Voxel dosimetry: Comparison of MCNPX and DOSXYZnrc Monte Carlo codes in patient specific phantom calculations

被引:3
|
作者
Hadad, Kamal [1 ]
Saeedi-Moghadam, Mahdi [2 ]
Zeinali-Rafsanjani, Banafsheh [2 ,3 ]
机构
[1] Shiraz Univ, Sch Mech Engn, Dept Nucl Engn, Shiraz, Iran
[2] Shiraz Univ Med Sci, Med Imaging Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Nucl Med & Mol Imaging Res Ctr, Shiraz, Iran
关键词
MCNPX; EGSnrc; voxel phantom; patient specific phantom; DOSXYZnrc; DVH; HYBRID COMPUTATIONAL PHANTOMS; CANCER-RISK ESTIMATION; RADIATION-THERAPY; DOSE CALCULATION; HUMAN ANATOMY; VALIDATION; EGS4; ELECTRON; MODELS; TOOL;
D O I
10.3233/THC-161240
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
INTRODUCTION: Dose evaluation with two Monte Carlo codes using patient specific voxel phantom is presented in this paper. We employ both MCNPX and DOSXYZnrc to perform dosimetry for mathematical voxel phantoms generated by our in-house developed voxel phantom generator and EGSnrc/CTCreate respectively. MATERIAL AND METHOD: Our case study was a 2.5 x 2.4 x 2.4 cm(3) tumor in the middle lobe of right lung of a male patient exposed to 6MV parallel beam. In order to compare these Monte Carlo codes with together gross tumor volume (GTV) and organ at risks (OAR) doses and dose volume histograms (DVH) were calculated. RESULTS: Comparing the mean absorbed dose results (in Gy) from both codes indicates that gross tumor volume, heart and spinal cord have 2% to 10% difference. The 10% difference between the codes were from the spinal cord region where was not in the therapy beam and it just received the scatter radiation. The dose volume DVH obtained from DOSXYZnrc results demonstrate a milder slope compared with MCNPX DVHs. CONCLUSION: It was revealed that MCNPX has some advantages in comparison to DOSXYZnrc, but it is important to consider that for equal precision in voxel dosimetry calculation, DOSXYZnrc runs faster than MCNPX and it is a great advantage.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [21] Effect of voxel size when calculating patient specific radionuclide dosimetry estimates using direct Monte Carlo simulation
    Kevin J. Hickson
    Graeme J. O’Keefe
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 495 - 503
  • [22] EFFECT OF VOXEL SIZE WHEN CALCULATING PATIENT SPECIFIC RADIONUCLIDE DOSIMETRY ESTIMATES USING DIRECT MONTE CARLO SIMULATION
    Hickson, K.
    O'Keefe, G.
    Scott, A. M.
    INTERNAL MEDICINE JOURNAL, 2012, 42 : 42 - 42
  • [23] Effect of voxel size when calculating patient specific radionuclide dosimetry estimates using direct Monte Carlo simulation
    Hickson, Kevin J.
    O'Keefe, Graeme J.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) : 495 - 503
  • [24] Comparison of treatment planning dose calculations with measurements and Monte Carlo calculations in a RANDO phantom
    Wyatt, M
    Corredor, C
    Tamimi, M
    Miller, LF
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 461 - 465
  • [25] Monte-Carlo (MC) simulation and calculation of the specific absorbed fractions (SAFs) of radiation energy for internal dosimetry using a VOXEL phantom of a piglet
    Kranz, Mathias
    Sattler, Bernhard
    Desbree, Aurelie
    Rullmann, Michael
    Deuther-Conrad, Winnie
    Steinbach, Joerg
    Brust, Peter
    Sabri, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [26] Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources
    Chiavassa, S
    Lemosquet, A
    Aubineau-Lanièce, I
    de Carlan, L
    Clairand, I
    Ferrer, L
    Bardiès, M
    Franck, D
    Zankl, M
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 631 - 635
  • [27] Benchmarking BrachyDose: Voxel based EGSnrc Monte Carlo calculations of TG-43 dosimetry parameters
    Taylor, R. E. P.
    Yegin, G.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2007, 34 (02) : 445 - 457
  • [28] Evaluation of a patient-specific Monte Carlo software for CT dosimetry
    Myronakis, Marios
    Perisinakis, Kostas
    Tzedakis, Antonis
    Gourtsoyianni, Sofia
    Damilakis, John
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 248 - 255
  • [29] Monte Carlo based voxel phantoms for in vivo internal dosimetry
    Gomez Ros, J. M.
    Moraleda, M.
    Lopez, M. A.
    Navarro, T.
    Navarro, J. F.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 161 - 165
  • [30] Effect of voxel size on Monte Carlo dose calculations
    Qin, L
    Yang, J
    Li, J
    Chen, L
    Price, R
    Ma, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1883 - 1883