Objective image characterization of a spectral CT scanner with dual-layer detector

被引:46
|
作者
Ozguner, Orhan [1 ,2 ]
Dhanantwari, Amar [2 ]
Halliburton, Sandra [2 ]
Wen, Gezheng [2 ,3 ]
Utrup, Steven [2 ]
Jordan, David [4 ,5 ]
机构
[1] Case Western Reserve Univ, Comp Sci, Cleveland, OH 44106 USA
[2] Philips Healthcare, Cleveland, OH 44143 USA
[3] Univ Texas Austin, Elect & Comp Engn, Austin, TX 78712 USA
[4] Univ Hosp Cleveland, Med Ctr, Radiol, Cleveland, OH 44106 USA
[5] Case Western Reserve Univ, Radiol, Cleveland, OH 44106 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 02期
关键词
detector-based spectral CT; dual energy; image performance analysis; ENERGY COMPUTED-TOMOGRAPHY; NOISE POWER SPECTRUM; STONE COMPOSITION; BONE REMOVAL; QUANTIFICATION; ANGIOGRAPHY; QUALITY; PHANTOM;
D O I
10.1088/1361-6560/aa9e1b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital's clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm(-1). NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Value of dual-layer spectral detector CT in differential diagnosis of lung cancer and inflammatory nodules
    傅奕铖
    [J]. China Medical Abstracts (Internal Medicine), 2022, (01) : 1 - 2
  • [22] Dual-Layer Detector Spectral CT Performance: Quantitative Accuracy and Precision of Iodine Concentration Measurements
    Zhao, X.
    Hameed, T.
    Hutchins, G.
    Liang, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3233 - 3233
  • [23] Dual-layer spectral detector CT: predicting the invasiveness of pure ground-glass adenocarcinoma
    Yu, Y.
    Fu, Y.
    Chen, X.
    Zhang, Y.
    Zhang, F.
    Li, X.
    Zhao, X.
    Cheng, J.
    Wu, H.
    [J]. CLINICAL RADIOLOGY, 2022, 77 (06) : E458 - E465
  • [24] Initial exploration of coronary stent image subtraction using dual-layer spectral CT
    Qin, Le
    Gu, ShengJia
    Chen, ChiHua
    Zhang, Huan
    Zhu, ZhenBin
    Chen, XingBiao
    Han, Qun
    Yan, FuHua
    Yang, WenJie
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (08) : 4239 - 4248
  • [25] Initial exploration of coronary stent image subtraction using dual-layer spectral CT
    Le Qin
    ShengJia Gu
    ChiHua Chen
    Huan Zhang
    ZhenBin Zhu
    XingBiao Chen
    Qun Han
    FuHua Yan
    WenJie Yang
    [J]. European Radiology, 2019, 29 : 4239 - 4248
  • [26] Low Dose and Low Contrast Medium Coronary CT Angiography Using Dual-Layer Spectral Detector CT
    Yi, Yan
    Zhao, Xue-Mei
    Wu, Run-Ze
    Wang, Yun
    Vembar, Mani
    Jin, Zheng-Yu
    Wang, Yi-Ning
    [J]. INTERNATIONAL HEART JOURNAL, 2019, 60 (03) : 608 - 617
  • [27] Dual-layer spectral detector CT monoenergetic reconstruction improves image quality of non-contrast cerebral CT as compared with conventional single energy CT
    Zhao, Xue-Mei
    Wang, Man
    Wu, Run-Ze
    Dharaiya, Ekta
    Feng, Feng
    Li, Ming-Li
    You, Hui
    Wang, Yun
    Wang, Yi-Ning
    Jin, Zheng-Yu
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 103 : 131 - 138
  • [28] Clinical Usefulness of Dual-Energy Cardiac Computed Tomography in Acute Coronary Syndrome Using a Dual-Layer Spectral Detector Scanner
    Nishihara, Taiki
    Oda, Seitaro
    Sueta, Daisuke
    Izumiya, Yasuhiro
    Kaikita, Koichi
    Tsujita, Kenichi
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (02)
  • [29] Imaging findings of primary vaginal malignancies by dual-layer spectral detector CT: description of two patients
    Cui, Yuanyuan
    Zhang, Zhengwei
    Zhang, Xiaohui
    Zhao, Baolian
    Shi, Xiaolei
    Zhu, Zhi
    Liu, Xiaojun
    Liu, Shiyuan
    Xiao, Yi
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 1245 - 1251
  • [30] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    van Hamersvelt, Robbert W.
    Schilham, Arnold M. R.
    Engelke, Klaus
    den Harder, Annemarie M.
    de Keizer, Bart
    Verhaar, Harald J.
    Leiner, Tim
    de Jong, Pim A.
    Willemink, Martin J.
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (10) : 4351 - 4359