Evaluation of accuracy and characteristics of tooth-color matching by intraoral scanners based on Munsell color system: an in vivo study

被引:3
|
作者
Huang, Mingming [1 ]
Ye, Hongqiang [1 ,2 ]
Chen, Hu [1 ]
Zhou, Yongsheng [2 ]
Liu, Yunsong [2 ]
Wang, Yong [1 ]
Sun, Yuchun [1 ]
机构
[1] Peking Univ, Res Ctr Engn & Technol Computerized Dent,Minist H, Natl Ctr Stomatol,Natl Clin Res Ctr Oral Dis,Natl, Ctr Digital Dent,Fac Prosthodont,Ctr Oral Biomat, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
[2] Peking Univ, Natl Ctr Stomatol,Natl Clin Res Ctr Oral Dis,Natl, Beijing Key Lab Digital Stomatol,Res Ctr Engn & T, Minist Hlth,NMPA Key Lab Dent Mat,Sch & Hosp Stom, Beijing 100081, Peoples R China
基金
国家重点研发计划;
关键词
Shade matching; Shade guide; Spectrophotometer; Intraoral scanner; Visual; PART I; SHADE; REPEATABILITY; PERFORMANCE; DENTISTRY; EDUCATION; DEVICES; CHROMA; IMPACT;
D O I
10.1007/s10266-022-00694-9
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To compare the accuracy of visual and instrumental methods for tooth-color matching based on three attributes in the Munsell color system and to investigate the characteristics of intraoral scanners for tooth-color matching. Shades of the cervical, middle, and incisal third region of 130 maxillary anterior teeth were matched visually by an experienced prosthodontist (EP) using Vita classical A1-D4 (VC) and Vita System 3D-Master (V3D) shade guides, and digitally by a spectrophotometer (Vita Easyshade V, VE) and two intraoral scanners (3Shape TRIOS 3, T3; TRIOS 4, T4). VE was used as a reference. The reproducibility of the three test groups was examined by repeating the measurements in triplicate. The overall trueness of the three test groups (from high to low) was T3 > EP > T4 for VC values (p < 0.01), and T3, EP > T4 (p < 0.01) for V3D. The trueness of T3 in incisal regions was lower than cervical and middle regions. When hue or lightness was correct, the mismatched chroma in test groups was smaller than VE (p < 0.01). The repeatability of EP was the poorest (p < 0.01). The color-matching trueness of T3 was higher than EP and T4. The reproducibility of intraoral scanners was better than visual methodology.
引用
收藏
页码:759 / 768
页数:10
相关论文
共 16 条
  • [1] Evaluation of accuracy and characteristics of tooth-color matching by intraoral scanners based on Munsell color system: an in vivo study
    Mingming Huang
    Hongqiang Ye
    Hu Chen
    Yongsheng Zhou
    Yunsong Liu
    Yong Wang
    Yuchun Sun
    [J]. Odontology, 2022, 110 : 759 - 768
  • [2] Evaluation of the accuracy and limitations of three tooth-color measuring machines
    Chang, Jiun-Yao
    Chen, Wen-Cheng
    Huang, Ta-Ko
    Wang, Jen-Chyan
    Fu, Po-Sung
    Chen, Jeng-Huey
    Hung, Chun-Cheng
    [J]. JOURNAL OF DENTAL SCIENCES, 2015, 10 (01) : 16 - 20
  • [3] Evaluating the accuracy of tooth color measurement by combining the Munsell color system and dental colorimeter
    Chang, Jiun-Yao
    Chen, Wen-Cheng
    Huang, Ta-Ko
    Wang, Jen-Chyan
    Fu, Po-Sung
    Chen, Jeng-Huey
    Hung, Chun-Cheng
    [J]. KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2012, 28 (09): : 490 - 494
  • [4] In vivo tooth-color measurement with a new 3D intraoral scanning system in comparison to conventional digital and visual color determination methods
    Mehl, A.
    Bosch, G.
    Fischer, C.
    Ender, A.
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (04) : 343 - 361
  • [5] Mechanical Properties and Accuracy Evaluation of 3D Printing Based on Value in the Munsell Color System
    Huang, Jianping
    Ye, Wanxiang
    Ye, Guihua
    Jia, Qi
    Li, Kelun
    Kong, Jiawen
    Jiang, Heng Bo
    Lan, Qing
    Yu, Liming
    [J]. ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [6] Study on Colors of Modern Historical Buildings of Wuhan University Based on Munsell Color System
    Wang, Ying
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ECONOMICS, MANAGEMENT, LAW AND EDUCATION (EMLE 2017), 2017, 32 : 257 - 260
  • [7] Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: and in vivo and in vitro study
    Kim, Hee-Kyung
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (03): : 252 - 258
  • [8] Study on Color Matching of Building Facades in Harbin (Cold Regions) Based on NCS Color System
    Shao, Yu
    Liu, Jie
    Wang, Jirui
    Song, Wenjie
    [J]. PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON CIVIL, TRANSPORTATION AND ENVIRONMENTAL ENGINEERING (ICCTE 2017), 2017, 135 : 220 - 223
  • [9] Influence of tooth preparation design and scan angulations on the accuracy of two intraoral digital scanners: An in vitro study based on 3-dimensional comparisons
    Ammoun, R.
    Suprono, M. S.
    Goodacre, C. J.
    Oyoyo, U.
    Carrico, C. K.
    Kattadiyil, M. T.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (06): : 785 - 785
  • [10] Influence of Tooth Preparation Design and Scan Angulations on the Accuracy of Two Intraoral Digital Scanners: An in Vitro Study Based on 3-Dimensional Comparisons
    Ammoun, Rami
    Suprono, Montry S.
    Goodacre, Charles J.
    Oyoyo, Udochukwu
    Carrico, Caroline K.
    Kattadiyil, Mathew T.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (03): : 201 - 206