Comparison of treatment planning dose calculations with measurements and Monte Carlo calculations in a RANDO phantom

被引:6
|
作者
Wyatt, M [1 ]
Corredor, C [1 ]
Tamimi, M [1 ]
Miller, LF [1 ]
机构
[1] Univ Tennessee, Knoxville, TN 37996 USA
关键词
D O I
10.1093/rpd/nci203
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solid tumours are often treated with external beams of photons generated by Bremsstrahlung radiation. These beams are shaped and filtered to optimise the dose to specific regions defined by the treatment plans, which may involve irradiations from multiple angles. It is important that doses to healthy tissue do not exceed tolerance doses and that the dose to the tumour is maximised. To accomplish these objectives, commercially available 3-D treatment planning software is used to calculate doses to healthy tissue and to the tumour. It is generally believed that these commercial software packages calculate doses through the patient to within a few per cent. In order to examine this claim, dose calculations obtained from ADAC software for external beam treatment to the pelvic region of a RANDO phantom are compared with 37 thermoluminescence dosemeters placed into several slices of a RANDO phantom. The phantom was irradiated to obtain a prescription dose of 180 cGy at the tumour location. Data from homogeneous regions agree within several per cent with results obtained from ADAC software, whereas this comparison is less favourable in regions of heterogeneity. Results from Monte Carlo calculations in a homogeneous phantom are comparable to results from ADAC treatment planning software.
引用
收藏
页码:461 / 465
页数:5
相关论文
共 50 条
  • [1] Electron Monte Carlo Comparison to Hand Calculations and Phantom Measurements
    Chu, K.
    Potari, V.
    Rostock, R.
    DeLuca, M.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E250 - E250
  • [2] Experimental validation of Monte Carlo calculations with a voxelized Rando-Alderson phantom: a study on influence parameters
    Struelens, Lara
    Vanhavere, Filip
    Smans, Kristien
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5831 - 5844
  • [3] Validation of Monte Carlo dose planning calculations by epithermal beam: Dose distribution measurements in phantoms
    Carolan, MG
    Wallace, SA
    Allen, BJ
    Rosenfeld, AB
    Mathur, JN
    Meriaty, HA
    StecherRasmussen, F
    Moss, RL
    Raaijmakers, CPJ
    Konijnenberg, MW
    [J]. CANCER NEUTRON CAPTURE THERAPY, 1996, : 303 - 310
  • [4] Monte Carlo calculations of dose profiles with the 'given profile" method and comparison with measurements
    Poudel, Suresh
    Kulshreshtha, Asita
    Abu Zakaria, Golam
    Hartmann, Guenther H.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 213
  • [5] COMPARISON OF FIELD DOSE-RATE MEASUREMENTS AND MONTE-CARLO CALCULATIONS
    KOBLINGER, L
    NEMETH, I
    ZOMBORI, P
    ANDRASI, A
    [J]. ACTA PHYSICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1982, 52 (3-4): : 397 - 404
  • [6] Effect of voxel size on Monte Carlo dose calculations for radiotherapy treatment planning
    Mora, G
    Pawlicki, T
    Maio, A
    Ma, CM
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 549 - 554
  • [7] Inverse treatment planning using volume sampling with Monte Carlo dose calculations
    Craig, J.
    Wong, E.
    Gladwish, A.
    Oliver, M.
    Chen, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2114 - 2115
  • [8] Monte Carlo dose calculations in a phantom irradiated with typical beams of radiotherapy
    Mora, G
    Maio, A
    Rogers, DWO
    Pawlicki, T
    Kapur, A
    Ma, CM
    [J]. PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 693 - 696
  • [9] A flexible Monte Carlo tool for patient or phantom specific calculations: comparison with preliminary validation measurements
    Davidson, S.
    Cui, J.
    Followill, D.
    Ibbott, G.
    Deasy, J.
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [10] Dynamic IMRT treatments of sinus region tumors: Comparison of Monte Carlo calculations with treatment planning system calculations and ion chamber measurements
    Chin, D.
    Jahnke, L.
    Cormack, R.
    Tishler, R.
    Court, L.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2220 - 2220