A nanoporous membrane-based impedimetric immunosensor for label-free detection of pathogenic bacteria in whole milk

被引:95
|
作者
Joung, Cho-Kyung [1 ,2 ]
Kim, Han-Nah [1 ,2 ]
Lim, Min-Cheol [1 ,2 ]
Jeon, Tae-Joon [3 ,4 ]
Kim, Hae-Yeong [1 ,2 ]
Kim, Young-Rok [1 ,2 ]
机构
[1] Kyung Hee Univ, Coll Life Sci, Inst Life Sci & Resources, Yongin 446701, South Korea
[2] Kyung Hee Univ, Coll Life Sci, Dept Food Sci & Biotechnol, Yongin 446701, South Korea
[3] Inha Univ, Dept Biol Engn, Inchon 402751, South Korea
[4] Inha Univ, Biohybrid Syst Res Ctr, Inchon 402751, South Korea
来源
关键词
Impedimetric immunosensor; Nanoporous membrane; Label-free detection; Pathogenic bacteria; Food; Hyaluronic acid; ESCHERICHIA-COLI O157-H7; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; HEMOLYTIC-UREMIC SYNDROME; LISTERIA-MONOCYTOGENES; SENSITIVE DETECTION; ANODIZED ALUMINUM; FOOD SAMPLES; PCR; MICROFLUIDICS; ANTIBODIES;
D O I
10.1016/j.bios.2013.01.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We introduce a nanoporous membrane based impedimetric immunosensor for the label-free detection of bacterial pathogens in whole milk. A simple and rapid method to modify a commercially available alumina nanoporous membrane with hyaluronic acid (HA) effectively reduced the non-specific binding of biomolecules and other cells, and permitted successful immobilization of antibodies. Escherichia coli O157:H7, one of the most harmful food-borne pathogenic bacteria, was tested as a model pathogen in this study. The ionic impedance of electrolytes through nanopores, due to antibody-pathogen interactions, was monitored by impedance spectra and analyzed by normalized impedance change (NIC). The regression equation for the NIC at 1 kHz versus concentration of E. coli O157:H7 (10-10(5) cfu/ml) was obtained, and the detection limit found to be as low as 10 cfu/ml. In addition, the proposed immunosensor was successfully used for the detection of E. coli O157:H7 in whole milk samples with the detection limit as low as 83.7 cfu/ml with 95% probability. The specificity of the immunosensor was also demonstrated using non-target bacteria, including Staphylococcus aureus, Bacillus cereus, and non pathogenic E. coli DH5 alpha. This study shows that a HA-functionalized nanoporous membrane-based impedimetric sensor is capable of detecting pathogenic bacteria in whole milk without any pretreatment. This is a significant step for evaluating the safety of food and environmental samples and other medical diagnostics. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
  • [1] An impedimetric immunosensor for the label-free detection of bisphenol A
    Rahman, Md. Aminur
    Shiddiky, Muhammad J. A.
    Park, Jang-Su
    Shim, Yoon-Bo
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2464 - 2470
  • [2] Label-free impedimetric immunosensor for sensitive detection of atrazine
    Ionescu, Rodica E.
    Gondran, Chantal
    Bouffier, Laurent
    Jaffrezic-Renault, Nicole
    Martelet, Claude
    Cosnier, Serge
    ELECTROCHIMICA ACTA, 2010, 55 (21) : 6228 - 6232
  • [3] Label-free impedimetric immunosensor for sensitive detection of ochratoxin A
    Radi, Abd-Elgawad
    Munoz-Berbel, Xavier
    Lates, Vasilica
    Marty, Jean-Louis
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 1888 - 1892
  • [4] Detecting penicillin G in milk with impedimetric label-free immunosensor
    Thavarungkul, Panote
    Dawan, Supapom
    Kanatharana, Proespichaya
    Asawatreratanakul, Punnee
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (05): : 688 - 694
  • [5] A label-free silver wire based impedimetric immunosensor for detection of aflatoxin M1 in milk
    Bacher, Gautam
    Pal, Souvik
    Kanungo, Lizy
    Bhand, Sunil
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 223 - 230
  • [6] Label-free voltammetric immunosensor using a nanoporous membrane based platform
    de la Escosura-Muniz, Alfredo
    Merkoci, Arben
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (06) : 859 - 863
  • [7] Label-free impedimetric immunosensor for sensitive detection of fenvalerate in tea
    Wang, Meirong
    Kang, Huimin
    Xu, Dan
    Wang, Chengyin
    Liu, Shuzhao
    Hu, Xiaoya
    FOOD CHEMISTRY, 2013, 141 (01) : 84 - 90
  • [8] Label-free ITO-based immunosensor for the detection of very low concentrations of pathogenic bacteria
    Barreiros dos Santos, M.
    Azevedo, S.
    Agusil, J. P.
    Prieto-Simon, B.
    Sporer, C.
    Torrents, E.
    Juarez, A.
    Teixeira, V.
    Samitier, J.
    BIOELECTROCHEMISTRY, 2015, 101 : 146 - 152
  • [9] Electrochemical nanoporous alumina membrane-based label-free DNA biosensor for the detection of Legionella sp
    Rai, Varun
    Deng, Jiajia
    Toh, Chee-Seng
    TALANTA, 2012, 98 : 112 - 117
  • [10] Development of a label-free impedimetric immunosensor for the detection of respiratory syncytial virus
    Stefanne e Silva, Tallita
    Oliveira e Freitas, Guilherme Ramos
    Ferreira, Lucas Franco
    Franco, Diego Leoni
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024, 28 (11) : 4015 - 4027