Objective image characterization of a spectral CT scanner with dual-layer detector

被引:46
|
作者
Ozguner, Orhan [1 ,2 ]
Dhanantwari, Amar [2 ]
Halliburton, Sandra [2 ]
Wen, Gezheng [2 ,3 ]
Utrup, Steven [2 ]
Jordan, David [4 ,5 ]
机构
[1] Case Western Reserve Univ, Comp Sci, Cleveland, OH 44106 USA
[2] Philips Healthcare, Cleveland, OH 44143 USA
[3] Univ Texas Austin, Elect & Comp Engn, Austin, TX 78712 USA
[4] Univ Hosp Cleveland, Med Ctr, Radiol, Cleveland, OH 44106 USA
[5] Case Western Reserve Univ, Radiol, Cleveland, OH 44106 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 02期
关键词
detector-based spectral CT; dual energy; image performance analysis; ENERGY COMPUTED-TOMOGRAPHY; NOISE POWER SPECTRUM; STONE COMPOSITION; BONE REMOVAL; QUANTIFICATION; ANGIOGRAPHY; QUALITY; PHANTOM;
D O I
10.1088/1361-6560/aa9e1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital's clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm(-1). NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Objective Image Characterization of Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Halliburton, S.
    Dhanantwari, A.
    Wen, G.
    Utrup, S.
    Jordan, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3836 - 3836
  • [2] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [3] Image quality evaluation of dual-layer spectral detector CT of the chest and comparison with conventional CT imaging
    Doerner, Jonas
    Hauger, Myriam
    Hickethier, Tilman
    Byrtus, Jonathan
    Wybranski, Christian
    Hokamp, Nils Grosse
    Maintz, David
    Haneder, Stefan
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 52 - 58
  • [4] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    [J]. CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [5] Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
    Morita, Koichiro
    Nishie, Akihiro
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Kubo, Yuichiro
    Ishimatsu, Keisuke
    Yoshizumi, Tomoharu
    Maehara, Junki
    Ishigami, Kousei
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [6] SNR performance comparison of dual-layer detector and dual-kVp spectral CT
    Heismann, B. J.
    Wirth, S.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3820 - 3822
  • [7] Dose of CT protocols acquired in clinical routine using a dual-layer detector CT scanner: A preliminary report
    van Ommen, F.
    de Jong, H. W. A. M.
    Dankbaar, J. W.
    Bennink, E.
    Leiner, T.
    Schilham, A. M. R.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2019, 112 : 65 - 71
  • [8] Detector-based spectral CT with a novel dual-layer technology: principles and applications
    Rassouli, Negin
    Etesami, Maryam
    Dhanantwari, Amar
    Rajiah, Prabhakar
    [J]. INSIGHTS INTO IMAGING, 2017, 8 (06): : 589 - 598
  • [9] Unenhanced Dual-Layer Spectral-Detector CT for Characterizing Indeterminate Adrenal Lesions
    Nagayama, Yasunori
    Inoue, Taihei
    Oda, Seitaro
    Tanoue, Shota
    Nakaura, Takeshi
    Morinaga, Jun
    Ikeda, Osamu
    Hirai, Toshinori
    [J]. RADIOLOGY, 2021, 301 (02) : 369 - 378
  • [10] Detector-based spectral CT with a novel dual-layer technology: principles and applications
    Negin Rassouli
    Maryam Etesami
    Amar Dhanantwari
    Prabhakar Rajiah
    [J]. Insights into Imaging, 2017, 8 : 589 - 598