Dual-layer spectral detector CT monoenergetic reconstruction improves image quality of non-contrast cerebral CT as compared with conventional single energy CT

被引:19
|
作者
Zhao, Xue-Mei [1 ,2 ]
Wang, Man [1 ,2 ]
Wu, Run-Ze [3 ]
Dharaiya, Ekta [4 ]
Feng, Feng [1 ,2 ]
Li, Ming-Li [1 ,2 ]
You, Hui [1 ,2 ]
Wang, Yun [1 ,2 ]
Wang, Yi-Ning [1 ,2 ]
Jin, Zheng-Yu [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China
[2] Peking Union Med Coll, Beijing 100730, Peoples R China
[3] Philips Healthcare, Clin Sci, Beijing, Peoples R China
[4] Philips Hlth Tech, Clin Sci, Cambridge, MA USA
基金
中国国家自然科学基金;
关键词
Dual-energy computed tomography; Monoenergetic imaging; Image contrast and quality; Neuroradiology; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IODINATED CONTRAST; HEMORRHAGE; DIAGNOSIS; BRAIN;
D O I
10.1016/j.ejrad.2018.04.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate and compare image quality of monoenergetic reconstructions from spectral NCCT to conventional 120 kVp images acquired at a similar dose. Materials and methods: Patients undergoing NCCT on a dual-layer spectral detector CT (n=30) and a conventional CT (n= 30) were enrolled in the study. The spectral detector CT data was reconstructed at monoenergetic images from 40 to 140 keV in 5-keV increments and 65-70 keV in 1-keV increments (Group A1) and using single energy CT equivalent reconstruction (Group A2). The reference conventional 120kVp images (Group B) were acquired using a standard-of-care protocol with the same radiation dose. We evaluated the image quality of monoenergetic images and determined the optimal keV level using HU attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), artifact evaluation in posterior fossa by placing region-of-interest (ROI) and subjective image score by 2 radiologists independently using a 4-point scale (1-excellent, 4-undiagnostic). Results: The SNR and subjective image score were optimal at 66-70keV, while monoenergetic 68 keV images with a higher SNR (18.48 +/- 1.94, 15.55 +/- 1.56 and 14.33 +/- 1.38 for Group 68keV, A2 and B respectively, p < 0.001), CNR (4.09 +/- 0.65, 3.43 +/- 0.56 and 3.52 +/- 0.55 for Group 68keV, A2 and B respectively, p < 0.001) and a lower noise (1.80 +/- 0.19, 2.11 +/- 0.19 and 2.25 +/- 0.25 for Group 68keV, A2 and B respectively, p < 0.001). Conclusion: Spectral NCCT monoenergetic reconstructions at 68 keV improve image quality and reduce artifact compared to conventional single energy CT without radiation dose penalty.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [11] Dual-layer spectral CT improves image quality of multiphasic pancreas CT in patients with pancreatic ductal adenocarcinoma
    Yasunori Nagayama
    Shota Tanoue
    Taihei Inoue
    Seitaro Oda
    Takeshi Nakaura
    Daisuke Utsunomiya
    Yasuyuki Yamashita
    [J]. European Radiology, 2020, 30 : 394 - 403
  • [12] Quantifying potential reduction in contrast dose with monoenergetic images synthesized from dual-layer detector spectral CT
    Tsang, Derek S.
    Merchant, Thomas E.
    Merchant, Sophie E.
    Yagil, Hanna Smith Yoad
    Yagil, Yoad
    Hua, Chia-Ho
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1078):
  • [13] Acute infarction after mechanical thrombectomy is better delineable in virtual non-contrast compared to conventional images using a dual-layer spectral CT
    Riederer, Isabelle
    Fingerle, Alexander A.
    Baum, Thomas
    Kirschke, Jan S.
    Rummeny, Ernst J.
    Noel, Peter B.
    Pfeiffer, Daniela
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [14] Acute infarction after mechanical thrombectomy is better delineable in virtual non-contrast compared to conventional images using a dual-layer spectral CT
    Isabelle Riederer
    Alexander A. Fingerle
    Thomas Baum
    Jan S. Kirschke
    Ernst J. Rummeny
    Peter B. Noël
    Daniela Pfeiffer
    [J]. Scientific Reports, 8
  • [15] Objective image characterization of a spectral CT scanner with dual-layer detector
    Ozguner, Orhan
    Dhanantwari, Amar
    Halliburton, Sandra
    Wen, Gezheng
    Utrup, Steven
    Jordan, David
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02):
  • [16] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [17] Image quality evaluation of dual-layer spectral CT in comparison to single-layer CT in a reduced-dose setting
    Thuy Duong Do
    Rheinheimer, Stephan
    Kauczor, Hans-Ulrich
    Stiller, Wolfram
    Weber, Tim
    Skornitzke, Stephan
    [J]. EUROPEAN RADIOLOGY, 2020, 30 (10) : 5709 - 5719
  • [18] Leveraging non-contrast head CT to improve the image quality of cerebral CT perfusion maps
    Harvey, Evan C.
    Li, Ke
    [J]. JOURNAL OF MEDICAL IMAGING, 2020, 7 (06)
  • [19] Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
    Lundin, Margareta
    Liden, Mats
    Magnuson, Anders
    Mohammed, Ahmed Abdulilah
    Geijer, Hakan
    Andersson, Torbjorn
    Persson, Anders
    [J]. ACTA RADIOLOGICA, 2012, 53 (06) : 689 - 694
  • [20] Image quality evaluation of dual-layer spectral CT in comparison to single-layer CT in a reduced-dose setting
    Thuy Duong Do
    Stephan Rheinheimer
    Hans-Ulrich Kauczor
    Wolfram Stiller
    Tim Weber
    Stephan Skornitzke
    [J]. European Radiology, 2020, 30 : 5709 - 5719