The effects of radiation on gallium arsenide radiation detectors

被引:16
|
作者
Bates, RL [1 ]
DaVia, C [1 ]
DAuria, S [1 ]
OShea, V [1 ]
Raine, C [1 ]
Smith, KM [1 ]
机构
[1] UNIV UDINE,DIPARTIMENTO FIS,I-33100 UDINE,ITALY
关键词
D O I
10.1016/S0168-9002(97)00628-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Semi-insulating, undoped, Liquid Encapsulated Czochralski (SI-U LEG) GaAs detectors have been irradiated with 1 MeV neutrons, 24 GeV/c protons, and 300 MeV/c pions. The maximum fluences used were 6 x10(14), 3 x10(14), and 1.8 x10(14) particles/cm(2), respectively. For all three types of irradiation, the charge collection efficiencies (cce) of the detector are reduced due to the reduction in the electron and hole mean free paths. Pion and proton irradiations produce a greater reduction in cce than neutron irradiation, with the pions having the greatest effect. The effect of annealing the detectors at room temperature, at 200 degrees C and at 450 degrees C with a flash lamp have been shown to reduce the leakage current and increase the cce of the irradiated detectors. The flash-lamp anneal produced the greatest increase in the cce from 26% to 70% by increasing the mean free path of the electrons. Two indium-doped samples were irradiated with 24 GeV/e protons and demonstrated no improvement over SI-U GaAs with respect to post-irradiation cce.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [31] INFLUENCE OF IMPURITIES ON RECOMBINATION RADIATION SPECTRA OF GALLIUM ARSENIDE
    IMENKOV, AN
    KOGAN, LM
    KOZLOV, MM
    MESKIN, SS
    NASLEDOV, DN
    TSARENKO.BV
    SOVIET PHYSICS SOLID STATE,USSR, 1966, 7 (10): : 2519 - +
  • [32] Radiation hard microstrip detector based on gallium arsenide
    Chmill, VB
    Chuntonov, AV
    Smoll, AV
    Vorobiev, AP
    Khludkov, SS
    Koretski, AA
    Potapov, AI
    Tolbanov, OP
    Smith, KM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (03): : 406 - 408
  • [33] Epitaxial gallium arsenide for nuclear radiation detector applications
    Lauter, J
    Bauser, E
    Forster, A
    Hardtdegen, H
    Hollfelder, M
    Luth, H
    Protic, D
    Zehender, S
    NUCLEAR PHYSICS B, 1995, : 381 - 385
  • [34] INSTABILITY OF RECOMBINATION RADIATION IN SEMIINSULATING GALLIUM-ARSENIDE
    PEKA, GP
    KARKHANIN, YI
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1972, 6 (04): : 639 - +
  • [35] RADIATION DAMAGE IN COPPER-DOPED GALLIUM ARSENIDE
    PAPEIKO, AS
    RADOVSKI.EE
    STELMAKH, VF
    TKACHEV, VD
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1970, 4 (01): : 112 - &
  • [36] INDUCED RADIATION IN GALLIUM ARSENIDE WHEN OPTICALLY EXCITED
    BASOV, NG
    GRASYUK, AZ
    KATULIN, VA
    DOKLADY AKADEMII NAUK SSSR, 1965, 161 (06): : 1306 - &
  • [37] Proton induced bulk damage effects in gallium arsenide detectors
    Nava, F
    Vanni, P
    Cavallini, A
    Castaldini, A
    Canali, C
    Quaranta, AA
    Lanzieri, C
    NUCLEAR PHYSICS B, 1998, : 432 - 437
  • [38] RADIATION EFFECTS IN GALLIUM-ARSENIDE INDIUM OXIDE AND SILICON INDIUM OXIDE HETEROJUNCTIONS
    KAR, S
    RAO, KV
    PANDEY, A
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1985, 132 (06) : C219 - C220
  • [39] EFFECTS OF RADIATION-INDUCED DISPLACEMENT DAMAGE ON IMPURITY CONDUCTION IN GALLIUM-ARSENIDE
    BERG, NJ
    LIEBERMAN, AG
    JOURNAL OF APPLIED PHYSICS, 1975, 46 (08) : 3475 - 3482
  • [40] Use of epitaxial gallium arsenide in detectors
    V. M. Zaletin
    Yu. V. Tuzov
    V. F. Dvoryankin
    A. A. Sokolovskii
    Atomic Energy, 2007, 103 : 901 - 905