Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor

被引:51
|
作者
Akter, Rashida [1 ]
Jeong, Bongjin [1 ]
Lee, Yong-Mi [1 ]
Choi, Jong-Soon [1 ,2 ]
Rahman, Md. Aminur [1 ]
机构
[1] Chungnam Natl Univ, Grad Sch Analyt Sci & Technol, GRAST, Daejeon 34134, South Korea
[2] Korea Basic Sci Inst, Div Life Sci, Daejeon 34133, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Impedimetric immunosensor; Dendrimer; 3; 5; '-Tetramethylbenzidine; Protein biomarkers; Cardiac troponin I; Human serum; ELECTROCHEMICAL IMMUNOSENSOR; GOLD NANOPARTICLES; CANCER BIOMARKERS; GRAPHENE; PROTEIN; BIOSENSOR; PLATFORM; ARRAY;
D O I
10.1016/j.bios.2017.01.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel highly sensitive dendrimer coupled impedimetric immunosensor was developed for the label-free and reagent-free detection of cardiac troponin I (TnI) in serum samples. The immunosensor probe was fabricated by covalently attaching carboxylic acid-functionalized third generation (G3) poly (amidoamine) (PAMAM) dendrimer (Den) on the 3, 3', 5, 5'-tetramethyl benzidine (TMB) modified 6-mercaptohexanoic acid (MHA) self-assembled monolayer (SAM) on a gold (Au) electrode. Monoclonal anti-TnI antibody was then covalently immobilized on the Den and TMB attached MHA SAM modified surface. TMB was used as an internal surface redox couple for generating signal which also allowed to avoid the use of an external one (i.e. ferricyanide couple) in solution during the impedance measurement for monitoring the antibody-antigen binding. On the other hand, Den was used as a signal enhancer by immobilizing more anti-body on the immunosensor probe. The immunosensor probe was characterized using X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques. The TnI detection in diluted serum was based on the measurement of charge transfer resistance (R-ct) of the electron transfer process of the surface -attached TMB before and after immunobinding. Under the optimized condition, the proposed immunosensor could detect human TnI in diluted serum samples as low as 11.7 fM with a wide linear dynamic range, good stability, and excellent specificity. The validity of the proposed method was tested in various TnI spiked human undiluted serum samples and was compared with the enzyme -linked immunosorbent assay (ELISA). The results suggested that the proposed immunosensor could be a useful tool for practical applications in clinical diagnosis.
引用
收藏
页码:637 / 643
页数:7
相关论文
共 50 条
  • [11] Label-free detection of cardiac troponin I with a photonic crystal biosensor
    Zhang, Bailin
    Morales, Andres W.
    Peterson, Ralph
    Tang, Liang
    Ye, Jing Yong
    BIOSENSORS & BIOELECTRONICS, 2014, 58 : 107 - 113
  • [12] Label-free immunosensor for cardiac troponin I detection based on aggregation-induced electrochemiluminescence of a distyrylarylene derivative
    Yan, Mengxia
    Feng, Sinuo
    Yu, Linying
    Xue, Yu
    Huang, Jianshe
    Yang, Xiurong
    BIOSENSORS & BIOELECTRONICS, 2021, 192
  • [13] A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I
    Li Wang
    Yufeng Han
    Hongchen Wang
    Yaojie Han
    Jinhua Liu
    Gang Lu
    Haidong Yu
    Journal of Semiconductors, 2021, 42 (09) : 57 - 64
  • [14] A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I
    Li Wang
    Yufeng Han
    Hongchen Wang
    Yaojie Han
    Jinhua Liu
    Gang Lu
    Haidong Yu
    Journal of Semiconductors, 2021, (09) : 57 - 64
  • [15] A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I
    Wang, Li
    Han, Yufeng
    Wang, Hongchen
    Han, Yaojie
    Liu, Jinhua
    Lu, Gang
    Yu, Haidong
    JOURNAL OF SEMICONDUCTORS, 2021, 42 (09)
  • [16] Enhancement of label-free biosensing of cardiac troponin I
    Christenson, Chase
    Baryeh, Kwaku
    Ahadian, Samad
    Nasiri, Rohollah
    Dokmeci, Mehmet R.
    Goudie, Marcus
    Khademhosseini, Ali
    Ye, Jing Yong
    LABEL-FREE BIOMEDICAL IMAGING AND SENSING (LBIS) 2020, 2020, 11251
  • [17] Label-free electrochemiluminescence immunosensor for cardiac troponin I using luminol functionalized gold nanoparticles as a sensing platform
    Li, Fang
    Yu, Yuqi
    Cui, Hua
    Yang, Di
    Bian, Zhiping
    ANALYST, 2013, 138 (06) : 1844 - 1850
  • [18] Detecting penicillin G in milk with impedimetric label-free immunosensor
    Thavarungkul, Panote
    Dawan, Supapom
    Kanatharana, Proespichaya
    Asawatreratanakul, Punnee
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (05): : 688 - 694
  • [19] Gold nanoparticles mediated label-free capacitance detection of cardiac troponin I
    Bhalla, Vijayender
    Carrara, Sandro
    Sharma, Priyanka
    Nangia, Yogesh
    Suri, C. Raman
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 761 - 768
  • [20] Label-free detection of bisphenol A using a potentiometric immunosensor
    Piao, Ming-Hua
    Noh, Hui-Bog
    Rahman, Md Aminur
    Won, Mi-Sook
    Shim, Yoon-Bo
    ELECTROANALYSIS, 2008, 20 (01) : 30 - 37