A Monte Carlo simulation of coincidence detection and imaging of gamma-ray cascades with a scintillation camera

被引:4
|
作者
Pahlka, R. Benton [1 ]
Kappadath, S. Cheenu [1 ]
Mawlawi, Osama R. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, UNIT 1472, POB 301402, Houston, TX 77230 USA
来源
关键词
gamma-ray cascades; coincidence detection; gamma camera;
D O I
10.1088/2057-1976/aad572
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Several radionuclei used in nuclear medicine decay through the emission of cascaded gamma-rays. These successively-emitted gamma-rays could potentially be detected in coincidence and then be used to create coincident event-based images. While several groups have considered various ways to leverage the gamma-ray cascade to produce images, the concept of producing images using cascaded gamma rays in coincidence with a dual-head gamma camera has not been previously explored in detail. Given that current dual-head gamma cameras cannot be configured in coincidence mode, the purpose of this work was to explore this concept with In-111 using a Monte Carlo simulation. First, GEANT4 was used to model a dual-head gamma camera and to simulate the decay of the nucleus. The model was then validated using planar data from a physical scanner. The validated model was then used to simulate a point source of In-111 located at the camera isocenter to evaluate the true coincidence efficiency with the detectors oriented at 90 degrees. The noise-equivalent-count-rate (NECR) as a function of timing window resolution was computed for different source activities. A simple reconstruction algorithm was then used to produce coincidence-based images from sources in various configurations. The coincident gamma-ray detection efficiency for a single point source in air with the detector heads oriented at 90 degrees was found to be 6 x 10(-8), independent of the source-to-detector distance. The time window resolution for the maximum NECR ranged between 200 and 500 ns, dependent on source activity. The algorithm could produce images over a range of timing window resolutions, with varying levels of reconstruction artifacts. Images produced from a small acrylic phantom showed that scattered events produced small degradations in resolution and contrast-to-noise ratios. This work described the conditions under which images based on coincident events from In-111 could be created using a dual head gamma camera, assuming appropriate electronics modifications.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] MONTE-CARLO SIMULATION OF GAMMA-RAY DETECTORS USING SCINTILLATION FIBERS
    CHANEY, RC
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 18 - 26
  • [2] Monte Carlo simulation of the nonlinear full peak energy responses for gamma-ray scintillation detectors
    Peeples, Johanna L.
    Gardner, Robin P.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1058 - 1062
  • [3] A benchmark for Monte Carlo simulation in gamma-ray spectrometry
    Lepy, M. C.
    Thiam, C.
    Anagnostakis, M.
    Galea, R.
    Gurau, D.
    Hurtado, S.
    Karfopoulos, K.
    Liang, J.
    Liu, H.
    Luca, A.
    Mitsios, I
    Potiriadis, C.
    Savva, M., I
    Thanh, T. T.
    Thomas, V
    Townson, R. W.
    Vasilopoulou, T.
    Zhang, M.
    APPLIED RADIATION AND ISOTOPES, 2019, 154
  • [4] Gamma-ray interaction in Ge: A Monte Carlo simulation
    Gao, F.
    Campbell, L. W.
    Devanathan, R.
    Xie, Y. L.
    Zhang, Y.
    Peurrung, A. J.
    Weber, W. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 255 (01): : 286 - 290
  • [5] GAMMA-RAY AND POSITRON SCINTILLATION CAMERA
    ANGER, HO
    NUCLEONICS, 1963, 21 (10): : 56 - &
  • [6] Monte Carlo Simulation of Intrinsic Count Rate Performance for Scintillation Gamma Camera
    Mowlavi, A. A.
    de Denaro, M.
    Fornasier, M. R.
    Binesh, A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 209 - 211
  • [7] DESIGN AND SIMULATION OF A GAMMA-RAY CAMERA FOR PET WITH A CONTINUOUS SCINTILLATION CRYSTAL
    Boghrati, Behzad
    Zarandi, Ali Moussavi
    Ghergherehchi, Mitra
    Chai, Jong Seo
    NUCLEAR TECHNOLOGY, 2012, 178 (03) : 324 - 334
  • [8] Gamma-ray imaging with a large micro-TPC and a scintillation camera
    Hattori, K.
    Kabuki, S.
    Kubo, H.
    Kurosawa, S.
    Miuchi, K.
    Nagayoshi, T.
    Nishimura, H.
    Okada, Y.
    Orito, R.
    Sekiya, H.
    Takada, A.
    Takeda, A.
    Tanimori, T.
    Ueno, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 517 - 521
  • [9] AGILESim: Monte Carlo Simulation of the AGILE Gamma-Ray Telescope
    Fioretti, V
    Bulgarelli, A.
    Tavani, M.
    Sabatini, S.
    Aboudan, A.
    Argan, A.
    Cattaneo, P. W.
    Chen, A. W.
    Donnarumma, I
    Longo, F.
    Galli, M.
    Giuliani, A.
    Marisaldi, M.
    Parmiggiani, N.
    Rappoldi, A.
    ASTROPHYSICAL JOURNAL, 2020, 896 (01):
  • [10] MONTE-CARLO SIMULATION OF ASTROPHYSICAL GAMMA-RAY PRODUCTION
    MORRIS, DJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (04): : 625 - 625