Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: and in vivo and in vitro study

被引:14
|
作者
Kim, Hee-Kyung [1 ]
机构
[1] Ajou Univ, Sch Med, Dept Dent, 164 World Cup Ro, Suwon 16499, South Korea
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2018年 / 10卷 / 03期
关键词
Spectrophotometry; Color; Equipment failure analysis; Dimensional measurement accuracy; TOOTH COLOR; INTERDEVICE AGREEMENT; SHADE GUIDES; RELIABILITY; DEVICES; SYSTEM; THRESHOLDS; CIEDE2000; SELECTION; FORMULA;
D O I
10.4047/jap.2018.10.3.252
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VIVA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (alpha=.05). RESULTS. A high level of measurement repeatability (ICC>0.90) among L*, a*, and Lo 5 color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were 2.28 +/- 1.61 Delta E-00 for in-vivo readings. Regarding the clinical matching accuracy of both devices, Delta E-00 values between teeth and matching shade tabs were 3.05 +/- 1.19 and 2.86 +/- 1.02, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE L*, a*, and b* measurements, they could provide different color values and shade for the same tooth.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 50 条
  • [1] MATCHING REPEATABILITY AND INTERDEVICE AGREEMENT OF 2 INTRAORAL SPECTROPHOTOMETERS
    Sarafianou, Aspasia
    Kamposiora, Phophi
    Papavasiliou, George
    Goula, Helen
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2012, 107 (03): : 178 - 185
  • [2] Accuracy evaluation of two different intraoral scanners in implant prosthodontics. A comparative in vitro study
    Verniani, G.
    Casucci, A.
    Nosrati, N.
    D'Arienzo, L. F.
    Val, M.
    Cagidiaco, E. Ferrari
    [J]. JOURNAL OF OSSEOINTEGRATION, 2024, 16 (01) : 61 - 64
  • [3] Evaluation of accuracy and characteristics of tooth-color matching by intraoral scanners based on Munsell color system: an in vivo study
    Mingming Huang
    Hongqiang Ye
    Hu Chen
    Yongsheng Zhou
    Yunsong Liu
    Yong Wang
    Yuchun Sun
    [J]. Odontology, 2022, 110 : 759 - 768
  • [4] Evaluation of accuracy and characteristics of tooth-color matching by intraoral scanners based on Munsell color system: an in vivo study
    Huang, Mingming
    Ye, Hongqiang
    Chen, Hu
    Zhou, Yongsheng
    Liu, Yunsong
    Wang, Yong
    Sun, Yuchun
    [J]. ODONTOLOGY, 2022, 110 (04) : 759 - 768
  • [5] In vitro Evaluation of Accuracy of Single Dies Captured by Two Intraoral Digital Scanners
    Burde, Alexandru Victor
    Gasparik, Cristina
    Moldovan, Marioara
    Baciu, Sorana
    Cosma, Cosmin
    [J]. MATERIALE PLASTICE, 2018, 55 (02) : 176 - 178
  • [6] Direct accuracy measurement through repeatability of an intraoral scanner: a clinical study
    Monteiro, Paulo
    Martins, Joana
    Rua, Joao
    Delgado, Antonio
    Mendes, Jose Joo
    [J]. ANNALS OF MEDICINE, 2018, 50 : S83 - S83
  • [7] Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: An in-vitro study
    Su, Ting-shu
    Sun, Jian
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2015, 59 (04) : 236 - 242
  • [8] In vitro evaluation of the accuracy and precision of intraoral and extraoral scans
    Baghani, Mohammad Taghi
    Shayegh, Sayed Shojaedin
    Johnston, William M.
    Shidfar, Shireen
    Hakimaneh, Seyed Mohammad Reza
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (05): : 665 - 670
  • [9] Effect of preparation type on the accuracy of different intraoral scanners: An in vitro study at different levels of accuracy evaluation
    Abduo, Jaafar
    Laskey, David
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (08) : 1221 - 1229
  • [10] In Vivo and in Vitro Evaluations of Repeatability and Accuracy of VITA Easyshade (R) Advance 4.0 Dental Shade-Matching Device
    Zlataric, Dubravka Knezovic
    illes, Davor
    Alajbeg, Iva Z.
    Zagar, Maja
    [J]. ACTA STOMATOLOGICA CROATICA, 2015, 49 (02) : 112 - 118