Dual-layer spectral detector CT monoenergetic reconstruction improves image quality of non-contrast cerebral CT as compared with conventional single energy CT

被引:19
|
作者
Zhao, Xue-Mei [1 ,2 ]
Wang, Man [1 ,2 ]
Wu, Run-Ze [3 ]
Dharaiya, Ekta [4 ]
Feng, Feng [1 ,2 ]
Li, Ming-Li [1 ,2 ]
You, Hui [1 ,2 ]
Wang, Yun [1 ,2 ]
Wang, Yi-Ning [1 ,2 ]
Jin, Zheng-Yu [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China
[2] Peking Union Med Coll, Beijing 100730, Peoples R China
[3] Philips Healthcare, Clin Sci, Beijing, Peoples R China
[4] Philips Hlth Tech, Clin Sci, Cambridge, MA USA
基金
中国国家自然科学基金;
关键词
Dual-energy computed tomography; Monoenergetic imaging; Image contrast and quality; Neuroradiology; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IODINATED CONTRAST; HEMORRHAGE; DIAGNOSIS; BRAIN;
D O I
10.1016/j.ejrad.2018.04.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate and compare image quality of monoenergetic reconstructions from spectral NCCT to conventional 120 kVp images acquired at a similar dose. Materials and methods: Patients undergoing NCCT on a dual-layer spectral detector CT (n=30) and a conventional CT (n= 30) were enrolled in the study. The spectral detector CT data was reconstructed at monoenergetic images from 40 to 140 keV in 5-keV increments and 65-70 keV in 1-keV increments (Group A1) and using single energy CT equivalent reconstruction (Group A2). The reference conventional 120kVp images (Group B) were acquired using a standard-of-care protocol with the same radiation dose. We evaluated the image quality of monoenergetic images and determined the optimal keV level using HU attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), artifact evaluation in posterior fossa by placing region-of-interest (ROI) and subjective image score by 2 radiologists independently using a 4-point scale (1-excellent, 4-undiagnostic). Results: The SNR and subjective image score were optimal at 66-70keV, while monoenergetic 68 keV images with a higher SNR (18.48 +/- 1.94, 15.55 +/- 1.56 and 14.33 +/- 1.38 for Group 68keV, A2 and B respectively, p < 0.001), CNR (4.09 +/- 0.65, 3.43 +/- 0.56 and 3.52 +/- 0.55 for Group 68keV, A2 and B respectively, p < 0.001) and a lower noise (1.80 +/- 0.19, 2.11 +/- 0.19 and 2.25 +/- 0.25 for Group 68keV, A2 and B respectively, p < 0.001). Conclusion: Spectral NCCT monoenergetic reconstructions at 68 keV improve image quality and reduce artifact compared to conventional single energy CT without radiation dose penalty.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [31] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    [J]. CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [32] Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
    Morita, Koichiro
    Nishie, Akihiro
    Ushijima, Yasuhiro
    Takayama, Yukihisa
    Fujita, Nobuhiro
    Kubo, Yuichiro
    Ishimatsu, Keisuke
    Yoshizumi, Tomoharu
    Maehara, Junki
    Ishigami, Kousei
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136
  • [33] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Francesco Marcello Arico’
    Renato Trimarchi
    Antonio Portaluri
    Claudia Barilla’
    Nicola Migliaccio
    Giuseppe Mauro Bucolo
    Giuseppe Cicero
    Carmelo Sofia
    Christian Booz
    Thomas J. Vogl
    Maria Adele Marino
    Velio Ascenti
    Tommaso D’Angelo
    Silvio Mazziotti
    Giorgio Ascenti
    [J]. La radiologia medica, 2023, 128 : 891 - 899
  • [34] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Arico, Francesco Marcello
    Trimarchi, Renato
    Portaluri, Antonio
    Barilla, Claudia
    Migliaccio, Nicola
    Bucolo, Giuseppe Mauro
    Cicero, Giuseppe
    Sofia, Carmelo
    Booz, Christian
    Vogl, Thomas J. J.
    Marino, Maria Adele
    Ascenti, Velio
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Ascenti, Giorgio
    [J]. RADIOLOGIA MEDICA, 2023, 128 (08): : 891 - 899
  • [35] Combining non-contrast and dual-energy CT improves diagnosis of early gout
    Lee, Seul Ki
    Jung, Joon-Yong
    Jee, Won-Hee
    Lee, Jennifer Jooha
    Park, Sung-Hwan
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (03) : 1267 - 1275
  • [36] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Felix G. Gassert
    Claudio E. Schacky
    Christina Müller-Leisse
    Florian T. Gassert
    Gregor Pahn
    Karl-Ludwig Laugwitz
    Marcus R. Makowski
    Jonathan Nadjiri
    [J]. European Radiology, 2021, 31 : 6193 - 6199
  • [37] Virtual Unenhanced Dual Energy CT improves position verification compared to contrast CT
    Bulthuis, L.
    Afifah, M.
    Goudschaal, K.
    Den Boer, D.
    Rosario, T.
    Verbeek, J.
    Bel, A.
    Van Kesteren, Z.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S292 - S293
  • [38] Combining non-contrast and dual-energy CT improves diagnosis of early gout
    Seul Ki Lee
    Joon-Yong Jung
    Won-Hee Jee
    Jennifer Jooha Lee
    Sung-Hwan Park
    [J]. European Radiology, 2019, 29 : 1267 - 1275
  • [39] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Gassert, Felix G.
    Schacky, Claudio E.
    Mueller-Leisse, Christina
    Gassert, Florian T.
    Pahn, Gregor
    Laugwitz, Karl-Ludwig
    Makowski, Marcus R.
    Nadjiri, Jonathan
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (08) : 6193 - 6199
  • [40] Virtual monoenergetic dual-energy CT reconstructions at 80 keV are optimal non-contrast CT technique for early stroke detection
    Dodig, Doris
    Kastelan, Zrinka Matana
    Bartolovic, Nina
    Jurkovic, Slaven
    Miletic, Damir
    Rumboldt, Zoran
    [J]. NEURORADIOLOGY JOURNAL, 2022, 35 (03): : 337 - 345