The effects of radiation on gallium arsenide radiation detectors

被引:16
|
作者
Bates, RL [1 ]
DaVia, C [1 ]
DAuria, S [1 ]
OShea, V [1 ]
Raine, C [1 ]
Smith, KM [1 ]
机构
[1] UNIV UDINE,DIPARTIMENTO FIS,I-33100 UDINE,ITALY
关键词
D O I
10.1016/S0168-9002(97)00628-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Semi-insulating, undoped, Liquid Encapsulated Czochralski (SI-U LEG) GaAs detectors have been irradiated with 1 MeV neutrons, 24 GeV/c protons, and 300 MeV/c pions. The maximum fluences used were 6 x10(14), 3 x10(14), and 1.8 x10(14) particles/cm(2), respectively. For all three types of irradiation, the charge collection efficiencies (cce) of the detector are reduced due to the reduction in the electron and hole mean free paths. Pion and proton irradiations produce a greater reduction in cce than neutron irradiation, with the pions having the greatest effect. The effect of annealing the detectors at room temperature, at 200 degrees C and at 450 degrees C with a flash lamp have been shown to reduce the leakage current and increase the cce of the irradiated detectors. The flash-lamp anneal produced the greatest increase in the cce from 26% to 70% by increasing the mean free path of the electrons. Two indium-doped samples were irradiated with 24 GeV/e protons and demonstrated no improvement over SI-U GaAs with respect to post-irradiation cce.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [21] POLARIZATION OF RADIATION FROM GALLIUM ARSENIDE DIODES
    ALYAMOVS.VN
    BAGAEV, VS
    BEROZASH.YN
    VUL, BM
    SOVIET PHYSICS SOLID STATE,USSR, 1966, 8 (04): : 871 - +
  • [22] APPLICATION OF GALLIUM ARSENIDE LIGHT SOURCES FOR CALIBRATING SYSTEMS USING SEMICONDUCTOR DETECTORS OF NUCLEAR RADIATION
    NAUMOV, VI
    OMELYANE.MN
    RYKALIN, VI
    TITOVA, VF
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (04): : 833 - &
  • [23] CADMIUM ARSENIDE CRYSTALS AS NERNST RADIATION DETECTORS
    LOVETT, DR
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1973, 17 (02): : K123 - K127
  • [24] Gallium arsenide pixel detectors
    Univ of Glasgow, Glasgow, United Kingdom
    Nucl Instrum Methods Phys Res Sect A, 1 (6-11):
  • [25] Gallium arsenide pixel detectors
    Bates, R
    Campbell, M
    Cantatore, E
    D'Auria, S
    DaVia, C
    del Papa, C
    Heijne, EM
    Middelkamp, P
    O'Shea, V
    Raine, C
    Ropotar, I
    Scharfetter, L
    Smith, K
    Snoeys, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (01): : 6 - 11
  • [26] New effects in gallium arsenide implanted with bipurity ions and subjected to radiation annealing
    Ardyshev, MV
    Korus 2004, Vol 2, Proceedings, 2004, : 184 - 188
  • [27] Gallium arsenide for vertex detectors
    DAuria, S
    Bates, R
    DaVia, C
    delPapa, C
    Gowdy, S
    OShea, V
    Raine, C
    Smith, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 386 (01): : 177 - 185
  • [28] Radiation hard microstrip detector based on gallium arsenide
    Inst for High Energy Physics, Protvino, Russia
    Nucl Instrum Methods Phys Res Sect A, 3 (406-408):
  • [29] STRUCTURE OF THE INTRINSIC RECOMBINATION RADIATION SPECTRUM OF GALLIUM ARSENIDE
    NASLEDOV, DN
    ROGACHEV, AA
    RYVKIN, SM
    KHARTSIEV, VE
    TSARENKOV, BV
    SOVIET PHYSICS-SOLID STATE, 1963, 4 (11): : 2449 - 2451
  • [30] Gamma- radiation damage in expitaxial gallium arsenide
    BREHM GE
    PEARSON GL
    1600, (43):