Song, Wei [1 ]
Xu, Xiaoli [1 ]
Wang, Zixing [4 ,5 ]
Wang, Yuyan [4 ,5 ]
Jin, Zhengyu [1 ]
Chen, Jiuhong [6 ]
Vliegenthart, Rozemarijn [2 ,7 ]
Schoepf, U. Joseph [2 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China
[2] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[3] Univ Munich, Dept Clin Radiol, Munich, Germany
[4] Chinese Acad Med Sci, Inst Basic Med Sci, Dept Epidemiol & Biostat, Beijing 100730, Peoples R China
[5] Peking Union Med Coll, Sch Basic Med, Beijing, Peoples R China
[6] Siemens China, Beijing, Peoples R China
[7] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging North East Netherlands, Dept Radiol, Groningen, Netherlands
关键词
Imaging; Three-Dimensional; Solitary Pulmonary Nodule; Computed Tomography; radiation dosage; LUNG-CANCER; CHEST; OBSERVER; TOMOSYNTHESIS; RADIOGRAPHY; VOLUMETRY; TIME;
D O I
10.1016/j.ejrad.2015.12.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In this study, the accuracy of ultra-low-dose computed tomography (CT) with iterative reconstruction (IR) for detection and measurement of pulmonary nodules was evaluated. Methods: Eighty-four individuals referred for lung cancer screening (mean age: 54.5 +/- 10.8 years) underwent low-dose computed tomography (LDCT) and ultra-low-dose CT. CT examinations were performed with attenuation-based tube current modulation. Reference tube voltage and current were set to 120 kV/25 mAs for LDCT and 80 kV/4 mAs for ultra-low-dose CT. CT images were reconstructed with filtered back projection (FBP) for LDCT, and with FBP and IR for ultra-low-dose CT datasets. A reference standard was established by a consensus panel of 2 different radiologists on LDCT. Volume and diameter of the solid nodules were measured on LDCT with FBP and ultra-low dose CT with FBP and IR. Interobserver and interscan variability were analyzed and compared by the Bland-Altman method. Results: A total of 127 nodules were identified, including 105 solid nodules, 15 part solid nodules, 7 ground glass nodules. On ultra-low-dose CT scans, the effective radiation dose was 0.13 +/- 0.11 mSv. A total of 113 (88.9%) and 110 (86.6%) true-positive nodules with FBP versus 117 (92.1%) and 118(92.9%) with IR were detected by two observers, respectively. The volume and size of the 105 solid nodules were measured, with mean volume/diameter of 46.5 +/- 46.6 mm(3) /5.1 +/- 1.6 mm. There was no significant difference in nodule volume or diameter measurements between ultra-low-dose CT and LDCT protocols for solid nodules. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [31] ULTRA-LOW-DOSE HEPARIN
    JAQUES, LB
    HIEBERT, LM
    MAHADOO, J
    WRIGHT, CJ
    LANCET, 1980, 2 (8208): : 1369 - 1369
  • [32] Ultra-low-dose multislice spiral CT colonography
    Iannaccone, R
    Laghi, A
    Mangiapane, F
    Trenna, S
    Piacentini, F
    Passariello, R
    RADIOLOGY, 2002, 225 : 585 - 585
  • [33] Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra-Low-Dose Chest CT
    Jiang, Beibei
    Li, Nianyun
    Shi, Xiaomeng
    Zhang, Shuai
    Li, Jianying
    de Bock, Geertruida H.
    Vliegenthart, Rozemarijn
    Xie, Xueqian
    RADIOLOGY, 2022, 303 (01) : 202 - 212
  • [34] Ultra-low-dose CT lung screening with artificial intelligence iterative reconstruction: evaluation via automatic nodule-detection software
    Yang, L.
    Liu, H.
    Han, J.
    Xu, S.
    Zhang, G.
    Wang, Q.
    Du, Y.
    Yang, F.
    Zhao, X.
    Shi, G.
    CLINICAL RADIOLOGY, 2023, 78 (07) : 525 - 531
  • [35] Matched Pair Validation of Ultra-low-dose CT Compared to Low-dose CT for Oncologic 18F-FDG PET/CT
    Hall, N. C.
    Wright, C. L.
    Gortanla, N.
    Nagar, V.
    Zhang, J.
    Knopp, M. V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S322 - S322
  • [36] LUNGE THORAX - Ultra-Low-Dose CT for the Detection of Round Lung Lesions
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (11):
  • [37] URO - low-dose vs. ultra-low-dose CT in the diagnosis of urolithiasis
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (01): : 18 - 19
  • [38] An AI deep learning algorithm for detecting pulmonary nodules on ultra-low-dose CT in an emergency setting: a reader study
    Inge A. H. van den Berk
    Colin Jacobs
    Maadrika M. N. P. Kanglie
    Onno M. Mets
    Miranda Snoeren
    Alexander D. Montauban van Swijndregt
    Elisabeth M. Taal
    Tjitske S. R. van Engelen
    Jan M. Prins
    Shandra Bipat
    Patrick M. M. Bossuyt
    Jaap Stoker
    European Radiology Experimental, 8 (1)
  • [39] Influence of Ultra-Low-Dose and Iterative Reconstructions on the Visualization of Orbital Soft Tissues on Maxillofacial CT
    Widmann, G.
    Juranek, D.
    Waldenberger, F.
    Schullian, P.
    Dennhardt, A.
    Hoermann, R.
    Steurer, M.
    Gassner, E. -M
    Puelacher, W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (08) : 1630 - 1635
  • [40] Clinical Application of Iterative Reconstruction Technology in Ultra Low Dose Chest CT
    Wang, Qi
    Geng, Hai
    Bai, Huanguang
    Wang, Rongfang
    Dong, Guang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (08) : 1599 - 1602