Accuracy of different definitive impression techniques with the all-on-4 protocol

被引:8
|
作者
Ozan, Oguz [1 ]
Hamis, Oguz [2 ]
机构
[1] Near East Univ, Fac Dent, Dept Prosthodont, Nicosia, Mersin, Turkey
[2] Near East Univ, Fac Dent, Nicosia, Mersin, Turkey
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 121卷 / 06期
关键词
IMPLANT ANGULATION; CLINICAL ACCURACY;
D O I
10.1016/j.prosdent.2018.08.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. A nonpassive fit of implant-supported restorations can jeopardize the biological and mechanical success of the treatment. Data regarding the fit of different impression techniques for the all-on-4 protocol are limited. Purpose. The purpose of this in vitro study was to digitally evaluate 4 different impression techniques used with the all-on-4 protocol, with distal multiunit analogs positioned in 4 different angulations. Material and methods. Four maxillary definitive cast models with 4 multiunit analogs (T0 32202; NucleOSS) were fabricated according to the all-on-4 treatment protocol. In the anterior region, the analogs were positioned in a parallel direction, whereas in the posterior region, they were positioned in different angulations (0, 10, 20, and 30 degrees). One hundred and sixty models were obtained by using 4 different impression techniques (closed tray without plastic cap, closed tray with plastic cap, splinted open tray, sectioned resplinted open tray) (n=10) and polyvinyl siloxane impression material. Definitive casts and definitive duplicate casts were scanned using a modified laser scanner (Activity 880; Smart Optics Sensortechnik GmbH), and data were transferred to a software program (VRMesh Studio; Virtual Grid Inc). The definitive casts and definitive duplicate cast scans were digitally aligned. Angular and linear deviations in all axes (x, y, and z) of the analogs between definitive and duplicate casts were calculated and subjected to statistical analyses (alpha=.05). Results. Mean angular deviations were in the range of 0.03 to 0.16 degrees, and linear deviations were in the range of 0.10 to 0.75 mm. The increased angulation between impression copings caused higher linear and angular deviations when closed-tray impression techniques were used (P<.05). Conclusions. Reduced linear and angular displacements were obtained from the open-tray impression techniques compared with the closed-tray impression techniques in the angulated groups. Angular and linear deviations increased with the increase in the angulation of the posterior analog.
引用
收藏
页码:941 / 948
页数:8
相关论文
共 50 条
  • [31] Accuracy of 2 impression techniques for ITI implants
    Akça, K
    Çehreli, MC
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (04) : 517 - 523
  • [32] Effect of modified tray design on accuracy of different impression techniques for parallel and divergent implants
    Dang, Liem
    Woliansky, Matthew
    Palamara, Joseph
    Abduo, Jaafar
    [J]. JOURNAL OF ORAL SCIENCE, 2020, 62 (04) : 439 - 443
  • [33] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    [J]. JOURNAL OF DENTISTRY, 2022, 126
  • [35] Accuracy of digital and conventional impression techniques and workflow
    Seelbach, Paul
    Brueckel, Cora
    Woestmann, Bernd
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1759 - 1764
  • [36] Accuracy of digital and conventional impression techniques and workflow
    Paul Seelbach
    Cora Brueckel
    Bernd Wöstmann
    [J]. Clinical Oral Investigations, 2013, 17 : 1759 - 1764
  • [37] TREATMENT OF COMPLETE EDENTULISM USING THE ALL-ON-4 SYSTEM
    Diaconu-popa, Diana
    Vitalariu, Anca
    Aungurencei, Andra
    Cioloca, Catalina H. O. L. B. A. N.
    Tatarciuc, Monica
    [J]. INTERNATIONAL JOURNAL OF MEDICAL DENTISTRY, 2021, 25 (04) : 566 - 569
  • [38] All-on-4无牙颌种植即刻修复技术
    孙超
    李英
    [J]. 全科口腔医学电子杂志, 2015, 2 (10) : 7 - 9
  • [39] Biomechanical analysis of stress around the tilted implants with different cantilever lengths in all-on-4 concept
    Wang, Qi
    Zhang, Zhen-zhen
    Bai, Shi-zhu
    Zhang, Shao-feng
    [J]. BMC ORAL HEALTH, 2022, 22 (01)
  • [40] Evaluation of the surgical and prosthetic success of All-on-4 restorations: a retrospective cohort study of provisional vs. definitive immediate restorations
    Korsch, Michael
    Walther, Winfried
    Hannig, Matthias
    Bartols, Andreas
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)