Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor

被引:51
|
作者
Akter, Rashida [1 ]
Jeong, Bongjin [1 ]
Lee, Yong-Mi [1 ]
Choi, Jong-Soon [1 ,2 ]
Rahman, Md. Aminur [1 ]
机构
[1] Chungnam Natl Univ, Grad Sch Analyt Sci & Technol, GRAST, Daejeon 34134, South Korea
[2] Korea Basic Sci Inst, Div Life Sci, Daejeon 34133, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Impedimetric immunosensor; Dendrimer; 3; 5; '-Tetramethylbenzidine; Protein biomarkers; Cardiac troponin I; Human serum; ELECTROCHEMICAL IMMUNOSENSOR; GOLD NANOPARTICLES; CANCER BIOMARKERS; GRAPHENE; PROTEIN; BIOSENSOR; PLATFORM; ARRAY;
D O I
10.1016/j.bios.2017.01.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel highly sensitive dendrimer coupled impedimetric immunosensor was developed for the label-free and reagent-free detection of cardiac troponin I (TnI) in serum samples. The immunosensor probe was fabricated by covalently attaching carboxylic acid-functionalized third generation (G3) poly (amidoamine) (PAMAM) dendrimer (Den) on the 3, 3', 5, 5'-tetramethyl benzidine (TMB) modified 6-mercaptohexanoic acid (MHA) self-assembled monolayer (SAM) on a gold (Au) electrode. Monoclonal anti-TnI antibody was then covalently immobilized on the Den and TMB attached MHA SAM modified surface. TMB was used as an internal surface redox couple for generating signal which also allowed to avoid the use of an external one (i.e. ferricyanide couple) in solution during the impedance measurement for monitoring the antibody-antigen binding. On the other hand, Den was used as a signal enhancer by immobilizing more anti-body on the immunosensor probe. The immunosensor probe was characterized using X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques. The TnI detection in diluted serum was based on the measurement of charge transfer resistance (R-ct) of the electron transfer process of the surface -attached TMB before and after immunobinding. Under the optimized condition, the proposed immunosensor could detect human TnI in diluted serum samples as low as 11.7 fM with a wide linear dynamic range, good stability, and excellent specificity. The validity of the proposed method was tested in various TnI spiked human undiluted serum samples and was compared with the enzyme -linked immunosorbent assay (ELISA). The results suggested that the proposed immunosensor could be a useful tool for practical applications in clinical diagnosis.
引用
收藏
页码:637 / 643
页数:7
相关论文
共 50 条
  • [41] Label-Free Cancer Cell Detection with Impedimetric Transducers
    de la Rica, Roberto
    Thompson, Sebastian
    Baldi, Antonio
    Fernandez-Sanchez, Cesar
    Drain, Charles Michael
    Matsui, Hiroshi
    ANALYTICAL CHEMISTRY, 2009, 81 (24) : 10167 - 10171
  • [42] A new label-free impedimetric aptasensor for gluten detection
    Malvano, Francesca
    Albanese, Donatella
    Pilloton, Roberto
    Di Matteo, Marisa
    FOOD CONTROL, 2017, 79 : 200 - 206
  • [43] Label-free electrochemical aptasensor for femtomolar detection of 17β-estradiol
    Zhu, Bicheng
    Alsager, Omar A.
    Kumar, Shalen
    Hodgkiss, Justin M.
    Travas-Sejdic, Jadranka
    BIOSENSORS & BIOELECTRONICS, 2015, 70 : 398 - 403
  • [44] A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs)
    Tuteja, Satish K.
    Chen, Rui
    Kukkar, Manil
    Song, Chung Kil
    Mutreja, Ruchi
    Singh, Suman
    Paul, Ashok K.
    Lee, Haiwon
    Kim, Ki-Hyun
    Deep, Akash
    Suri, C. Raman
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 548 - 556
  • [45] Label-Free Electrochemical Immunosensor Based on a Functionalized Ionic Liquid and Helical Carbon Nanotubes for the Determination of Cardiac Troponin I
    Shen, Qihui
    Liu, Man
    Lu, Yang
    Zhang, Dawei
    Cheng, Zhenyu
    Liu, Yan
    Gao, Huajing
    Jin, Zhaohui
    ACS OMEGA, 2019, 4 (07): : 11888 - 11892
  • [46] Magnetic silica nanotube-assisted impedimetric immunosensor for the separation and label-free detection of Salmonella typhimurium
    Phuong Diem Nguyen
    Trong Binh Tran
    Dung Thi Xuan Nguyen
    Min, Junhong
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 197 : 314 - 320
  • [47] A nanoporous membrane-based impedimetric immunosensor for label-free detection of pathogenic bacteria in whole milk
    Joung, Cho-Kyung
    Kim, Han-Nah
    Lim, Min-Cheol
    Jeon, Tae-Joon
    Kim, Hae-Yeong
    Kim, Young-Rok
    BIOSENSORS & BIOELECTRONICS, 2013, 44 : 210 - 215
  • [48] Label-free impedimetric immunosensor for detection of the textile azo dye Disperse Red 1 in treated water
    Rocha, Carolina G.
    Ferreira, Antonio A. P.
    Yamanaka, Hideko
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 52 - 59
  • [49] Impedimetric Immunosensor Based on a Polypyrrole-Antibiotic Model Film for the Label-Free Picomolar Detection of Ciprofloxacin
    Giroud, Fabien
    Gorgy, Karine
    Gondran, Chantal
    Cosnier, Serge
    Pinacho, Daniel G.
    Marco, M. -Pilar
    Sanchez-Baeza, Francisco J.
    ANALYTICAL CHEMISTRY, 2009, 81 (20) : 8405 - 8409
  • [50] Label-Free Detection of Chondroitin Sulphate Proteoglycan 4 by a Polyaniline/Graphene Nanocomposite Functionalized Impedimetric Immunosensor
    Fu, JingJing
    Shi, ZhuanZhuan
    Li, Man
    Wang, Yangyang
    Yu, Ling
    JOURNAL OF NANOMATERIALS, 2016, 2016