Evaluation of Compton gamma camera prototype based on pixelated CdTe detectors

被引:5
|
作者
Calderon, Y. [1 ]
Chmeissani, M. [1 ]
Kolstein, M. [1 ]
De Lorenzo, G. [1 ]
机构
[1] UAB, IFAE, E-08193 Bellaterra, Barcelona, Spain
来源
基金
欧洲研究理事会;
关键词
Compton imaging; Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); Solid state detectors;
D O I
10.1088/1748-0221/9/06/C06003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A proposed Compton camera prototype based on pixelated CdTe is simulated and evaluated in order to establish its feasibility and expected performance in real laboratory tests. The system is based on module units containing a 2 x 4 array of square CdTe detectors of 10 x 10 mm(2) area and 2 mm thickness. The detectors are pixelated and stacked forming a 3D detector with voxel sizes of 2 x 1 x 2 mm(3). The camera performance is simulated with Geant4-based Architecture for Medicine-Oriented Simulations(GAMOS) and the Origin Ensemble(OE) algorithm is used for the image reconstruction. The simulation shows that the camera can operate with up to 10(4) Bq source activities with equal efficiency and is completely saturated at 10(9) Bq. The efficiency of the system is evaluated using a simulated F-18 point source phantom in the center of the Field-of-View (FOV) achieving an intrinsic efficiency of 0.4 counts per second per kilobecquerel. The spatial resolution measured from the point spread function (PSF) shows a FWHM of 1.5 mm along the direction perpendicular to the scatterer, making it possible to distinguish two points at 3 mm separation with a peak-to-valley ratio of 8.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Development and Evaluation of Compact and High Resolution CdTe/CZT Detectors for Handheld Gamma Camera and Probe Application
    Shen, Zeng-Ming
    Meng, Ling-Jian
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [22] Gamma ray imaging with silicon detectors - a Compton camera for radionuclide imaging in medicine
    Solomon, Christopher John
    Ott, Robert John
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 787 - 792
  • [23] The MediPROBE CdTe Based Compact Gamma Camera
    Russo, P.
    Curion, A. S.
    Mettivier, G.
    Aloj, L.
    Caraco, C.
    Lastoria, S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 556 - 558
  • [24] A prototype small CdTe gamma camera for radioguided surgery and other imaging applications
    Tsuchimochi, M
    Sakahara, H
    Hayama, K
    Funaki, M
    Ohno, R
    Shirahata, T
    Orskaug, T
    Maehlum, G
    Yoshioka, K
    Nygard, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) : 1605 - 1614
  • [25] A prototype small CdTe gamma camera for radioguided surgery and other imaging applications
    Makoto Tsuchimochi
    Harumi Sakahara
    Kazuhide Hayama
    Minoru Funaki
    Ryoichi Ohno
    Takashi Shirahata
    Terje Orskaug
    Gunnar Maehlum
    Koki Yoshioka
    Einar Nygard
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 1605 - 1614
  • [26] Optimal configuration of a low-dose breast-specific gamma camera based on semiconductor CdZnTe pixelated detectors
    Genocchi, B.
    Scienti, O. Pickford
    Darambara, D. G.
    7TH YOUNG RESEARCHER MEETING, 2017, 841
  • [27] Development of CdTe imaging detectors for a Compton Telescope
    Giboni, KL
    Aprile, E
    Oberlack, U
    GAMMA 2001, 2001, 587 : 892 - 896
  • [28] Development of CdTe pixel detectors for Compton cameras
    Watanabe, Shin
    Tanaka, Takaaki
    Oonuki, Kousuke
    Mitani, Takefumi
    Takeda, Shin'ichiro
    Kishishita, Tetsuichi
    Nakazawa, Kazuhiro
    Takahashi, Tadayuki
    Kuroda, Yoshikatsu
    Onishi, Mitsunobu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 150 - 153
  • [29] A spectroscopic Monte-Carlo model to simulate the response of pixelated CdTe based detectors
    Koch-Mehrin, K. A. L.
    Lees, J. E.
    Bugby, S. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 976
  • [30] A stacked CdTe pixel detector for a Compton camera
    Oonuki, Kousuke
    Tanaka, Takaaki
    Watanabe, Shin
    Takeda, Shin'ichiro
    Nakazawa, Kazuhiro
    Ushio, Masayoshi
    Mitani, Takefumi
    Takahashi, Tadayuki
    Tajima, Hiroyasu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 57 - 60