Comparison of gamma ( Anger) camera systems in terms of detective quantum efficiency using Monte Carlo simulation

被引:1
|
作者
Eriksson, Ida [1 ,2 ]
Starck, Sven-Ake [4 ,5 ]
Bath, Magnus [2 ,3 ]
机构
[1] Karlstad Hosp, Dept Med Phys, SE-65185 Karlstad, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Biomed Engn & Med Phys, Gothenburg, Sweden
[4] Sch Hlth Sci, Dept Nat Sci & Biomed, Jonkoping, Sweden
[5] Cty Hosp Ryhov, Dept Oncol, Jonkoping, Sweden
关键词
collimator; detective quantum efficiency; gamma camera; Monte Carlo technique; DIGITAL CHEST RADIOGRAPHY; NODULE DETECTION; IMAGING PROPERTIES; PERFORMANCE; NOISE; COLLIMATOR; SPECT; OPTIMIZATION; ARCHITECTURE; GENERATIONS;
D O I
10.1097/MNM.0000000000000053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimThe aim of the present study was to perform an extensive evaluation of available gamma camera systems in terms of their detective quantum efficiency (DQE) and determine their dependency on relevant parameters such as collimator type, imaging depth, and energy window using the Monte Carlo technique.Materials and methodsThe modulation transfer function was determined from a simulated Tc-99m point source and was combined with the system sensitivity and photon yield to obtain the DQE of the system. The simulations were performed for different imaging depths in a water phantom for 13 gamma camera systems from four manufacturers.ResultsExcept at very low spatial frequencies, the highest DQE values were found with a lower energy window threshold of around 130 keV for all systems. The height and shape of the DQE curves were affected by the collimator design and the intrinsic properties of the gamma camera systems. High-sensitivity collimators gave the highest DQE at low spatial frequencies, whereas the high-resolution and ultrahigh-resolution collimators showed higher DQE values at higher frequencies. The intrinsic resolution of the system mainly affected the DQE curve at superficial depths.ConclusionThe results indicate that the manufacturers have succeeded differently in their attempts to design a system constituting an optimal compromise between sensitivity and spatial resolution.
引用
收藏
页码:405 / 415
页数:11
相关论文
共 50 条
  • [31] A Monte Carlo simulation of coincidence detection and imaging of gamma-ray cascades with a scintillation camera
    Pahlka, R. Benton
    Kappadath, S. Cheenu
    Mawlawi, Osama R.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05):
  • [32] Approximation of hexagonal holes by square holes in Monte Carlo simulation of gamma-camera collimation
    de Vries, DJ
    Moore, SC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2186 - 2195
  • [34] MONTE-CARLO SIMULATION OF QUANTUM SPIN SYSTEMS .1.
    SUZUKI, M
    MIYASHITA, S
    KURODA, A
    PROGRESS OF THEORETICAL PHYSICS, 1977, 58 (05): : 1377 - 1387
  • [35] Monte Carlo simulation of the topological quantities in fractional quantum Hall systems
    Yang, Yi
    Hu, Zi-Xiang
    PHYSICAL REVIEW B, 2023, 107 (11)
  • [36] EVALUATION OF GAMMA RADIATION DOSES IN SOIL USING THE MONTE CARLO SIMULATION
    Ionescu, Clement
    Sbirna, Liana Simona
    Mateescu, Monica Daniela
    Moldovan, Clementina Sabina
    Sbirna, Sebastian
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2012, 11 (07): : 1355 - 1360
  • [37] Analysis of the Gamma spectrum using Monte Carlo simulation and Gaussian reconstruction
    Ye E.
    Chen F.
    Lai Y.
    Liu J.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (12): : 2232 - 2238
  • [38] Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector
    Yalcin, S.
    Gurler, O.
    Gundogdu, O.
    Kaynak, G.
    RADIATION MEASUREMENTS, 2009, 44 (01) : 80 - 85
  • [39] Quantum Monte Carlo simulation for the conductance of one-dimensional quantum spin systems
    Louis, K
    Gros, C
    PHYSICAL REVIEW B, 2003, 68 (18)
  • [40] A comparison of Logit and Probit models using Monte Carlo simulation
    Ma, Jun
    Li, Congying
    2021 PROCEEDINGS OF THE 40TH CHINESE CONTROL CONFERENCE (CCC), 2021, : 8963 - 8967