Comparison of gamma ( Anger) camera systems in terms of detective quantum efficiency using Monte Carlo simulation

被引:1
|
作者
Eriksson, Ida [1 ,2 ]
Starck, Sven-Ake [4 ,5 ]
Bath, Magnus [2 ,3 ]
机构
[1] Karlstad Hosp, Dept Med Phys, SE-65185 Karlstad, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Biomed Engn & Med Phys, Gothenburg, Sweden
[4] Sch Hlth Sci, Dept Nat Sci & Biomed, Jonkoping, Sweden
[5] Cty Hosp Ryhov, Dept Oncol, Jonkoping, Sweden
关键词
collimator; detective quantum efficiency; gamma camera; Monte Carlo technique; DIGITAL CHEST RADIOGRAPHY; NODULE DETECTION; IMAGING PROPERTIES; PERFORMANCE; NOISE; COLLIMATOR; SPECT; OPTIMIZATION; ARCHITECTURE; GENERATIONS;
D O I
10.1097/MNM.0000000000000053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimThe aim of the present study was to perform an extensive evaluation of available gamma camera systems in terms of their detective quantum efficiency (DQE) and determine their dependency on relevant parameters such as collimator type, imaging depth, and energy window using the Monte Carlo technique.Materials and methodsThe modulation transfer function was determined from a simulated Tc-99m point source and was combined with the system sensitivity and photon yield to obtain the DQE of the system. The simulations were performed for different imaging depths in a water phantom for 13 gamma camera systems from four manufacturers.ResultsExcept at very low spatial frequencies, the highest DQE values were found with a lower energy window threshold of around 130 keV for all systems. The height and shape of the DQE curves were affected by the collimator design and the intrinsic properties of the gamma camera systems. High-sensitivity collimators gave the highest DQE at low spatial frequencies, whereas the high-resolution and ultrahigh-resolution collimators showed higher DQE values at higher frequencies. The intrinsic resolution of the system mainly affected the DQE curve at superficial depths.ConclusionThe results indicate that the manufacturers have succeeded differently in their attempts to design a system constituting an optimal compromise between sensitivity and spatial resolution.
引用
收藏
页码:405 / 415
页数:11
相关论文
共 50 条
  • [21] On the Monte Carlo simulation of HPGe gamma-spectrometry systems
    Sima, Octavian
    Arnold, Dirk
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (05) : 701 - 705
  • [22] Monte Carlo simulation of HPGe gamma-spectrometry systems
    Hou, Dongjie
    Guo, Siming
    Huang, Jianwei
    Wu, Chong
    Wu, Jinjie
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (23): : 9064 - 9068
  • [23] Monte-Carlo Simulation of the Detective Quantum Efficiency of Cadmium Telluride X-Ray Detectors for Photon-Counting Mammography
    Day, J.
    Tanguay, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [24] QUANTUM MONTE-CARLO SIMULATION METHOD FOR SPIN SYSTEMS
    SANDVIK, AW
    KURKIJARVI, J
    PHYSICAL REVIEW B, 1991, 43 (07): : 5950 - 5961
  • [25] Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study
    Lee, Youngjin
    Park, Chanrok
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (12) : 4652 - 4659
  • [26] Monte Carlo simulation of a CsI(Tl) gamma camera dedicated to small animal imaging using GATE.
    Lazaro, D
    Buvat, I
    Donnarieix, D
    Loudos, G
    Giokaris, N
    Strul, D
    Santin, G
    Maigne, L
    Spanoudaki, V
    Styliaris, S
    Staelens, S
    Breton, V
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 288P - 288P
  • [27] Monte Carlo simulation for Gamma Knife radiosurgery using the Grid
    Ganesan, Vasu
    Mehrem, Rami
    Fenner, John
    Walton, Lee
    RADIOSURGERY, VOL 6, 2006, 6 : 26 - 35
  • [28] COMPARISON OF RATIO ESTIMATORS USING MONTE CARLO SIMULATION
    Reddy, M. Krishna
    Rao, K. Ranga
    Boiroju, Naveen Kumar
    INTERNATIONAL JOURNAL OF AGRICULTURAL AND STATISTICAL SCIENCES, 2010, 6 (02): : 517 - 527
  • [29] A small gamma camera combined with a uniformly redundant array (URA) collimator: the performance evaluation using detective quantum efficiency (DQE)
    Jeon, Hosang
    Kim, Hyunduk
    Lee, Chae Hun
    Chang, Sungho
    Rahman, Mohammad S.
    Cho, Gyuseong
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1237 - 1240
  • [30] Semiclassical and Quantum Transport in CNTFETs Using Monte Carlo Simulation
    Huu-Nha Nguyen
    Querlioz, Damien
    Galdin-Retailleau, Sylvie
    Dollfus, Philippe
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2011, 58 (03) : 798 - 804