Monte Carlo simulation of a CsI(Tl) gamma camera dedicated to small animal imaging using GATE.

被引:0
|
作者
Lazaro, D
Buvat, I
Donnarieix, D
Loudos, G
Giokaris, N
Strul, D
Santin, G
Maigne, L
Spanoudaki, V
Styliaris, S
Staelens, S
Breton, V
机构
[1] CNRS IN2P3, Phys Corpusculaire Lab, Clermont Ferrand, France
[2] CHU Pitie Salpetriere, Paris, France
[3] Ctr Jean Perrin, Dept Curietherapie Radiotherapie, Clermont Ferrand, France
[4] Univ Athens, Ins Accelerat Syst & Application of Athens, GR-10679 Athens, Greece
[5] Univ Lausanne, Inst High Energy Phys, CH-1015 Lausanne, Switzerland
[6] ESA, Estec, Noordwijk, Netherlands
[7] State Univ Ghent, ELIS Medisip, Ghent, Belgium
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
1032
引用
收藏
页码:288P / 288P
页数:1
相关论文
共 50 条
  • [1] Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging
    Lazaro, D
    Buvat, I
    Loudos, G
    Strul, D
    Santin, G
    Giokaris, N
    Donnarieix, D
    Maigne, L
    Spanoudaki, V
    Styliaris, S
    Staelens, S
    Breton, V
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02): : 271 - 285
  • [2] Development of GATE Monte Carlo simulation for a CsI pixelated gamma camera dedicated to high resolution animal SPECT
    Payvand Taherparvar
    Alireza Sadremomtaz
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 31 - 39
  • [3] Development of GATE Monte Carlo simulation for a CsI pixelated gamma camera dedicated to high resolution animal SPECT
    Taherparvar, Payvand
    Sadremomtaz, Alireza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (01) : 31 - 39
  • [5] Monte-Carlo simulation of pinhole collimator of a small field of view gamma camera for small animal imaging
    Zhu Jie
    Ma Wenyan
    Zhu Yufeng
    Ma Hongguang
    Wu Yuelei
    Hu Huasi
    Zhang Boping
    Huo Yonggang
    Liu Silu
    Han Bin
    Wang Zhaomin
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (01) : 37 - 41
  • [6] Validation and optimization studies of small animal SPECT using GATE Monte Carlo simulation
    Sadremomtaz, Alireza
    Telikani, Zeinab
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 915 : 94 - 101
  • [7] Development of GATE Monte Carlo simulation for a dual-head gamma camera
    Momennezhad, Mehdi
    Sadeghi, Ramin
    Nasseri, Shahrokh
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2012, 5 (02) : 222 - 228
  • [8] Development of GATE Monte Carlo simulation for a dual-head gamma camera
    Mehdi Momennezhad
    Ramin Sadeghi
    Shahrokh Nasseri
    Radiological Physics and Technology, 2012, 5 (2) : 222 - 228
  • [9] Simulation of the basic features of the GE Millennium MG SPET gamma camera using GATE Monte Carlo simulation
    Vieira, L. C. C. O.
    Costa, D. C.
    Almeida, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S490 - S490
  • [10] Comparison of a GATE Monte Carlo Simulation Predictions to the Performance of a High-Resolution LYSO Based Dedicated Animal PET Camera
    Baghaei, Hossain
    Zhang, Yuxuan
    Li, Hongdi
    Ramirez, Rocio A.
    Liu, Shitao
    Wang, Chao
    An, Shaohui
    Wong, Wai-Hoi
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2388 - 2392