Evaluation of Compton gamma camera prototype based on pixelated CdTe detectors

被引:5
|
作者
Calderon, Y. [1 ]
Chmeissani, M. [1 ]
Kolstein, M. [1 ]
De Lorenzo, G. [1 ]
机构
[1] UAB, IFAE, E-08193 Bellaterra, Barcelona, Spain
来源
基金
欧洲研究理事会;
关键词
Compton imaging; Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); Solid state detectors;
D O I
10.1088/1748-0221/9/06/C06003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A proposed Compton camera prototype based on pixelated CdTe is simulated and evaluated in order to establish its feasibility and expected performance in real laboratory tests. The system is based on module units containing a 2 x 4 array of square CdTe detectors of 10 x 10 mm(2) area and 2 mm thickness. The detectors are pixelated and stacked forming a 3D detector with voxel sizes of 2 x 1 x 2 mm(3). The camera performance is simulated with Geant4-based Architecture for Medicine-Oriented Simulations(GAMOS) and the Origin Ensemble(OE) algorithm is used for the image reconstruction. The simulation shows that the camera can operate with up to 10(4) Bq source activities with equal efficiency and is completely saturated at 10(9) Bq. The efficiency of the system is evaluated using a simulated F-18 point source phantom in the center of the Field-of-View (FOV) achieving an intrinsic efficiency of 0.4 counts per second per kilobecquerel. The spatial resolution measured from the point spread function (PSF) shows a FWHM of 1.5 mm along the direction perpendicular to the scatterer, making it possible to distinguish two points at 3 mm separation with a peak-to-valley ratio of 8.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Pixelated CdTe detectors to overcome intrinsic limitations of crystal based positron emission mammographs
    De Lorenzo, G.
    Chmeissani, M.
    Uzun, D.
    Kolstein, M.
    Ozsahin, I.
    Mikhaylova, E.
    Arce, P.
    Canadas, M.
    Arino, G.
    Calderon, Y.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [32] Edge effects in pixelated CdZnTe gamma detectors
    Shor, A
    Eisen, Y
    Mardor, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2412 - 2418
  • [33] Edge effects in pixelated CdZnTe gamma detectors
    Shor, A
    Eisen, Y
    Mardor, I
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3342 - 3345
  • [34] Simulation of active-edge pixelated CdTe radiation detectors
    Duarte, D. D.
    Lipp, J. D.
    Schneider, A.
    Seller, P.
    Veale, M. C.
    Wilson, M. D.
    Baker, M. A.
    Sellin, P. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 139 - 145
  • [35] GAMMA-RAY IMAGING WITH SILICON DETECTORS - A COMPTON CAMERA FOR RADIONUCLIDE IMAGING IN MEDICINE
    SOLOMON, CJ
    OTT, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 787 - 792
  • [36] A pixellated γ-camera based on CdTe detectors clinical interests and performances
    Chambron, J
    Arntz, Y
    Eclancher, B
    Scheiber, C
    Siffert, P
    Hali, MH
    Regal, R
    Kazandjian, A
    Prat, V
    Thomas, S
    Warren, S
    Matz, R
    Jahnke, A
    Karman, M
    Pszota, A
    Nemeth, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 537 - 549
  • [37] Experimental Results of the Gamma-Ray Imaging Capability With a Si/CdTe Semiconductor Compton Camera
    Takeda, Shin'ichiro
    Aono, Hiroyuki
    Okuyama, Sho
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Watanabe, Shin
    Kokubun, Motohide
    Takahashi, Tadayuki
    Nakazawa, Kazuhiro
    TajimaHiro, Hiroyasu
    Kawachi, Naoki
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 783 - 790
  • [38] Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging
    Russo, Paolo
    Curion, Assunta S.
    Mettivier, Giovanni
    Esposito, Michela
    Aurilio, Michela
    Caraco, Corradina
    Aloj, Luigi
    Lastoria, Secondo
    MEDICAL PHYSICS, 2011, 38 (03) : 1547 - 1560
  • [39] A Prototype VP-PET Imaging System Based on Highly Pixelated CdZnTe Detectors
    Yin, Yongzhi
    Li, Yingguo
    Wang, Tianguan
    Huang, Chuan
    Ye, Zhenqian
    Li, Gongping
    SENSORS, 2020, 20 (05)
  • [40] C-SPRINT: A prototype Compton camera system for low energy gamma ray imaging
    LeBlanc, JW
    Clinthorne, NH
    Hua, CH
    Nygard, E
    Rogers, WL
    Wehe, DK
    Weilhammer, P
    Wilderman, SJ
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 357 - 361